Delta UN-03EN-04A

Delta UN-03EN-04A – RJ45 adapter for terminator connections

Delta UN-03EN-04A is a passive RJ45 adapter that allows a suitable terminator to be connected alongside the communication cable. The manufacturer's cable selection guide shows an arrangement with one male RJ45 connector and two female RJ45 connectors. Delta Türkiye's product table identifies it as an accessory providing an additional connection for the TAP-TR01 terminator. It belongs to the Delta network connectors group.

Function and connector arrangement

The UN-03EN-04A allows a network cable and a termination plug to share a suitable device port. The adapter and the terminating resistor are separate components. Installing the adapter alone does not terminate the network correctly. Its two female connectors do not create two independent Ethernet connections. It is not an Ethernet switch, signal repeater or protocol converter.

RJ45 describes the connector format; it does not identify the communication protocol. Follow the connected device's port definition, signal assignments and wiring diagram. Applications requiring active Ethernet-to-serial conversion should be assessed using a separate device such as the Delta IFD9506. The UN-03EN-04A has no IP address, communication driver or user program to configure. Any Delta ISPSoft work concerns the connected PLC.

CANopen and DMCNET termination

CANopen application: Delta Türkiye associates the adapter with the TAP-TR01, whose terminating resistance is specified as 121 Ω. Check the required resistor, the actual network endpoints and any built-in termination together. Delta CANopen cables and the TAP-CN03 distribution box perform different jobs within the installation. The adapter, cable and distribution box are separate component types.

DMCNET application: the Delta PLC/HMI Cable Selection Guide shows the UN-03EN-04A adding a terminator at the beginning of a network in its AH20MC-5A example. That example specifies a 150 Ω TAP-TR02. Do not substitute the TAP-TR01 listed for CANopen for this DMCNET termination component. Determine termination locations and quantity from the actual controller manual and network arrangement.

Compare the model and length information for UC-CMC003-01A, UC-CMC010-01A and UC-CMC020-01A when selecting a cable. Connector fit alone is insufficient: shielding, pin assignments and the installation rules for the specific network must also agree.

Device compatibility and other UN connectors

For a CANopen system containing a DVP10MC11T or DVPCOPM-SL, start with the relevant device's network wiring diagram. For AH installations, consult the documentation under Delta AH motion controllers and Delta AH PLC series. A mechanical fit does not establish compatibility with every RJ45 port.

The UN-03PF-01A, UN-03PF-02A and UN-03PF-03A belong to the PROFIBUS connector group. The UN-03EN-04A is an RJ45 adapter. The shared “UN” prefix does not make their interfaces or functions interchangeable. Select the appropriate component group under Delta PLC accessories.

Editor's Note

First establish whether you need the adapter or the terminator. An empty UN-03EN-04A does not complete network termination. Read the termination plug's model separately; the documented CANopen and DMCNET examples use different resistors.

Do not treat every RJ45 connection as a computer network port. Check the port marking and device manual. This adapter is intended for the documented cable-and-terminator arrangement; it does not split an Ethernet link into two independent device connections.

Inspect the latch and contacts on used parts. A broken latch, recessed contact or oxidized surface can cause intermittent communication under vibration. Check that each plug seats securely and support the cable so its weight does not pull on the device socket.

Check contacts with power removed and the components disconnected from the equipment. Continuity and unintended-short checks against the correct pin reference can help identify a poor connection. Do not measure resistance on an energized communication port or assume an undocumented pin mapping.

Record the network arrangement before adding another connection. Identify its actual ends, installed terminators and any internal device termination. Preserve the topology permitted by the manufacturer; an unused socket is not permission to add a branch.

Monitor communication during normal machine operation after replacement. A successful initial connection is only the first check. Watch error counters during motion, cabinet vibration and normal cable positioning, then reassess after securing the wiring.

PDF and software documents

Use Delta PLC accessories PDF and software files for the manufacturer's cable selection guide and related documents. Select the connected device's documentation under Delta PLC and HMI manuals. Check the adapter, cable and terminator model codes separately in the relevant diagram.