Delta WPLSoft: DVP PLC programming, downloads and maintenance
Delta WPLSoft is a Windows-based programming application for creating, transferring, reading and monitoring programs on supported DVP-ES2, EX2, SS2, SA2, SX2, SE and other compatible DVP CPUs. It is used for traditional ladder projects and maintenance of existing machines.
The current central record checked on 14 November 2026 is WPLSoft V2.53. Its issue date is 31 July 2025; Delta lists a multilingual package of approximately 83.1 MB. Official WPLSoft V2.53 download opens Delta’s terms/verification page. Check the WPLSoft Download Center for later releases.
Supported hardware and exclusions
Select WPLSoft using the complete CPU code and matching project PLC type. Instruction and memory support in DVP-EH3 and DVP-SV2 must not be assumed identical to smaller DVP CPUs. WPLSoft is not the programming environment for AS or AH controllers; select ISPSoft or DIADesigner as required by the model.
Do not select WPLSoft for DVP-ES3, ES300TEC, EX3, SV3 or SX3. Page 16 of the manufacturer hardware manual identifies ISPSoft/DIADesigner for standard ES3 and DIADesigner only for ES300TEC/EX3/SV3/SX3. DVP-PM motion controllers require PMSoft and their model-specific documentation.
The current download record also lists TP04P/TP70P and VFD-E, C200, C2000/CH2000/CT2000, CP2000, MS300, MH300, VHVAC, LTC and MP drive families. This concerns supported built-in PLC functionality. Panel display design and complete drive parameter configuration are separate tasks; check TPEditor and the model-specific display tool as required.
Ladder, instruction and SFC editing
WPLSoft provides ladder, instruction and SFC editing. X/Y I/O, M auxiliary relays, S step relays, T timers, C counters and D data registers must stay within the selected CPU’s supported ranges. For a project requiring ST or FBD, do not assume WPLSoft provides the same features as ISPSoft.
Compilation, online monitoring and reading device values are different operations. For analogue modules, high-speed counting, positioning or serial commands, consult the DVP instruction manual and the exact CPU support table. Availability of an instruction in the editor does not establish support on every DVP controller.
Communication and the COMMGR distinction
WPLSoft includes its own communication settings. A separate COMMGR installation is not universally required for WPLSoft. Do not apply the ISPSoft+COMMGR workflow unchanged. Select serial, USB virtual COM or Ethernet according to the CPU; an appropriate USB driver and PLC programming cable may still be required.
Match COM assignment, station address, baud rate, parity and protocol. DCISoft can assist with supported Ethernet devices. An RJ45-shaped connector is not necessarily Ethernet; drive ports may carry serial communication. Confirm the electrical interface and pinout in the device manual.
Legacy projects, .dvp files and version selection
WPLSoft uses .dvp project files. Delta’s V2.30 announcement explicitly states that the file format changed and earlier versions cannot open projects saved by V2.30. Preserve an untouched original before saving a copy in a newer editor, and record the WPLSoft version alongside the project.
Manufacturer records identify older releases including 2.20.11, 2.30, 2.31, 2.33, 2.36, 2.40 and 2.42. Later support records mention 2.48–2.51, while the current central search lists 2.52 and 2.53. These are not separate CPU licences. The HMI-WPLSoft document for DOP-EXIO14RAE/DOP-EXIO28RAE must not be presented as the current general V2.53 user manual.
Supported WPLSoft .dvp files can be opened in ISPSoft and saved as .isp. Full reverse conversion is not established for every feature. After opening an older project in a newer editor, compare CPU selection, compilation, comments and machine functions.
Windows and simulation
The manufacturer OS field for V2.53 reads Windows XP/Vista/7 (32-bit/64-bit)/8/10 (64-bit)/11 (64-bit). Delta Türkiye also identifies Windows 11 compatibility in its V2.52 support reply. An older CD installer must not be assumed to provide the same support. Delta identifies Windows as the native environment rather than providing a native Linux/macOS version.
Simulation helps test logic without a PLC, but does not reproduce every physical I/O, network or motion function. Timer/counter execution can depend on the PC, and some instructions are unsupported in simulation. A successful simulated run does not replace testing on the actual controller.
PDF documents
Use the application’s Help menu for current editor help. The documents below provide instruction references, applications and historical release comparisons; they are not all V2.53 interface manuals.
DVP-PLC programming and instruction manual — Ladder execution, instructions, SFC and device memory for supported legacy DVP CPUs. An instruction reference, rather than a replacement for the editor help. English; 2017-06-15; 747 pages; 12.03 MiB.
DVP-ES2/EX2/SS2/SA2/SX2/SE and TP programming — 2013 edition: model-specific instructions, special relays/registers and WPLSoft examples. It is not assumed to cover later EC5/SE2 devices. English; 2013-02-20; 782 pages; 12.03 MiB.
TP70P quick start with WPLSoft example — PLC programming with WPLSoft 2.36, panel design with TPEditor and connection examples. Historical edition, not a universal guide for all current panel revisions. English; 2014-10-31; 65 pages; 2.69 MiB.
WPLSoft V2.40 technical announcement — Original four-page manufacturer release note covering editor and memory-card fixes. It is not the current release announcement. English; 2015-04-23; 4 pages; 0.14 MiB.
Software selection for newer DVP families — Printed 1-2/PDF16: WPLSoft is not the editor for ES3; ES300TEC/EX3/SV3/SX3 require DIADesigner. Preserves the filename used in the previous shared archive. English; 2023-12-12; 489 pages; 13.08 MiB.
WPLSoft/ISPSoft tools for built-in drive PLCs — CP2000/CFP2000 application. Its software section distinguishes WPLSoft integrated communication settings from ISPSoft+COMMGR. Preserves the previous filename. English; 2023-09-20; 66 pages; 1.51 MiB.
Editor’s Note
Start by matching the complete CPU code to the PLC type in the project. Establishing a connection alone does not confirm that the correct program and CPU have been selected.
Preserve the original .dvp file and its WPLSoft version. Test a newer editor on a copy rather than overwriting the only project you have.
If the PLC is not visible, check the driver, COM number, station address and serial settings in order. Matching connectors do not make RS-232, RS-485 and Ethernet interchangeable.
Identify a D register before changing it: it may contain a process setting, counter data or a communication parameter. Program backups and records of important register values meet different needs.
Force ON/OFF and manual register writes can affect physical outputs and machine movement. Use the machine’s controlled test procedure and check forced states afterwards.
After simulation, verify real inputs, outputs, alarms, power-cycle behaviour and communication, recording the results with the project.
Related topics
Delta PLC software · Delta ISPSoft · Delta COMMGR · Delta PMSoft
Delta CANopen Builder · Delta TPEditor · Delta LCSoft · Delta DCISoft
Delta DeviceNet Builder · Delta DVP-ES2 · Delta DVP-EX2 · Delta DVP-SS2
Delta DVP-SA2 · Delta DVP-SX2 · Delta DVP-SE · Delta DVP-EH3
Delta DVP-SV2 · Delta Plc Cables · Delta PLC and hmi manuals · Delta PLC 2
External references
Delta Download Center · Delta Türkiye WPLSoft · WPLSoft V2.30 · Windows / Linux FAQ