Delta DVP32EC00T3 – EC3 PLC with 16 Inputs and 16 NPN Outputs
The Delta DVP32EC00T3 is a Delta DVP-EC3 PLC powered by 100–240 V AC. It has 16 digital inputs rated at 24 V DC and 16 NPN transistor outputs. It suits machine automation applications such as conveyor sequencing, part counting and basic feeder control.
Inputs, outputs and addressing
Inputs are addressed X0–X17 and outputs Y0–Y17. Addresses use octal numbering, so X10 follows X7. When wiring an inductive sensor, photoelectric sensor or limit switch, check the S/S input common and the PNP or NPN sensor type.
The T3’s NPN outputs sink load current to 0 V. Check the field supply voltage, load current and UP/ZP terminals against the model drawing. The AC supply connects to L/N. Verify the panel’s fuse protection and protective grounding.
High-speed counting and Y0/Y1 pulse outputs
Delta specifies independent pulse output up to 10 kHz on Y0 and Y1 for supported T3 units at V8.00 or later. For position control, check the pulse frequency, command format and electrical input level required by the servo or stepper motor drive.
For high-speed counting with an incremental encoder, check the frequency limits for the selected input and A/B counting mode. With a differential line-driver encoder, use the input diagram to determine whether an interface is required. If the count drifts when a motor starts, review the cable routing and possible sources of electromagnetic interference.
WPLSoft, ISPSoft and programming cables
Use WPLSoft for PLC programming. Earlier EC3 units have 4K program capacity. Delta’s programming manual identifies V8.60 and later as 8K. On these CPUs, select EC3-8K as the ISPSoft project target. Configure ISPSoft serial communication in COMMGR and back up the existing ladder program before replacing the CPU.
For COM1 (RS-232, 8-pin mini-DIN), use a UC-PRG020-12A with a USB-equipped PC or a UC-MS030-01A with a PC that has a physical RS-232 port. Install the USB cable driver and select the COM port shown in Windows. See Delta PLC cables for other options.
COM2 (RS-485) supports industrial communication. On an existing RS-485 Modbus link, record the station address, baud rate and parity. For a Modbus RTU connection to SCADA, read a known address after replacing the CPU to verify the link.
Editor’s Note
Check the label and version. When buying used, ask for the full DVP32EC00T3 code. Confirm the firmware and 4K/8K capacity before transferring a program.
Save the working project. With the machine in a safe state, back up the program, retained data and serial port settings.
Test the output with a load. Check that the output switches a suitable test load while its Y LED is on. Verify the supply to the corresponding UP/ZP group first.
Test Y0 and Y1 separately. On a machine that uses pulse control, measure both lines. Compare the measured signal with the drive’s configured pulse format and required frequency.
Count the required I/O first. Plan for 16 inputs and 16 outputs on this CPU. Check that the field terminals on a replacement agree with the X/Y list.
Related Delta models
The DVP32EC00R3 is the relay version with the same 16 inputs and 16 outputs. Among the transistor models, the DVP24EC00T3 has 12 inputs and 12 outputs, the DVP30EC00T3 has 18 inputs and 12 outputs, and the DVP40EC00T3 has 24 inputs and 16 outputs. Compare field terminals, output type and program target before replacing the CPU.
Internal references and PDF files
Delta DVP PLC PDF files · Delta DVP-EC3 installation and wiring sheet (PDF) · Delta DVP PLC series · Used Delta products
External references
Delta DVP-EC3 electrical specifications and terminal layout (PDF) · Delta DVP PLC programming manual, EC3-8K section (PDF) · Delta PLC/HMI cable selection guide, section 1.3 (PDF)