Delta DVP10EC00T3
Delta DVP10EC00T3 | DVP-EC3 PLC with 6 inputs and 4 transistor outputs
The Delta DVP10EC00T3 is a compact PLC CPU in the DVP-EC3 series. It runs on 100–240 V AC and provides 6 digital inputs at 24 V DC and 4 NPN open-collector transistor outputs. It suits small feeders, labeling stations and standalone control cabinets with a limited number of field signals.
Digital inputs, outputs and pulse support
Check the S/S common for inputs X0–X5 against the installed NPN or PNP sensor type. An inductive sensor can detect a reference position, a photoelectric sensor can detect a passing product, and a capacitive sensor can detect suitable materials. For an incremental encoder, check the input assignment, counter mode and filter time together.
For outputs Y0–Y3, the instruction sheet specifies 5–30 V DC and resistive limits of 0.5 A per point and 2 A per common. Follow Delta’s external 24 V DC auxiliary supply diagram for the UP/ZP output circuit. Check current draw and coil suppression for DC valves and interposing relays. For a run command to a variable frequency drive, check the drive’s input type.
Delta’s catalogue lists independent pulse outputs on Y0 and Y1 at up to 10 kHz for suitable transistor versions V8.00 and later. When selecting a servo or stepper motor drive, verify open-collector input compatibility, the required pulse frequency and the instruction’s output assignment. Record the cabinet fuses, grounding and any separate timer relay settings.
4K and 8K program capacity
Delta’s earlier EC3 specifications list 4K steps. The programming manual identifies firmware V8.60 and later as the 8K-step version. Read the CPU firmware and match the project target before transferring a program.
Programming software, cable and serial port
Use WPLSoft to edit, back up and monitor the ladder program. In ISPSoft, select EC3-8K for the 8K CPU and configure the serial connection in COMMGR. Keep the original PLC project before adapting it.
The only built-in serial port is COM1 RS-232. For PC programming, use the UC-PRG020-12A cable with its 8-pin mini-DIN connector at the PLC. Install the USB driver and select the COM number shown in Windows Device Manager. A PC with a physical RS-232 port can also use the UC-MS020-01A. For an HMI or SCADA connection, match the interface, protocol and serial settings.
Related Delta models
The DVP10EC00R3 has 6 inputs and 4 relay outputs. The DVP14EC00T3 has 8 inputs and 6 transistor outputs. For applications that need built-in RS-485, the DVP16EC00T3 has 8 inputs and 8 transistor outputs, and the DVP20EC00T3 has 12 inputs and 8 transistor outputs. Check the serial port and required field points when selecting the CPU.
Editor’s Note
When buying used, read DVP10EC00T3 on the side label and ask for a photo of the UP, ZP, Y0 and Y1 terminals.
Back up the program and serial settings from the working CPU. Record the firmware version with the backup.
Once power is isolated, photograph the wire numbers at S/S, UP and ZP. Use those photos to check the wiring after replacement.
With machine loads disconnected, check Y0 and Y1 with a suitable test setup. When troubleshooting the PLC, measure the output signal as well as checking the LED.
Before returning the machine to production, verify the safety relay and emergency-stop circuit against the cabinet drawings.