Delta DVP32EC00R3
Delta DVP32EC00R3 | DVP-EC3 PLC with 16 inputs and 16 relay outputs
The Delta DVP32EC00R3 is a PLC CPU in the DVP-EC3 series. It runs on 100–240 V AC and provides 16 digital inputs at 24 V DC and 16 relay outputs. It can read sensors and sequence contactors, valves and indicators in small conveyors, packaging stations and pump panels.
Inputs and relay outputs
Inputs X0–X17 use octal addressing. X10 follows X7. Check the S/S common against the wiring diagram for the installed NPN or PNP sensors. An inductive sensor can detect part position, a photoelectric sensor can detect a passing product, and a capacitive sensor can detect the presence of suitable materials. For an incremental encoder, check the input’s electrical limits, selected counter mode and input filter together.
The Y0–Y17 relay outputs have four commons. C0 serves Y0–Y3, C1 serves Y4–Y7, C2 serves Y10–Y13, and C3 serves Y14–Y17. Delta’s instruction sheet specifies 2 A per point and 5 A per common for resistive loads. The sheet specifies contact voltages below 240 V AC or up to 30 V DC. For valves and interposing relay coils, check inductive loading and coil suppression. Follow the drive’s digital input diagram when sending a run command to a variable frequency drive.
When replacing the cabinet equipment, record the output-group fuses, protective grounding and any separate timer relay settings.
4K and 8K program capacity
Delta’s earlier EC3 specifications list 4K steps. The programming manual identifies firmware V8.60 and later as the 8K-step version. Read the CPU firmware and match the project target before downloading a program.
Programming software and cable
Use WPLSoft to edit, back up and monitor the ladder program. In ISPSoft, select EC3-8K for the 8K version and configure the serial connection in COMMGR. Keep the original PLC project and field parameters before adapting it.
For programming, connect the UC-PRG020-12A cable to COM1 RS-232. The cable uses USB at the PC and an 8-pin mini-DIN connector at the PLC. Install the Windows cable driver and select the COM number shown in Device Manager. Delta also lists the UC-MS020-01A for a PC with a physical RS-232 port.
If an HMI, drive or SCADA system uses Modbus over COM2 RS-485, record the station address, baud rate, parity and ASCII or RTU mode from the existing system.
Related Delta models
The DVP32EC00T3 has the same 16 inputs and 16 outputs, with transistor outputs. The DVP24EC00R3 has 12 inputs and 12 relay outputs, the DVP30EC00R3 has 18 inputs and 12 relay outputs, and the DVP40EC00R3 has 24 inputs and 16 relay outputs. Select the CPU based on the project’s separate input and output requirements.
Editor’s Note
When buying used, check that the side label reads DVP32EC00R3 and inspect the output terminals.
Back up the program and serial settings from the working CPU first. Record the firmware version with the backup.
Once power is isolated, photograph the wire numbers at C0–C3. Mark the load supply for each relay group.
With machine loads disconnected, test each relay group with a suitable test load. When troubleshooting the PLC, check the contact response under load as well as the Y LED.
Before returning the machine to production, verify the safety relay and emergency-stop circuit against the cabinet drawings.
Related topics and internal references
Industrial communications · Delta DVP PLC files · DVP-EC3 hardware and terminal guide (PDF)
Delta DVP-EC3 · Delta DVP PLC series · Delta main page
External references
Delta DVP-EC3 specifications · Delta DVP-PLC Application Manual (EC3-8K, Delta download page) · Delta PLC/HMI Cable Selection Guide (section 1.3, Delta download page)