Delta DVP-EH3

Delta DVP-EH3 PLC series

Delta DVP-EH3 is the third-generation high-performance compact CPU series in the DVP PLC family. It provides 30K program steps, 12,000 words of data registers and a fastest basic instruction execution time of 0.24 µs. This is not the scan time of the complete program. These PLCs serve packaging, labelling and machine automation requiring sequence control, counting and positioning.

Models, I/O counts and power supply

DVP16EH00R3 / DVP16EH00T3: 8 inputs + 8 outputs. DVP20EH00R3 / DVP20EH00T3: 12 inputs + 8 outputs. DVP32EH00R3 / DVP32EH00T3: 16 inputs + 16 outputs.

DVP40EH00R3 / DVP40EH00T3: 24 inputs + 16 outputs. DVP48EH00R3 / DVP48EH00T3: 24 inputs + 24 outputs. DVP64EH00R3 / DVP64EH00T3: 32 inputs + 32 outputs. DVP80EH00R3 / DVP80EH00T3: 40 inputs + 40 outputs.

These standard models use a 100–240 V AC supply. R3 indicates relay outputs; T3 indicates NPN open-collector transistor outputs. Digital inputs are in the 24 V DC class. Match PNP/NPN sensor outputs and the S/S input common when wiring inductive sensors and photoelectric sensors.

DVP32EH00M3 and DVP32EH00MT are special versions with differential high-speed I/O. After the Y0–Y3 differential outputs, the remaining outputs are relays on M3 and transistors on MT. EH3-L versions support left-side expansion; check the actual connections of DVP32EH00R3-L and DVP32EH00T3-L before replacing a standard EH3.

High-speed counting and motion control

Depending on the CPU and counting mode, the series supports up to four hardware counters in the 200 kHz class. When selecting an encoder, check the incremental encoder's A/B phases, resolution and electrical output. A line-driver encoder requires different wiring from a conventional single-ended sensor.

DVP16/20EH00T3 models provide two axes, while DVP40/48/64/80EH00T3 models provide four axes of 200 kHz pulse output. DVP32EH00T3 depends on revision: the manufacturer specifies 200 kHz at Y0/Y2/Y4/Y6 following the December 2013 upgrade. Check the label and applicable manual on older units. Relay R3 outputs cannot generate high-speed pulses.

For servo or stepper motor control, match the drive's pulse/direction inputs, voltage levels and instruction limits. Mechanical resolution matters alongside the servo versus stepper choice. Establish the home position and limit switches before automatic motion, including applications using linear/arc interpolation.

Programming software and cable

DVP-EH3 is programmed with WPLSoft or ISPSoft. Select the correct EH3 CPU when developing the ladder program. For ISPSoft connections, COMMGR manages the communication channel. Keep the software version, CPU firmware information and source project together.

The standard programming connection uses COM1 RS-232 and a DVPACAB2A30 cable. This approximately 3 m cable has a 9-pin female D-sub PC connector and an 8-pin mini-DIN PLC connector. Choose the correct wiring from the Delta PLC programming cables range.

For a USB-equipped PC, use USB → USB-to-RS-232 converter with its driver installed → DVPACAB2A30 → COM1. Select the assigned COM number in the software and match baud rate, data bits, parity and stop bits to the PLC. Standard EH3 hardware has no built-in USB programming port. Observe the differences between RS-232, RS-422 and RS-485; a USB-to-TTL adapter is unsuitable.

Communication and expansion

The standard CPU has COM1 RS-232 and COM2 RS-485. COM3 requires an appropriate DVP-F232/F422/F485 function card. Match station addresses and serial settings on a Modbus RS-485 network; Modbus ASCII and Modbus RTU use different frame formats. An HMI panel also requires the correct driver and register addresses.

Ethernet is optional. A compatible DVP-FEN01 card provides Modbus TCP and program transfer/monitoring over Ethernet. Its manual requires EH3 firmware 1.12 or later; also verify the exact CPU/card combination. Understand the difference between EtherNet/IP and Modbus TCP: an Ethernet connector does not establish support for every Ethernet protocol.

Compatible expansions allow up to 512 I/O points, subject to module compatibility and the power budget. Add a suitable module/card to measure analog signals. For PID control with a PLC, configure channel scaling and sampling time separately; do not wire the standard CPU as though it had built-in analog channels.

Editor's Note

Record the complete model, hardware revision and installed cards first. With a 32-point T3 unit, confirm the actual fast outputs instead of relying solely on the axis count in an older catalogue.

Back up the running program, retained data, recipes and communication settings. Saving a PC project and updating the PLC's Flash backup are separate operations. Check which values should be retained before writing to Flash.

If BAT.LOW is lit, back up before removing power. Follow the manufacturer's battery selection and replacement procedure; automatic recovery may restore older values from Flash.

The CPU's auxiliary 24 V output is limited to 500 mA, including input consumption. Do not parallel an external DIN rail power supply with this output. If the PLC resets when a contactor operates, check supply voltage under load, cable routing and grounding.

An output LED does not prove that the channel works under load. Test relay contacts with a suitable load and transistor/differential outputs with the correct supply and commons. Prevent machine motion safely while checking pulse quality with an oscilloscope.

For a used PLC, test every digital channel, the required high-speed counters, serial ports and installed cards separately. Successful program transfer or a RUN indication alone does not confirm all functions.

PDF manuals

Use our Delta DVP PLC files page for EH3 installation, electrical wiring, programming and EH3-L documentation. Match the hardware manual to the complete model and revision, and consult the individual manuals for installed function cards.