Delta DVP-SV2 PLC series

Delta DVP-SV2 is a second-generation Slim PLC CPU family within the DVP PLC range, intended for high-speed counting and pulse positioning applications. It executes the machine control program in packaging, labelling and similar equipment. The series uses a 24 V DC supply and provides 30,000 program steps.

DVP-SV2 models and output types

DVP28SV11R2: 16 digital inputs and 12 relay outputs. Relay contacts are for switching loads and cannot provide high-speed servo/step pulses.

DVP28SV11T2: 16 digital inputs and 12 NPN transistor outputs. Select the designated fast outputs and match them to the drive input circuit.

DVP28SV11S2: 16 digital inputs and 12 PNP transistor outputs. Output commons and field wiring must be reviewed when replacing an NPN unit.

DVP24SV11T2: 10 digital inputs, 12 NPN transistor outputs and 2 analog inputs. The analog channels accept 0–10 V or 0–20 mA; resolution is 12-bit for voltage and 11-bit for current. This analog specification does not apply to the other three models.

Which software programs the DVP-SV2?

DVP-SV2 can be programmed with WPLSoft and ISPSoft. WPLSoft handles traditional ladder projects; ISPSoft provides project and program organisation. Select the appropriate SV2 CPU family in the software. Record the original project's engineering tool and version when preparing a maintenance computer.

For an ISPSoft connection, create the appropriate serial communication channel in COMMGR. COMMGR is a communication manager, not a PLC program editor. The engineering software, communication manager and Windows driver for a USB converter are separate components. See Delta PLC software for installation and documentation links.

Programming cable and PC connection

The standard programming connection uses COM1 RS-232. The DVPACAB2A30 is an approximately 3 m Delta cable with a 9-pin female D-sub connector at the PC end and an 8-pin mini-DIN connector at the PLC end. See Delta PLC programming cables for cable information.

If the PC has no serial port, use PC USB → USB-to-RS-232 converter with its driver installed → DVPACAB2A30 → PLC COM1. The DVP-SV2 has no built-in USB programming port; a normal USB cable cannot connect directly. A USB-to-TTL adapter is not a substitute for an RS-232 converter.

Select the actual Windows COM number in the software. Station address, baud rate, data bits, parity and stop bits must match the existing PLC configuration. Close other applications using the port. Do not change a working machine's communication settings merely to try a connection.

High-speed counting, pulse output and motion

The series provides four hardware 200 kHz high-speed counters and, on suitable transistor models, up to four axes of 200 kHz pulse output. Linear and circular interpolation functions are supported. DVP24SV11T2 also provides 10 kHz output capability through Y10/Y12. Check hardware revision and counting mode for input speed, and the output pairs used by each motion instruction.

The catalogued 0.24 µs basic instruction time is not the scan time of the complete application. Evaluate encoder electrical signals, pulse shape, cabling and input filtering together.

Expansion and communication

COM1 is RS-232 and COM2 is RS-485. There is no built-in Ethernet port. For Ethernet projects, review compatible Slim communication modules and solutions such as DVPEN01-SL, including CPU, firmware and protocol requirements.

Within the DVP expansion range, Slim digital, Slim analog and Slim temperature modules serve different functions. Suitable expansion can increase the digital I/O system to 512 points in total. This does not imply unlimited module count or power capacity: check left/right bus compatibility, module limits and the supply budget separately.

Editor's Note

Start with the complete nameplate code. The R2, T2 and S2 suffixes change the output circuit; identical housings do not justify identical wiring.

On an operating machine, back up the program and required retained data first. Record port settings and the status of the existing Flash backup. Saving a PC project and updating the PLC's permanent backup are separate operations.

Check the 24 V supply under load before blaming the CPU. If an output LED is on but the load does not operate, inspect field power, commons, wiring and the load before testing relay contacts or the transistor output stage.

A multimeter alone cannot confirm a high-speed pulse output. Prevent machine motion safely and use an oscilloscope or suitable counter. Do not force arbitrary outputs to try a servo connection.

Do not ignore BAT.LOW or replace the rechargeable backup battery with an ordinary coin cell. The manual specifies more than 24 hours of power for a full charge. If the warning persists, preserve the program and data and have the battery/charging circuit serviced.

For a used PLC, a RUN light is only the starting point. Have all inputs, outputs, both communication ports and data retention after a controlled power cycle tested. Motion applications also require separate testing of the high-speed channels.

PDF manuals

Use our Delta DVP PLC files page for hardware, wiring and programming documentation. Distinguish SV2 from the earlier SV generation; similar family names alone are not sufficient grounds for selecting a manual.