Delta UN-03PF-02A — PROFIBUS DB9 Connector with Programming Socket

Delta UN-03PF-02A is a PROFIBUS DP connector with a male DB9 device connection and an additional female DB9 programming/service socket. It belongs to the Delta network connectors range, connecting the PROFIBUS cable to the device port while providing access for suitable service equipment.

Purpose of the programming socket

The additional socket provides a connection point for a compatible PROFIBUS PG/PC adapter or diagnostic device. A DB9 connector alone does not establish RS-232 compatibility. Station addresses, device parameters and network configuration are set in the relevant PROFIBUS equipment.

Connection specifications

Item UN-03PF-02A
NetworkPROFIBUS DP, RS-485 physical layer
Device connectionMale DB9
Programming / service connectionFemale DB9
TerminationSwitchable bus termination

Review UC-PF01Z-01A for the PROFIBUS cable. Other connections are covered under Delta industrial network cables. Check cable diameter, shield connection and the connector’s cable-retaining arrangement.

Basic PROFIBUS DB9 pin functions

Pin / part Signal Function
3RxD/TxD-P · BData +; standard colour red
8RxD/TxD-N · AData −; standard colour green
5DGNDData reference potential
6VP+5 V on the standard PROFIBUS DB9 interface; used for termination power
HousingShieldCable-shield connection

Read pin numbers using the correct connector viewing direction. Check A/B and P/N markings alongside conductor colours. Do not use VP as a 24 V field-supply input. Confirm other pin functions in the connected equipment’s manual.

Termination switch and cable shield

Switch termination ON at both ends of each PROFIBUS segment and OFF at intermediate stations. Excess termination can disrupt communication. At a segment end, check incoming/outgoing cable markings: on some connector types, the termination switch also disconnects the outgoing cable.

Make a broad contact between the cable shield and the connector’s shield connection. Prevent exposed shield strands from touching data terminals. Assess cable length together with data rate; the connector alone does not define the permitted network distance.

Programming-socket differences in the UN-03PF family

Model Device connection Programming socket
UN-03PF-01AMale DB9None
UN-03PF-02AMale DB9Female DB9
UN-03PF-03AMale DB9None

Allow room for the service adapter when selecting UN-03PF-02A. Check that the connector body and cable do not press against the panel door or adjacent equipment.

Related Delta PROFIBUS equipment

Delta’s PROFIBUS DP guide lists AH10PFBM-5A as a master, AH10PFBS-5A as a slave, and AHRTU-PFBS-5A for remote I/O. Review these under Delta AH PLC series and AH communication modules.

For Delta DVP PLCs, the guide includes DVPPF01-S, DVPPF02-SL and DVPPF02-H2, alongside the RTU-PD01 remote terminal. Verify the actual device port, pin assignment and mechanical access when selecting the connector.

Editor’s Note

The additional programming socket distinguishes 02A. If using a service adapter, inspect this socket as well as the main DB9 plug and check that sufficient access space remains.

Photograph A/B conductors before disconnecting them. Follow both colours and markings on the replacement connector. Reversed data conductors can waste time troubleshooting software settings.

Use the intended shield-contact area rather than reducing the braid to a thin wire at one point. Ensure strain relief grips the outer cable jacket. Loose housings or crushed cable entries can cause vibration-related faults.

Do not switch termination ON at every station. Identify both segment ends before checking intermediate nodes. When removing an end device, consider how termination and its required power will be maintained.

Safely isolate the segment before measurement and record switch positions. Check for broken conductors, shorts and unintended contact with the shield. Restore cable direction and termination settings afterwards.

On a used connector, inspect DB9 pins, screw threads, covers and the switch. Follow continuity checks with actual data exchange and stable communication using suitable PROFIBUS equipment.

PDF and related topics

Use the Delta PLC accessories PDF and software files page for connection documents. Further documentation is available under Delta PLC and HMI manuals and Delta user manuals.

Navigation: UN-03PF-02A main page · Delta PLC accessories · Delta PLC models · Used Delta products

External references

Delta PLC/HMI Cable Selection Guide — 4-9 / 4-10 · PROFIBUS & PROFINET International — 9-pin Sub-D Connection · PROFIBUS & PROFINET International — Assembling PROFIBUS Cables