Delta PLC Accessories — Power, Connections, Memory and Field Hardware
Delta PLC accessories support control-system power, computer connections, field wiring and auxiliary functions. The group includes DVP, AS and AH power supplies; backplanes, interfaces, programming and I/O cables, external terminals, memory accessories and training kits. Start by identifying the complete CPU model within the Delta PLC family and the function of the module being connected.
A connector that fits does not establish compatibility. Verify the electrical interface, pin assignment, power requirements, supported device and any protocol involved. Accessories within the Delta brand should not be assumed interchangeable across DVP, AS and AH systems.
DVP, AS and AH power supplies
Within Delta DVP power supplies, DVPPS01 provides 24 V DC / 1 A, DVPPS02 24 V DC / 2 A and DVPPS05 24 V DC / 5 A. Calculate the current budget for the PLC, modules and field loads sharing the supply, and check cabinet temperature and the manufacturer’s loading conditions.
Delta AS power supplies distinguish internal system power from external-load power. AS-PS02 provides 24 V DC / 2 A for internal PLC use. AS-PS02A specifies 1.5 A for internal use and 0.5 A for external use. These capacities must not be treated as an unrestricted 2 A available from a single output.
Among Delta AH power supplies, AHPS05-5A is an AC-input option and AHPS15-5A a DC-input option for rack power. Check the power budget of backplane modules separately from field-sensor and actuator supplies. Similar output power alone does not establish replacement suitability.
AH Motion backplanes and system layout
Delta AH Motion backplanes provide the base/backplane for the CPU and compatible modules. When selecting a unit such as AHBP03M2-5A, consider the motion CPU, available module slots and power unit together. The backplane is not itself a motion CPU generating axis commands; slot count alone does not establish support for every module.
Interfaces, programming and communication cables
Delta DVP interfaces perform different computer, serial-line and network duties according to the model. Distinguish electrical-interface conversion from protocol conversion. Having RS-232, RS-485, USB or Ethernet connections on a device does not establish support for every required data exchange.
Select DVP programming cables and DVP communication cables for the actual port duty. For example, UC-PRG015-01A uses mini USB, while UC-PRG015-02A uses USB Type-B. Match the USB driver, target device, serial settings and pin assignment to the existing project. Select tools under Delta PLC software according to the CPU family as well.
I/O cables and external terminals
When choosing Delta DVP / AH I/O cables and Delta AH I/O cables, verify the complete module → cable → terminal connection. Pin count, signal direction, commons, shielding and cable length matter. Two cables with the same number of pins may have different internal wiring.
Explore Delta external terminals and Delta AH external terminals for field-wiring arrangements. Match relay, transistor-output and input-terminal types to their intended modules. Adding an external terminal does not automatically add PLC I/O addresses. Increasing the channel count requires a separate selection of expansion hardware supported by the CPU.
CANopen, EtherCAT and industrial network connections
Choose Delta CANopen cables, Delta EtherCAT cables and Delta industrial network cables for the intended network. For Delta network connectors, check pin assignments, shield connections, termination and topology. An RJ45 connector alone does not identify the protocol or establish suitability for every network.
Memory, batteries and other accessories
Delta DVP memory accessories includes products such as DVP-512FM and DVPPCC01. Distinguish program backup/copying from increasing the CPU’s working memory; verify the supported CPU and the data that can be transferred. Select distribution, connection and termination products under Delta DVP other accessories for their specific functions.
For battery accessories such as DVPABT01, check voltage, chemistry, polarity, connector and intended device together. Follow the manufacturer’s replacement procedure after backing up the program and necessary retained data. Matching physical size alone does not establish battery suitability.
Training kits and included equipment
Delta DVP training kits provide a starting point for learning PLC, operator-panel and connection applications. For a used kit, confirm which CPU, HMI, power supply, cables and example projects are included. A catalogue kit name alone does not establish that every original component is present in the offered package.
Editor’s Note
Start with a short connection list: Which CPU, which port, which module and which terminal? Obtain clear photographs of labels and connectors. This preparation helps prevent a wrong cable from being mistaken for a board fault.
A no-load voltage reading is insufficient to establish power-supply health. Have voltage and stability checked with a suitable test load. For unexpected resets, investigate supply dips and connections first. Keep internal-system and external-load capacities separate when calculating demand.
If the computer cannot find the device, check the USB driver, selected port, cable and target device in sequence. A visible USB connection does not prove that the RS-485 settings or protocol on the other side are correct.
Inspect I/O cables for crushing, sharp bends and loose latches. Perform continuity tests with the cable disconnected from electronic devices and using the correct pin diagram. If many channels fail together, investigate common and terminal connections too.
On used backplanes and terminals, look for bent pins, corrosion, broken catches and overheating marks. An intermittently disappearing module may have a power or mechanical-contact problem; investigate these separately from the program.
Back up a working system before replacing a memory card or battery. Do not test an unknown card by inserting it into a sound machine. Establish its program, parameter and retained-data scope, then follow the manufacturer’s insertion/removal procedure.
Confirm more than the main item when buying. Establish which terminals, adaptors, cables and mounting parts are included. A missing small component can delay commissioning even when the main accessory was selected correctly.
PDFs, software and technical documents
Use Delta PLC accessories files as the shared document page. Check electrical limits for power units, pin diagrams for cables, supported protocols for interfaces and CPU support for memory accessories. Explore Delta PLC and HMI manuals for other document groups.
Related topics and navigation
Select accessories together with the complete CPU code, module type, hardware revision and existing machine project. Category names help locate products; use the model’s own technical document for the final selection.
External references
Delta DVP/TP manufacturer catalogue — 2024, English, Mouser-hosted copy · Delta AS Hardware and Operation Manual — English · Delta AH Motion Hardware Manual — English