Delta IFD8520

Delta IFD8520 Addressable Isolated RS-232 / RS-485 / RS-422 Converter

Delta IFD8520 is an isolated serial interface converter used to connect non-addressable RS-232 equipment to an addressable RS-485 or RS-422 network. Within the Delta DVP interface range, it is considered for incorporating older serial devices into control systems with multiple stations.

When selecting equipment, distinguish RS-232, RS-422 and RS-485 interfaces from the Modbus communication protocol. Matching electrical interfaces alone does not establish compatibility between device commands.

Technical specifications and application scope

The supply range is +9…+35 VDC, with a stated isolation voltage of 3,000 VDC. RS-232 uses a 9-pin female D-SUB connector; network and supply connections use a 10-pin terminal block. The manufacturer's product page specifies a maximum communication speed of 115,200 bps and dimensions of 118 × 71 × 22 mm.

For an application with a Delta DVP PLC or another controller, check the serial port electrical interface, polling command and response format together. The presence of serial ports on both devices is not sufficient to select IFD8520.

Addressed operation and direct transfer

Direct Mode passes received data through. Address Mode forwards messages with a matching address to RS-232, removing the address and delimiter. The resulting command format received by the RS-232 device must therefore be considered.

Delta's technical explanation states that the communication module/gateway function supports ASCII; RTU is excluded from that function. Do not select IFD8520 as a general-purpose Modbus RTU protocol converter. Frame and timing requirements must be verified separately for an application using direct transfer.

For multiple stations, document addresses and the polling sequence. Our Modbus questions and answers and industrial communication sections provide background for assessing the difference between an interface and a protocol.

Connections and configuration checks

The manufacturer's RS-232 drawing identifies pin 2 as RXD, pin 3 as TXD and pin 5 as signal GND. RS-485 uses DATA+/DATA−; RS-422 uses TX+/TX− and RX+/RX−. Match terminal numbers against the markings on the actual unit.

IFD8520 Utility configures serial communication and addressing. Save changes and check that settings survive a power cycle. When selecting connections, distinguish DVP communication cables from DVP programming cables.

Record port settings, the address and operating mode before maintenance. Starting with a short cable and one device before reconnecting the existing network helps separate configuration problems from wiring problems.

Differences from other IFD models

IFD8500-A is considered for isolated RS-232 to RS-422/RS-485 interface conversion, while IFD8510-A serves a repeater function. The need for addressable operation must be assessed separately when selecting IFD8520.

For Ethernet applications, IFD9506 and IFD9507 found in existing installations belong to another group. IFD9502 DeviceNet and IFD9503 CANopen also perform network functions distinct from serial interface conversion.

For computer USB connections, review IFD6500, IFD6503 and IFD6530 according to their specific interfaces. Sharing the IFD name does not make these devices directly interchangeable with IFD8520.

Product status: Delta lists IFD8520 as discontinued in June 2024 and names IFD8500-A as its replacement. If the existing application uses addressed operation, establish how the new solution will provide that function before changing equipment.

Editor's Note

Record the existing configuration first. Before removing a working converter, note the speed, data format, address and mode, and photograph the connections. This makes setting up the replacement considerably easier.

Check what the connected device actually receives. Electrical communication does not prove that the machine is receiving the correct command. Compare the transmitted query with the reply from the RS-232 equipment.

Ask for a transfer test in both directions when buying used. An illuminated indicator is not enough. Check stable operation, retention of settings and repeated responses from a known serial device.

Do not wire terminals from memory. Older PDF copies can show different signal ordering. Compare DATA+/DATA− and TX/RX labels with the markings on the unit, and verify the supply connections separately.

Start with a short test connection. If the module works on the bench but fails on the machine network, inspect cable routing, shielding, termination at the line ends and the reference arrangement. Avoid adding resistors indiscriminately to every device.

Change one setting at a time. Record each result so that useful evidence is preserved. Inspect hardware with power disconnected; investigate loose terminals, broken conductors and connector solder joints before working on board components.

PDF manuals and software

Use our Delta PLC accessories PDF and software files page for related documents. Review operating modes, wiring and Utility instructions in the IFD8520 User's Manual against the version of your module.

Related subjects

For other equipment and system information, see Delta PLC accessories, DVP interfaces, used Delta PLC models and industrial communication.

Navigation: Used Delta products | Delta PLC models | PLC accessories | DVP interfaces | PDF and software files

External references

Delta IFD8520 technical product page | Delta: IFD8520 gateway and ASCII explanation | Delta IFD8520 User's Manual, archive copy | Delta IFD8520 product status