Delta IFD9506 Ethernet and Serial Communication Gateway

Delta IFD9506 is a communication gateway between RS-232 / RS-485 and Ethernet, used to connect serial Modbus devices to an Ethernet network. It belongs to Delta DVP interfaces and Delta PLC accessories. When selecting a PLC, drive or panel connection, establish the protocol and communication direction as well as the physical port.

Ethernet, serial ports and power supply

The Ethernet interface provides one RJ45 port, 10/100 Mbps automatic speed detection and Auto MDI/MDIX. Serial connections include RS-232 mini-DIN and RS-485 through RJ11 and terminals. Select from the documented serial rates between 110 and 115,200 bit/s. Treat the RJ11 serial and RJ45 Ethernet connections separately when checking cables and pin assignments.

The specified supply is 24 V DC (-15% / +20%), with 3 W power consumption. The manufacturer specifies isolation in the RS-485 channel, including its power supply. When selecting Delta DVP power supplies, account for every device sharing the supply. Isolation does not guarantee protection against incorrect power or wiring.

Modbus TCP and communication direction

In Serial Master mode, requests from an Ethernet Modbus TCP client are forwarded to serial Modbus devices. In Serial Slave mode, a serial master's request is routed to an Ethernet server using the station-to-IP mapping. Serial Device Server mode uses User Define communication. Select the mode according to which device initiates the request.

For an application involving Delta DVP PLCs, Delta AS PLCs or a Delta DOP-100 HMI, check station address, RTU/ASCII selection, baud rate, parity and stop bits. A family name alone does not establish compatibility; the particular CPU or panel must support the required protocol.

EtherNet/IP version requirements

The manufacturer's manual specifies IFD9506 firmware V2.04 or later, DCISoft V1.21 or later and EIP Builder V1.07 or later for EtherNet/IP Adapter operation. It operates in serial master mode. Implicit messaging reads the monitoring table; explicit messaging supports 0x03 and 0x06. Confirm the installed version before relying on this feature in an older module.

DCISoft, monitoring and cables

Configure IFD9506 using Delta DCISoft over RS-232 or Ethernet. Features include web configuration and monitoring, Smart Monitor, Virtual COM and alarms triggered by three digital inputs. When choosing Delta PLC software, distinguish gateway configuration from PLC project development. The manual states that email alarms do not support account/password authentication or SSL/TLS; select the SMTP server accordingly.

The operation manual lists UC-PRG020-12A among the RS-232 PC connection options. UC-PRG030-20A can be considered for Ethernet cabling. When choosing from Delta DVP programming cables and Delta DVP communication cables, verify the electrical standard and pin assignment as well as the connector shape.

Editor's Note

Before buying a used module, check its firmware information and terminal set alongside the model label. If the project requires EtherNet/IP, confirm the version requirements before purchasing. An Ethernet socket alone is insufficient.

Start with one serial device and a small register read. Establish stable communication before adding other stations. Connecting the complete network immediately makes address and wiring faults harder to isolate.

If the Ethernet link indicator is on but no data arrives, check IP addressing and subnet, operating mode, target station address and serial settings in sequence. Give the module a station address different from the connected serial device.

For RS-485 faults, inspect more than D+ and D-. Check cable routing, signal reference, shielding and termination at both physical ends. Disconnect power before changing terminal wiring and identify common connections from the diagram before measuring.

If communication fails after a power cycle despite successful DCISoft configuration, check the rotary switches and the firmware-dependent setting retention behaviour. Back up IP, serial and monitoring-table settings before restoring factory defaults.

Timeouts under heavy polling do not by themselves establish hardware failure. Ethernet speed does not increase a serial device's response speed. Reduce the polling load and measure response times before adjusting timeouts and request intervals.

PDF manuals and software documentation

Use Delta PLC accessories files for IFD9506 operating instructions, wiring documents and software resources. Controller and panel addressing documents are available through Delta PLC and HMI manuals. For EtherNet/IP applications, confirm that the manual covers the installed firmware.

Related topics

Delta IFD9507 · Delta IFD8500-A · Delta IFD8510-A · Delta IFD8520

Compare interfaces by port count, electrical standard, protocol, isolation and operating mode.

Return to Delta DVP interfaces. Browse controllers in the Delta PLC category and available devices under second-hand Delta products.

External references: Delta IFD9506 manufacturer page · Delta Download Center