Delta DOP-100: touchscreen HMI models and software selection

Delta DOP-100 is a touchscreen HMI family for machine screens, PLC data, alarms, recipes and operator commands. Basic, Standard, Advanced, Multimedia and handheld applications have different display, communication and mechanical arrangements. Identical screen size does not establish identical cutouts, serial interfaces or Ethernet capabilities.

This page covers classic DOP-100 models and maintenance of existing projects. DOP-100L and DOP-300 are separate product generations. Select documentation by complete model and hardware revision. Manufacturer documents are collected in the Delta HMI PDF archive; use Delta HMI files for related families.

Model comparison · Serial channels and connectors · DIAScreen / DOPSoft · Panel replacement · PDF documents

Hardware classes

B identifies basic, C standard, E/I standard Ethernet, W advanced narrow-frame and M multimedia models. Later documents also include D, S and P types. A letter alone does not determine every specification; Ethernet and serial-channel counts can vary with screen size within the W group.

Multimedia functions are not common to every DOP-100. Camera, video and VGA functions depend on the applicable M hardware. Check SD cards, audio, memory and remote-access features against the actual model/software table.

Classic DOP-100 model comparison

The following dated comparison uses PDF 26–30 of the 26 March 2019 catalogue. Dimensions are width×height. Serial-channel counts are not physical D-sub connector counts. Check the device drawing, tolerances and hardware revision before fabrication.

DOP-103BQ: Basic; 4.3 inch / 480×272; 0 Ethernet and 2 serial channels. Catalogue cutout: 118.8×92.8 mm.

DOP-107BV: Basic; 7 inch / 800×480; 0 Ethernet and 2 serial channels. Catalogue cutout: 196.9×142.9 mm.

DOP-107CV: Standard; 7 inch / 800×480; 0 Ethernet and 3 serial channels. Catalogue cutout: 196.9×142.9 mm.

DOP-110CS: Standard; 10.1 inch / 1024×600; 0 Ethernet and 3 serial channels. Catalogue cutout: 261.3×189.3 mm.

DOP-107EG: Standard Ethernet; 7 inch / 800×600; 1 Ethernet and 3 serial channels. Catalogue cutout: 172.4×132.4 mm.

DOP-107EV: Standard Ethernet; 7 inch / 800×480; 1 Ethernet and 3 serial channels. Catalogue cutout: 196.9×142.9 mm.

DOP-103WQ: Advanced; 4.3 inch / 480×272; 1 Ethernet and 2 serial channels. Catalogue cutout: 118.8×92.8 mm.

DOP-107WV: Advanced; 7 inch / 800×480; 1 Ethernet and 3 serial channels. Catalogue cutout: 186.8×126.8 mm.

DOP-110WS: Advanced; 10.1 inch / 1024×600; 1 Ethernet and 3 serial channels. Verify the cutout against the actual revision: the installation sheet gives 255×170 mm in its table and 255.5×170.5 mm in its drawing. Check drawing tolerances and the device revision.

DOP-112WX: Advanced; 12 inch / 1024×768; 2 Ethernet and 4 serial channels. Catalogue cutout: 302.7×228.7 mm.

DOP-115WX: Advanced; 15 inch / 1024×768; 2 Ethernet and 4 serial channels. Catalogue cutout: 372.4×283.7 mm.

DOP-112MX: Multimedia; 12 inch / 1024×768; 2 Ethernet and 4 serial channels. Catalogue cutout: 302.7×228.7 mm.

DOP-115MX: Multimedia; 15 inch / 1024×768; 2 Ethernet and 4 serial channels. Catalogue cutout: 372.4×283.7 mm.

7-inch models are not automatically mechanical replacements: DOP-107EG has 800×600 resolution and a 172.4×132.4 mm cutout; DOP-107EV has 800×480 and 196.9×142.9 mm; DOP-107WV has 800×480 and 186.8×126.8 mm. Verify project resolution and layout as well as hardware.

Additional models and suffixes

The 14 December 2023 CE Rev.14 appendix lists 33 model codes. Additional names are DOP-103BQZ0, DOP-103DQ, DOP-103DQZ0, DOP-103SQ, DOP-103SQZ0, DOP-103WQZ0, DOP-105CQ, DOP-107BG, DOP-107DV, DOP-107IV, DOP-107PV, DOP-107SV, DOP-107TV, DOP-107WVCS, DOP-108IG, DOP-110CG, DOP-110DS, DOP-110IG, DOP-110IS and DOP-110WSY0.

A model’s inclusion in a CE appendix does not establish equivalent ports or features. Retain Z0, Y0 and CS suffixes instead of copying every standard-model specification. Use a model datasheet for detailed electrical and mechanical selection. The revision history records Rev.05=2019-06-14 and Rev.06=2019-09-30.

Serial-channel and connector counts

COM1, COM2 and COM3 can be separate software channels carried on different pins of a shared D-sub connector. The DOP-103WQ/107 WV/110 WS pin sheet shows two channels for DOP-103WQ and the COM1 plus COM2/COM3 arrangement for DOP-107WV/110 WS. Three serial channels do not necessarily mean three 9-pin sockets.

Verify port mode, pin numbers, signal direction and the peer device when selecting RS-232, RS-422 or RS-485. HMI programming/connection cables and communication peripherals perform different roles. Distinguish USB Host from USB Slave and select a project-transfer path supported by the actual panel.

For Ethernet, match panel IP/subnet settings, PLC address, selected driver and data map. An Ethernet connector does not establish identical Modbus TCP, EtherNet/IP, VNC or other functions across models. Select the correct driver/register map for DVP, AS and AH PLC applications.

Software: DIAScreen and legacy DOPSoft 4 projects

Delta currently directs DOP-100 users to DIAScreen. Use the official DIAScreen product page and DIAStudio download section; downloads may require sign-in. Check target model, firmware and conversion support against the chosen release.

DOPSoft 4 maintenance ended on 23 October 2023; its final version is 4.00.16.30. The manufacturer advisory recommends moving to DIAScreen. The archived DOPSoft 4 manual is for understanding and maintaining existing projects. The official legacy DOPSoft 4 record remains a separate reference.

Screen Editor, DOPSoft 2, DOPSoft 4, TPEditor and DIAScreen do not share an interchangeable project target. Treat DOP-A, DOP-AE, DOP-AS, DOP-B and DOP-W files according to their own generations. Opening an old file does not prove lossless conversion of every object or communication setting.

The HMI screen project and PLC program are separate. ISPSoft or WPLSoft logic is not a DOP-100 screen project. Use Delta PLC software for the controller side; a shared brand does not make a TPEditor project a DOP-100 project.

DOP-B migration and replacement

The DOP-100 transition manual explains full/partial compatibility, target selection and software differences. Its historical example remaps RS-422 from COM1 to COM2 when converting DOP-B03S210 to DOP-103BQ. A recommended replacement model does not automatically preserve wiring and project behaviour.

Compare cutout/tolerance, enclosure depth, connector clearance, resolution,24 VDC supply, pinout, storage and source project. Check mounting/power connections and HMI power supplies against actual consumption and peripherals. Front-panel IP65 protection depends on correct mounting; it does not protect an exposed rear enclosure.

Back up the editable source project, model/firmware, software release, recipes/critical retained data, communications and separate PLC project. Check upload permissions, passwords and recoverable content before assuming a complete source can be read from the panel. Convert a separate copy of the working file.

PDF manuals and software documents

These documents are prepared for the DOP-100 section of the shared Delta HMI PDF page. Actual editions and languages are identified individually. The 2019/2020 catalogues are historical hardware references, not a new DOP-100L catalogue or a current datasheet for every model.

DOP-100 catalogue — 2019-03-26 — English; 36 pages; 3.48 MB. 36 pages. Display, serial channels, Ethernet and mechanical comparison for classic B/C/E/W/M models; specification tables on PDF 26–30. Historical edition.

DOP-100 catalogue — 2020-01-09 — English; 40 pages; 3.68 MB. 40 pages. Additional D/I/C models, specification tables and drawings. Contains inconsistent DOP-110WS dimensions and some table headings; not a stand-alone fabrication template.

DOP-103WQ / 107 WV / 110 WS installation and pin sheet — includes Turkish — Multilingual; includes Turkish; 8 pages; 1.38 MB. 8 pages; English, Turkish and Chinese. Turkish on PDF 3–4. COM pinouts, 24 VDC, mounting and specifications. DOP-110WS table 255×170 versus drawing 255.5×170.5 mm; the internal discrepancy is preserved.

DOP-100 EU declaration of conformity Rev.14 — English; 3 pages; 0.92 MB. 3 pages. Appendix lists 33 model codes; final page records revision history. Rev.05=2019-06-14; Rev.06=2019-09-30. Does not establish equivalent ports or functionality.

DOP-100 EU declaration Rev.04 — historical — English; 2 pages; 0.49 MB. 2 pages. Historical declaration for early model names. Not Rev.05 or Rev.14 and not a substitute for assessing the actual current device.

DOP-B to DOP-100 transition manual — English; 27 pages; 3.20 MB. 27 pages. Model/project conversion, accounts/passwords, audio/printer and COM changes. PDF 7–8 models/projects; PDF 22–24 RS-422 remapping. Statements about future 2019 models remain historical.

DOPSoft 4 user manual — legacy project maintenance — English; 2093 pages; 62.83 MB. Full 2093-page manual. Supported models on PDF 14; projects, objects, communication, recipes, alarms, macros/Lua and transfers. Historical software reference because DOPSoft 4 maintenance has ended.

DOPSoft 4 end-of-life and DIAScreen advisory — English; 2 pages; 0.63 MB. 2 pages. DOPSoft 4 end-of-life, final version 4.00.16.30 and the manufacturer’s DIAScreen recommendation. Not an installer or firmware package.

Editor’s note

Do not select a replacement solely by its 7-inch screen. 107 EG,107 EV and 107 WV have different cutouts/resolutions. Measure the opening and verify the label, depth and cable clearance.

For DOP-110WS, compare the dimension table and drawing carefully. Resolve the half-millimetre discrepancy against the actual hardware revision before cutting a panel.

Collect working HMI sources, recipes, communications and the separate PLC program while the machine still operates. Record passwords and the software release with the backup.

A fitting connector does not validate an old cable. COM channels may share a D-sub with different pin assignments. Verify both ends and the electrical interface before connecting.

For slow startup, intermittent display or inaccurate touch, check 24 V under load, connectors, moisture/dirt and mechanical pressure. A factory reset or firmware write should not be the first diagnostic step.

Preserve the working project before migration. Verify a known read value first, then test keys, alarms and recipes in sequence. Compilation does not prove correct machine behaviour.

Related topics

Delta HMI Files · Delta DOP-A · Delta DOP-AE · Delta DOP-AS

Delta DOP-B · Delta DOP-H07 · Delta DOP-W · Delta DOP-107H

Delta HMI Modules and Accessories · Delta HMI Mounting and Power Connections · Delta HMI Programming and HMC Cables · Delta HMI Shared Power Supplies

Delta HMI Communication Peripheral Units · Delta DVP PLC series · Delta AS PLC series · Delta AH PLC series

Delta PLC software · Delta WPLSoft · Delta ISPSoft · Delta HMI PDF files

External references