Delta DVP-EC3

Delta DVP-EC3 Series PLC

Delta DVP-EC3 is an economical, block-type PLC family with fixed digital I/O. It is used for sequencing, timing, counting and basic serial communication in small machines. PLC programming uses WPLSoft; ISPSoft requires checking the CPU version and EC3-8K target. The control sequence can be developed using ladder diagrams.

Earlier 4K and upgraded 8K EC3 versions must be distinguished. The family name and similar ordering codes do not establish identical program capacity or instruction support. EC3 should not be selected as an ES2-style system with directly attachable I/O expansion modules.

EC3 models and I/O distribution

10 I/O: DVP10EC00R3 / DVP10EC00T3 provide 6 inputs + 4 outputs; 14 I/O: DVP14EC00R3 / DVP14EC00T3 provide 8 inputs + 6 outputs.

16 I/O: DVP16EC00R3 / DVP16EC00T3 provide 8 inputs + 8 outputs; 20 I/O: DVP20EC00R3 / DVP20EC00T3 provide 12 inputs + 8 outputs.

24 I/O: DVP24EC00R3 / DVP24EC00T3 provide 12 inputs + 12 outputs; 30 I/O: DVP30EC00R3 / DVP30EC00T3 provide 18 inputs + 12 outputs.

32 I/O: DVP32EC00R3 / DVP32EC00T3 provide 16 inputs + 16 outputs; 40 I/O: DVP40EC00R3 / DVP40EC00T3 provide 24 inputs + 16 outputs.

48 I/O: DVP48EC00R3 / DVP48EC00T3 provide 28 inputs + 20 outputs; 60 I/O: DVP60EC00R3 / DVP60EC00T3 provide 36 inputs + 24 outputs.

The DVPxxEC00R3/T3 CPUs listed above require 100–240 V AC. R3 identifies relay outputs; T3 identifies NPN/sinking transistor outputs. Total I/O does not mean equal input/output counts: the 48-point CPU has 28 inputs + 20 outputs, rather than 24+24.

4K / 8K distinction and programming software

WPLSoft is a programming tool for the EC3 family. Earlier catalogues specify 4k steps. The manufacturer’s programming manual identifies firmware V8.60 and later as the 8K-capacity EC3-8K; select the EC3-8K target when using ISPSoft with this version.

Read the actual CPU version before selecting the project target. Selecting EC3-8K in software does not turn an older CPU into an 8K controller. When transferring a project, review instructions, special M/D devices, retained data and communication settings. For ISPSoft serial connections, configure the appropriate COM port in COMMGR; configure WPLSoft communication settings for the port used.

Which programming cable is required?

For a PC with USB: connect the UC-PRG020-12A USB-to-RS-232 cable to the PLC’s 8-pin mini-DIN COM1 socket. Install the cable driver and select the COM number assigned by Windows. EC3 has no native USB programming socket. A USB printer or Mini-B cable does not provide a direct programming connection.

For a PC with physical RS-232: use the appropriate UC-MS020-01A serial cable. A PC without a serial port requires a suitable USB-to-RS-232 converter for this cable. USB-TTL is not electrically equivalent to RS-232. Use Delta PLC programming cables and the manufacturer’s EC3 wiring diagram to verify the pinout.

RS-232 and RS-485: model differences

10-point and 14-point EC3 models have RS-232 COM1 only; they have no RS-485 port. 16/20/24/30/32/40/48/60-point models add RS-485 COM2 alongside RS-232 COM1. Account for the smaller CPUs’ port limitations when planning an HMI or drive network.

For Modbus RTU, select compatible station addresses, baud rate, parity, data format and master/slave roles. Check D+/D−, SG and the network wiring arrangement. EC3 has no built-in Ethernet port. Serial and Ethernet cables are different; an RJ45-shaped connector elsewhere does not establish Ethernet support.

Power supply, sensors and output wiring

Apply AC mains to L/N; digital inputs use 24 V DC signals. Do not mistake the +24V/24G auxiliary output for a DC CPU power input. Wire input common S/S for the PNP/NPN sensor circuit. Check the auxiliary 24 V output’s current budget for the complete model rather than supplying every field load from it.

An inductive sensor, photocell or limit switch can feed digital inputs with suitable electrical wiring. X/Y addresses use octal numbering; X10 follows X7. Correct panel grounding and separation of signal wiring from motor/power cables help maintain reliable counting and communication.

For R3 relay outputs, check contacts and commons. For T3 transistor outputs, check load supply, UP/ZP terminals and polarity. Assess output ratings against load inrush and shared-terminal current limits. Do not use a PLC output to supply a motor directly.

Timing, high-speed counting and pulse outputs

When developing start/stop sequences, distinguish ON-delay and OFF-delay behaviour. Set timer time bases, reset conditions and power-restoration behaviour for the application; the displayed time value alone is insufficient.

For high-speed encoder counting, check the input terminal, single/two-phase counter mode and CPU version together. Catalogue 20 kHz /10 kHz ratings do not apply equally to every input and counter mode. Excessive input filtering can also cause short pulses to be missed.

The catalogue specifies two independent pulse outputs on Y0/Y1, up to 10 kHz, for suitable transistor versions V8.00 and later. For a servo or stepper motor drive, calculate whether this frequency meets the required mechanical speed and match pulse/direction format and input circuitry. This feature does not apply to relay outputs; a fast-switching terminal rating must not be interpreted as the number of independent axes.

Analog measurement and expansion limitations

Standard EC3 digital inputs do not measure 0–10 V or 4–20 mA analog signals. They cannot directly read Pt100 or thermocouple sensors either. On models with a suitable serial port, reading an external measuring device through communication is different from attaching a local analog module.

ES2 and slim DVP expansion modules cannot attach directly to EC3. If additional local I/O or analog channels are required, evaluate a suitable expandable CPU. Moving to another family such as DVP-ES2 requires reviewing the program, terminal arrangement and supply connections.

Editor’s Note

Check the EC3 label and version before deciding whether it is 4K or 8K. A replacement with the same I/O count may have different firmware, instruction support and program capacity.

Do not look for RS-485 on a 10-point or 14-point model. Use COM1 and the correct USB-to-RS-232 programming cable. If connection fails, first check the driver, COM number, cable and mini-DIN socket.

Back up the program, required retained data and communication settings. Test each input with a suitable 24 V DC signal and verify encoder counting at conditions representative of the machine’s operating speed.

An illuminated output indicator does not complete a load test. Test relay contacts under load and transistor outputs with correct polarity and external load supply. Inspect suppression components on inductive loads.

Do not implement the emergency stop solely in a standard PLC program. Preserve the appropriate safety circuit and verify that restoring power cannot cause unexpected movement.

For repair inspection, disconnect power and verify capacitor discharge before examining the supply, connectors and affected I/O circuit. Finish with loaded operation, communication and controlled power-cycle checks.

Manuals and related topics

Start with Delta DVP PLC files. The existing EC3 installation and wiring document is an earlier 2010 English/Chinese edition. Check the appropriate programming manual’s version notes for later hardware functions and EC3-8K.

Navigation: Delta Automation · Delta PLC · Delta DVP PLC series · DVP-EC3 main page · DVP files

External references

Delta DVP series catalogue, 2024 English edition · Delta DVP-PLC Programming Manual, English · Delta PLC/HMI Cable Selection Guide, English