Delta DVP interfaces

Delta DVP Interfaces and Communication Converters

Delta DVP interfaces cover IFD converters and gateways used between computers, PLCs, drives and field networks. This group under Delta PLC accessories includes different functions for USB, RS-232, RS-422, RS-485, CAN, DeviceNet, CANopen and Ethernet. Select the interface against the devices and protocols at both ends.

Electrical interface converters, repeaters and protocol gateways are different device types. Providing USB–RS-485 connectivity is different from converting Modbus RTU to Modbus TCP. These products are not PLC CPUs or general-purpose I/O expansion modules.

IFD models and functions

Model Main function
IFD6500 USB ↔ RS-485 converter
IFD6503 USB ↔ CAN interface
IFD6530 USB ↔ RS-485 interface for C2000
IFD8500-A Isolated RS-232 ↔ RS-422/RS-485 converter
IFD8510-A Isolated RS-422/RS-485 repeater
IFD8520 Addressable RS-232 ↔ RS-422/RS-485 interface
IFD9502 DeviceNet–Modbus gateway
IFD9503 CANopen–Modbus gateway
IFD9506 Serial–Ethernet; Modbus TCP and version-dependent EtherNet/IP
IFD9507 Legacy EtherNet/IP model with RS-232/RS-485 interfaces

Assess IFD6530 for its C2000 drive application; the manufacturer specifies a 9 V power-supply function. Do not treat this as a general PLC supply or standard 24 V field connection. Use the correct model documentation for suffix differences such as IFD8500 and IFD8500-A.

Serial interfaces versus protocol gateways

RS-232, RS-422 and RS-485 specify electrical interfaces; data format and application protocol must also match. A repeater regenerates the existing signal without independently changing register maps or protocols. A gateway requires configuration of communication roles and data mapping on both sides.

When selecting DVP programming cables and DVP communication cables, check interface ports, pin assignments and direction. Select CANopen cables and network connectors against the electrical rules of the relevant network.

IFD9506: Modbus TCP and EtherNet/IP

The IFD9506 manual describes Modbus, Modbus TCP, EtherNet/IP and UD Link modes between RS-232/RS-485 and Ethernet. EtherNet/IP Adapter mode requires firmware V2.04 or later and EIP Builder V1.07 or later. Do not assume that an older unit supports every mode from its model name alone.

The specified IFD9506 configuration tool is Delta DCISoft. Match the IP address, serial settings, operating mode and data table within the project. An Ethernet link or successful ping alone does not establish correct PLC data exchange.

Drivers, software and project preparation

For USB models, verify the correct device driver, operating-system support and application connection. Assess Delta COMMGR for communication links and Delta ISPSoft for supported PLC projects; the same tool does not configure every IFD model.

Delta CANopen Builder and Delta DeviceNet Builder provide references for the relevant network tools. Determine the required tool from the device manual. USB drivers, device-description files and PLC programs serve different purposes during commissioning.

Legacy models and replacement assessment

The manufacturer lists IFD9507 as discontinued in December 2019, with IFD9506 identified as its replacement. It lists IFD9502, IFD9503 and IFD8520 as discontinued in June 2024. Preserve the correct manuals, configuration backups and project files for installed equipment.

A manufacturer replacement listing does not establish that existing cables and projects can be transferred without checking. Compare supply requirements, terminals, network roles, protocols, firmware and PLC data mapping. In particular, an electrical converter and an addressable interface must not be treated as performing the same application function.

Wiring and field checks

Verify the device supply, USB-powered or externally powered arrangement, and electrical port ratings before commissioning. Check baud rate, parity, data/stop bits and station address on serial links; IP and subnet settings on Ethernet; and node identity and bit rate on CAN-based networks. Apply termination and shielding according to the relevant network manual.

Editor's Note

Write down what each end needs to do first: connect a computer to a PLC, expose serial equipment to Ethernet, or extend a physical link. Choosing one converter for all three tasks can leave you without communication even when the hardware is healthy.

For USB devices, first confirm that the computer recognises the hardware correctly. Establish the driver and cable connection, then select the application port. Also check whether another program is already using the connection.

For RS-485, compare D+/D−, signal reference and the actual wiring drawing. A/B naming can vary between manufacturers, so do not transfer labels from memory. Isolate the link safely and inspect for shorts, open circuits and loose terminals.

A successful Ethernet ping is not the final test. Read several known registers and verify data types, address offsets and word order. Incorrect mapping can pass apparently valid communication while delivering wrong machine values.

Record configuration and firmware before removing an old unit. When changing from IFD9507 to IFD9506, verify operating mode and supported-version requirements. Validate the connection under controlled conditions rather than transferring old settings blindly.

Do not accept a used interface solely because its LEDs illuminate. Test data exchange in both directions with suitable equipment and observe operation long enough to reveal intermittent faults. Corroded connectors, weak supplies and damaged shielding can also cause communication dropouts.

PDF and software files

The document hub is Delta PLC accessories files. Consult Delta PLC and HMI manuals and Delta user manuals for further documents. General IFD introductions and model-specific manuals can contain different levels of detail; use the complete model’s manual for version-dependent requirements.

Related topics

Delta DVP PLC series · Delta AS PLC series · Delta AH PLC series

Navigation: Delta PLC accessories · Delta PLC main group · Used Delta products

External references

Delta IFD series function descriptions · IFD9506 operation manual — English · Delta Industrial Fieldbus Solution — products and legacy models


Refine Search