Delta network connectors
Delta Network Connectors
Delta network connectors provide cable connections and, depending on the model, network termination. This group under Delta PLC accessories includes the UN-03EN-04A RJ45 adapter and UN-03PF-01A, UN-03PF-02A and UN-03PF-03A PROFIBUS connectors. Select them against the actual device port and network arrangement.
These parts do not independently add a communication protocol to a PLC. Passive connection accessories, active communication modules, gateways and Ethernet switches have different roles. The installation must already contain a port or module supporting the required protocol.
Models in this group
Delta UN-03EN-04A: an RJ45 adapter shown in the manufacturer’s DMCNET wiring arrangements. Do not treat its connector shape as evidence that it functions as an Ethernet switch.
Delta UN-03PF-01A: a male DB9 PROFIBUS connector. Compare cable routing and enclosure clearance with the installation requirements.
Delta UN-03PF-02A: provides a male DB9 PROFIBUS connection plus a female DB9 programming connection. Do not treat the additional socket as a general RS-232 port.
Delta UN-03PF-03A: a male DB9 PROFIBUS connector. When considering replacement of an 01A, compare the housing, cable exit and mounting space against the relevant drawings.
Why connector shape is insufficient
An RJ45 housing can be used for Ethernet, EtherCAT or another communication arrangement. Review Delta industrial network cables, EtherCAT cables and CANopen cables separately. Verify pin assignments, signal type, shielding and topology before connecting equipment merely because the plug fits.
A DB9 connector likewise does not establish an RS-232 interface. When selecting PROFIBUS wiring, consult Delta DVP communication cables alongside the connected device’s port documentation. Label A/B conductors, shielding and cable entry/exit directions before installation.
PROFIBUS termination and network arrangement
The manufacturer’s UN-03PF table specifies termination switches ON at network ends and OFF at intermediate positions. Set termination according to the connector’s physical position in the network; enabling it at every connector is incorrect.
Recheck the physical endpoints after removing a device or changing the wiring. Read the model-specific drawing to establish how a switched connector routes its incoming and outgoing cables. Network length and speed limits depend on the complete cable and device arrangement, rather than the connector code alone.
Distribution boxes and terminators
TAP-CN01, TAP-CN02 and TAP-CN03 are CANopen/DeviceNet distribution accessories. TAP-TR01 is a terminator for the relevant network. Match distribution boxes, connectors and terminators to their respective network and wiring functions.
Software and commissioning
Passive connectors do not receive a downloaded program; suitability depends on their electrical connections and mechanical construction. Tools such as Delta ISPSoft and Delta COMMGR apply according to the connected active device. Selecting the correct software port does not correct physical wiring errors.
Editor's Note
Before replacing the PLC or communication card, inspect the connector, loose screws, broken latches and trapped cables. A cabinet door pressing against a cable can eventually damage an otherwise sound connection.
Photograph the complete model code, cable entry direction and termination-switch position before removal. Once the connector is off, identifying the original endpoint or intermediate position can waste valuable time if nothing was recorded.
Do not insert an arbitrary network splitter simply because the socket is RJ45. Establish the protocol and pinout first. Matching connector shapes do not establish matching electrical signals.
For intermittent contacts, stop the system safely, disconnect the wiring and perform de-energised continuity and short-circuit checks. Gently move the cable while checking for a changing fault. Passing a continuity test alone does not establish good signal quality at operating speed.
Do not change PROFIBUS termination switches randomly. Record the original positions before testing, so that each change remains traceable. After repairing a connection, observe communication under normal operating load for a sufficient period.
Inspect used connectors for bent pins, corrosion, poor shield contact and damaged cable clamps. A glued housing with a failed retaining mechanism is not a durable repair. Replace damaged parts appropriately and verify the complete link again.
PDF and software files
The document hub for this section is Delta PLC accessories files. Use Delta PLC and HMI manuals and Delta user manuals for further references. In the cable selection guide, consult section 3.2 for UN-03EN-04A, section 4.2.2 for PROFIBUS connectors, and Appendix A.
Related topics
Delta DVP PLC series · Delta AS PLC series · Delta AH PLC series · Delta DVP interfaces · Delta DVP programming cables
Navigation: Delta PLC accessories · Delta PLC main group · Used Delta products
External reference
Delta PLC/HMI Cable Selection Guide — English manufacturer manual hosted by DigiKey