Delta DVP-SX2

Delta DVP-SX2: Slim PLC with Built-in Analog Inputs and Outputs

Delta DVP-SX2 is a standalone PLC CPU within the Delta DVP PLC series range, combining digital control and analog measurement. It contains 8 digital inputs, 6 digital outputs, 4 analog inputs and 2 analog outputs. Program capacity is 16k steps, with 10,000 data-register words. It can be considered for pressure, flow, level and temperature control with suitable signal conditioning.

The PLC requires 24 V DC, with a specified supply range of 20.4–28.8 V DC. Its built-in analog channels do not make it an expansion module: the SX2 CPU executes the control program. Additional functions require compatible Delta DVP expansion modules.

DVP20SX211R, DVP20SX211T and DVP20SX211S

DVP20SX211R has relay outputs. DVP20SX211T uses NPN transistor outputs, while DVP20SX211S uses PNP transistor outputs. All three retain the 4AI/2AO arrangement. The R/T/S suffix changes output wiring and electrical behaviour; check existing field connections before changing models.

On transistor versions, Y0 and Y2 support up to 100 kHz, while Y1 and Y3 support up to 10 kHz pulse output. All six outputs are not rated for 100 kHz, and these pulse capabilities do not apply to the relay version. Check output polarity, common terminals and drive-input requirements when connecting a pulse-controlled drive.

Programming software

The SX2 can be programmed with Delta WPLSoft or Delta ISPSoft. Select the correct SX2 CPU type and check instruction support against CPU firmware and software version. Delta COMMGR manages the communication connection for ISPSoft; it is not a PLC program editor. See Delta PLC software for the roles of the available tools.

Programming cables, USB driver and connection

USB connection: use a data cable matching the PLC’s Mini-B USB socket; a USB-A–Mini-B cable suits a conventional USB-A computer port. The PLC also needs its 24 V DC supply. Install the USB driver and identify the assigned COM port in Windows Device Manager. Because the SX2 contains a USB-to-RS-232 circuit, select RS232 as the COMMGR driver type. This is described in sections 2-61 and A-20 of the ISPSoft user manual.

RS-232 connection: the DVPACAB2A30 cable connects the PLC’s COM1 8-pin Mini-DIN port to a computer’s 9-pin D-sub serial port. A suitable USB-to-RS-232 adapter and its driver are also needed when the computer has no serial port. A USB-to-TTL lead is not a substitute. Refer to Delta PLC cables and Delta PLC accessories when selecting connection hardware.

Select the correct COM port and matching PLC communication parameters in COMMGR, then select that connection in ISPSoft. Configure the relevant serial port and parameters in WPLSoft when using that editor. The SX2 includes RS-485 communication but has no built-in Ethernet port. For applications prioritising Ethernet, also review Delta DVP-SE.

Analog channels and PID applications

The built-in analog inputs and outputs have 12-bit resolution. Input modes include ±10 V, ±20 mA and 4–20 mA; output modes include ±10 V, 0–20 mA and 4–20 mA. Terminal wiring and the configured channel mode must agree. 12-bit resolution does not mean that every mode uses a raw range of 0–4095. Apply the numerical conversion range specified for the selected mode.

Analog input values use D1110–D1113; analog output values use D1116–D1117. D1115 configures channel modes, and D1118 relates to sampling time. There is no galvanic isolation between the analog and digital circuits, so common-reference and shielding connections matter. Verify measurement accuracy and output direction before tuning a PID loop.

Expansion and related series

The SX2 supports compatible left-side and right-side Slim expansion modules. Check each module’s complete code, mounting side and power requirements. Delta DVP-SX, Delta DVP-SS2, Delta DVP-SA2, Delta DVP-SV2 and Delta DVP-EX2 provide other CPU and I/O arrangements; they should not be assumed to be direct replacements.

Editor’s Note

When buying a used SX2, do not judge it from the POWER indicator alone. Check whether the program can be read, then test the digital I/O and analog channels separately.

Back up the existing machine program, accessible parameters and required retained data before downloading a replacement project. Losing the machine settings can create more work than replacing the PLC itself.

Disconnect analog inputs from field wiring and test low, middle and upper points with a suitable calibrator. Record channel differences; one correct reading does not prove accuracy across the entire range.

Measure analog outputs with suitable test loads as well. Confirm voltage/current mode and the meter connection before testing, especially when measuring current.

If USB communication fails, check the data cable, driver, COM number and RS232 selection in COMMGR first. Also inspect the socket and verify supply stability.

Possible checks include welded relay contacts, transistor-output voltage drop under load and analog offset. These are diagnostic checks, not faults guaranteed to occur on every SX2. Disconnect power before board work and narrow down the fault by measurement.

PDF documents and related topics

Use Delta DVP PLC files for series documents. Read the Delta ISPSoft and Delta COMMGR pages together when setting up communication.

Related topics: Delta PLC accessories · Delta DVP expansion modules · Delta PLC software.

Navigation: Delta DVP PLC series · Delta PLC category · Used Delta equipment · DVP files.