Delta IFD6500

Delta IFD6500 — USB / RS-485 Communication Converter

Delta IFD6500 is a communication converter connecting a computer’s USB port to suitable RS-485 equipment. It belongs to the Delta DVP interfaces range. With suitable cabling and software, it can be considered for service communication with DVP PLCs and other supported industrial equipment. Check the target model’s interface and protocol support separately.

Main specifications — 2021 instruction sheet

Item Value
Power supplyUSB; no external supply required
Power consumption0.4 W
Isolation voltage2500 V DC
Serial data-rate range75–115200 bit/s
CommunicationRS-485 half-duplex; automatic direction switching
ConnectorsMale USB Type-A / RJ45
USB standardUSB 2.0
RS-485 length in the manual100 m maximum

The 100 m value applies to the RS-485 side. Assess data rate, cable, topology and electrical noise together. Selecting DVP communication cables and network connectors requires more than matching connector shapes.

RJ45 pins: account for the documentation difference

Manufacturer document Pin 4 Pin 5
IFD6500 / IFD6530 Instruction Sheet — 2021-10-28SG+SG−
PLC/HMI Cable Selection Guide — 2019-08-15, page 1-82SG−SG+

The two manufacturer documents give different IFD6500 pin assignments. This alone does not establish a hardware revision change. Use the actual unit’s markings, its applicable wiring diagram and the correct connector view; obtain manufacturer confirmation where the assignment is uncertain. The 2021 instruction sheet marks pins 1, 2, 3, 6, 7 and 8 as Reserved.

Difference from IFD6530

IFD6530 is described by Delta for C2000 applications with a +9 V auxiliary supply. Do not assume the same auxiliary supply function for IFD6500. Both products being USB/RS-485 interfaces does not establish that an existing cable is directly interchangeable.

Driver installation and connection settings

The manufacturer requires users to extract the USB driver package before connecting the unit and completing installation. Green indicates power; flashing orange indicates data transmission. Check operating-system compatibility against the driver package used.

For the first connection, verify that the operating system recognizes the device and the application selects the correct communication port. Then match the target address, baud rate, parity, data bits, stop bits and ASCII/RTU mode where applicable. Automatic direction switching does not mean that the converter automatically discovers those target settings.

Supported DVP PLC applications use WPLSoft or ISPSoft; check COMMGR settings according to the software arrangement. When selecting DVP programming cables, distinguish the PLC’s RS-232, RS-485 and USB interfaces. Do not assume one cable suits every DVP model.

Different roles of other IFD models

IFD6503 provides USB/CAN connectivity; IFD8500-A converts between RS-232 and RS-422/485; and IFD8510-A repeats line signals. IFD8520 provides an addressable serial-interface function. Select these products according to their different connection requirements.

IFD9502 serves DeviceNet, IFD9503 serves CANopen, and IFD9506 supports Modbus TCP / EtherNet/IP over Ethernet. IFD6500 provides the interface between a computer and suitable RS-485 equipment; it does not perform those gateways’ protocol functions.

Editor’s Note

Begin with a short, known-good cable. Leave long lines, USB hubs and extra adapters out of the first test. If the computer does not recognize the converter, check the USB port and driver installation before making random changes on the RS-485 side.

This model has a documented pin-assignment discrepancy. Do not build a cable from conductor colours or a single online drawing alone. After confirming the applicable diagram, check continuity on the disconnected cable. Do not apply external voltage to the converter’s data pins.

A flashing orange LED alone does not prove that a request received a valid reply. Read a known register and compare it with the equipment display. If a write test is necessary, choose a safe test parameter and record its original value first.

If one device fails to reply, check its address and serial format. If several devices disconnect, inspect the cable, shielding, line arrangement and common connections. Change one variable at a time and record the result to make fault location easier.

Inspect the RJ45 latch, USB housing and cable entries for movement or damage. If moving the cable breaks communication, investigate the mechanical fault. After any connector or solder repair, repeat an actual communication test.

For used equipment, request a read test with suitable equipment, a model-label photo and the cable details. A power LED alone is insufficient. Back up the existing project and parameters before connecting to an operating PLC or drive; do not begin with a reset or bulk write.

PDF, software and related topics

Use the Delta PLC accessories PDF and software files page for installation documentation and software links. Further documents are available under Delta user manuals and Delta PLC and HMI manuals.

Navigation: IFD6500 main page · Delta PLC accessories · Delta PLC models · Used Delta products

External references

Delta IFD6500 / IFD6530 Instruction Sheet — 2021-10-28 · Delta PLC/HMI Cable Selection Guide — 2019-08-15, 1-82 · Delta IFD Series — Functions and Applications