Delta DVP Slim digital modules
Delta DVP Slim digital expansion modules
Delta DVP Slim digital modules are right-side input, output and mixed I/O expansion units for compatible DVP-S CPUs. When adding machine sensors, adding valve or indicator outputs, or replacing a failed card, start with the channel count, field voltage and output type. See what a PLC does and how PLC input and output modules work for an introduction.
Compare all 18 models
DI means digital input and DO means digital output. Select a model code to open its dedicated page.
Digital input and switch modules
| Model | I/O | Signal type |
|---|---|---|
| DVP08SM11N | 8 DI | 24 V DC, S/S |
| DVP08SM10N | 8 DI | 85–132 V AC, 50/60 Hz, COM |
| DVP16SM11N | 16 DI | 24 V DC, S/S |
| DVP32SM11N | 32 DI | 24 V DC, 40-pin MIL |
| DVP08ST11N | 8 DI | Eight built-in selector switches |
Digital output modules
| Model | I/O | Output type |
|---|---|---|
| DVP06SN11R | 6 DO | Relay, C0–C5 |
| DVP08SN11R | 8 DO | Relay |
| DVP08SN11T | 8 DO | NPN transistor (sinking) |
| DVP08SN11TS | 8 DO | PNP transistor (sourcing) |
| DVP16SN11T | 16 DO | NPN transistor (sinking) |
| DVP16SN11TS | 16 DO | PNP transistor (sourcing) |
| DVP32SN11TN | 32 DO | NPN transistor (sinking), 40-pin MIL |
Mixed input and output modules
| Model | I/O | Input and output type |
|---|---|---|
| DVP08SP11R | 4 DI + 4 DO | 24 V DC input, relay output |
| DVP08SP11T | 4 DI + 4 DO | 24 V DC input, NPN output |
| DVP08SP11TS | 4 DI + 4 DO | 24 V DC input, PNP output |
| DVP16SP11R | 8 DI + 8 DO | 24 V DC input, relay output |
| DVP16SP11T | 8 DI + 8 DO | 24 V DC input, NPN output |
| DVP16SP11TS | 8 DI + 8 DO | 24 V DC input, PNP output |
Choosing the right module for your machine
Count the input signals first. For 24 V DC field signals from devices such as inductive sensors, photoelectric sensors and limit switches, choose an 8- or 16-point SM unit or the MIL connector version for 32 inputs. The DVP08SM10N’s 85–132 V AC rating applies to the field inputs. A 230 V AC signal requires a suitable interface. A pressure switch contact uses a digital input. A continuous 4–20 mA measurement uses an analog input. See analog and digital input differences.
Match the output to the load circuit. With relay outputs, check the per-channel and shared common ratings. With DC transistor outputs, check load current, supply polarity and cabinet temperature. An NPN sinking output switches the load’s negative side. A PNP sourcing output switches its positive side. T and TS have different wiring even when their channel counts match. For sensor and common terminal wiring, see the NPN and PNP guide.
When a machine needs six separate relay commons, check the DVP06SN11R’s C0–C5 layout. A station with a few sensors and valves may need a mixed 4 DI + 4 DO or 8 DI + 8 DO module. The DVP08ST11N sends eight built-in switch states to the CPU as input bits for manual option selection. For a DC valve or coil, check the appropriate diode or manufacturer-specified suppressor, the inductive load rating and fuse selection together.
CPU compatibility, terminals and X/Y addresses
Use the DVP-SS2, DVP-SA2, DVP-SX2, DVP-SV2 and DVP-SE documentation to check the exact CPU code, supported right-side modules, total I/O limit and expansion power budget. Check CPU-supplied module power and field circuit power separately. DC inputs use S/S, AC inputs use COM, and relay outputs use C. Depending on the model, transistor outputs use C or UP/ZP.
Match the connector, cable and terminal board on 32-point models. Delta’s cable guide shows UC-ET010-24A with the UB-10-ID32A input board for DVP32SM11N and the UB-10-OT32A output board for DVP32SN11TN. See Delta DVP/AH I/O cables.
Addressing example. In Delta’s Slim connection example, expansion I/O starts at X20 and Y20 and uses octal numbering. With a DVP08SP11R first, the physical points are X20–X23 and Y20–Y23. The CPU allocates eight addresses for inputs and eight for outputs. X24–X27 and Y24–Y27 have no physical terminals. A DVP08SM11N installed next uses X30–X37. The DVP06SN11R likewise takes up eight Y addresses for six physical outputs. Check the program against the new X/Y map whenever the module order changes.
When routing signal wiring away from power and drive cables, check electromagnetic interference and panel grounding together. For incremental encoders and high-speed pulse output, check the dedicated CPU channels and their frequency ratings. Follow the machine’s emergency stop circuit and safety design for emergency stopping.
Programming software and connection cables
Download the program to the CPU. Open the PLC program in WPLSoft or ISPSoft as supported by the CPU target and software version. With ISPSoft, select the PC driver and communication settings in COMMGR. The DVP14SS211R’s COM1 RS-232 port can be reached from a USB-equipped PC via UC-PRG020-12A or from a PC with a physical RS-232 port via UC-MS030-01A. Match the cable to the port on the actual CPU.
Monitor X/Y bits online in the ladder diagram and compare the labels with the panel drawings. When industrial communications bring those signals into SCADA, update the screen tags if addresses change.
Editor’s Note
Read the full part number. When buying used, ask for photos of the front and side labels, terminal blocks and side expansion connector. A single letter can change the load wiring.
Switch off power before removing or fitting a unit. Disconnect output loads for initial power-up. Check that the CPU sees the module, then monitor each input online.
Test the output under a safe load. With the correct supply and common, check that each output turns on and off. If the relay clicks and the load stays off, check its contact and common.
Check the common if a whole group fails. Use a multimeter to verify the field supply and 0 V reference. Inspect for loose terminals and, on MIL connector models, check for bent pins and confirm ribbon cable orientation.
Record the existing order before removal. Back up the CPU project, photograph the module chain and save the X/Y map. Moving a working module can assign the same physical channel to a different task.
Related topics and OtomasyonAVM PDF archive
Delta DVP expansion modules · Delta DVP PLC series · Slim analog modules · Slim temperature modules · Delta PLC accessories.
Delta PLC main category · Second-hand Delta products.
Delta DVP PLC files · DVP-SA manual in Turkish (PDF).
External references
Delta DVP module manual, chapter 7 · Delta DVP catalogue and ordering table · Delta PLC/HMI cable guide · DVP-Slim instruction sheet and I/O allocation example · DVP08ST11N switch module datasheet.