Delta DVP programming cables
Delta DVP Programming Cables
Delta DVP programming cables connect a computer to a suitable PLC programming or communication port. Port arrangements vary across Delta DVP PLC series, so USB, RS-232 and Ethernet connections require separate selection. The UC-PRG group shown here also includes TP/HMI project-transfer cables. Choose by the exact device and port.
When selecting cables under Delta PLC accessories, check the computer connector, PLC/panel port, electrical interface and any converter built into the cable. A USB cable, USB-to-RS-232 converter and Ethernet cable perform different connection functions.
Mini-USB PLC cables
UC-PRG015-01A: A 1.5 m USB-to-mini-USB cable. The manufacturer's selection table lists suitable mini-USB-equipped PLCs such as DVP-SE and DVP-SX2. It connects to the PLC's native USB interface.
UC-PRG030-01A: The 3 m USB-to-mini-USB option. Mini-USB, micro-USB and USB Type-B connectors are different; check the actual device socket.
Programming cable with USB-to-RS-232 conversion
UC-PRG020-12A: Provides a 2 m USB-to-RS-232 programming connection. The manufacturer's drawings show USB at the computer and 8-pin male mini-DIN or female DB9 device-side arrangements. Check the active converter, connector adapter and USB driver together. This model should not be treated as a passive DB9-to-mini-DIN cable.
USB Type-B TP/HMI cables
UC-PRG015-02A: A 1.5 m USB-to-USB Type-B cable for the relevant USB connections on Delta TP04P, Delta TP70P and suitable DOP models listed by the manufacturer. It is not the required cable for every DVP PLC.
UC-PRG030-02A: The 3 m USB Type-B option. Select the panel's supported software and transfer method alongside the cable.
DB9 serial and RJ45 Ethernet cables
UC-PRG030-10A: A 3 m serial cable with female DB9 connectors at both ends. The manufacturer's drawing crosses Tx and Rx; a straight-through DB9 cable with matching connectors is not automatically equivalent. A computer without a physical serial port needs a suitable USB-to-RS-232 interface separately.
UC-PRG030-20A: A 3 m RJ45-to-RJ45 Ethernet cable for compatible Ethernet-equipped devices. Configure the PLC's IP address, computer network settings and software connection separately. This cable does not convert RS-232 or RS-485 signals.
Selecting by DVP series
For families such as DVP-ES, DVP-ES2, DVP-SS2 and DVP-EH3, check the complete CPU code and the electrical standard of the selected COM port. An 8-pin mini-DIN RS-232 connection differs from RS-485 field terminals. Compare serial options under Delta DVP communication cables.
Select Delta WPLSoft or Delta ISPSoft according to device support. For connections using Delta COMMGR, check the communication driver and channel definition. A cable appearing on the computer does not establish that the correct PLC target and programming tool have been selected.
USB drivers and COM ports
The manufacturer's UC-PRG020-12A driver instructions identify Silicon Labs CP210x USB to UART Bridge and its virtual COM port. Match the driver to the cable hardware and operating system. A native PLC USB driver and a USB-to-serial converter driver should not be assumed interchangeable.
If communication fails, check device power, USB detection, the selected COM port, other applications using that port and communication settings. For Ethernet, troubleshoot IP addressing and network access instead of COM-port selection. Do not transfer one interface's settings unchanged to another.
Editor's Note
Start with the full PLC code and the actual port. A cable described only as “for Delta” is insufficient. Mini-USB, USB Type-B, mini-DIN and RJ45 serve different connections. Never force a plug into a socket.
On a working machine, read and back up the program first. Preserve the source project, parameters and communication settings. Do not download an unfamiliar program merely to test the connection.
For a USB-to-serial cable, keep Device Manager open while connecting and disconnecting it to identify the COM port. If no port appears, check the driver, USB socket and cable first. If the port exists but the PLC does not respond, check the device-side connection and communication settings.
A passive serial cable can be checked for continuity with both ends disconnected and power removed. This test alone does not establish that an active converter works. Inspect DB9 and mini-DIN plugs for bent pins, broken conductors and connections that fail when moved.
An Ethernet link light does not establish a working programming connection. Confirm the correct IP address and CPU target. On networks with several PLCs, verify device identity before writing, so that cable troubleshooting does not alter the wrong machine.
Site resources, PDFs and software links
Use Delta PLC accessories files for cable drawings, driver information and related documents. Select CPU and panel documents under Delta PLC and HMI manuals. Treat the cable driver and PLC programming application as separate files with different functions.
Related topics
For other connections, see Delta PLC cables and Delta HMI programming and HMC cables. Complete cable selection against the device model and port drawing.