Delta DVP30EC00R3

Delta DVP30EC00R3 — 18-input, 12-relay-output PLC

The Delta DVP30EC00R3 is a 30-point PLC CPU from the Delta DVP-EC3 series. It runs from a 100–240 V AC supply and provides 18 digital 24 V DC inputs and 12 relay outputs. Typical applications include packaging, part sorting and conveyor sequencing.

Input addresses and relay commons

The built-in PLC I/O uses octal addresses X0–X21 and Y0–Y13. X20 and X21 are on the right-side terminal block next to the RS-485 terminals. When wiring an inductive sensor, photoelectric sensor or limit switch, check the wiring diagram for the S/S input common arrangement and match it to the PNP or NPN signal.

The relay outputs are split into three groups. C0 serves Y0–Y3, C1 serves Y4–Y7, and C2 serves Y10–Y13. Delta specifies 2 A per point and 5 A per common for resistive loads. For a contactor or valve coil, check the inductive load rating and suppression separately. For a drive that needs a high-speed pulse command, check the supported output channel and firmware on the transistor model.

Programming the 4K and 8K versions

Use WPLSoft to read and back up an existing EC3 Ladder project. Delta’s series product page lists 4K capacity, while the programming manual specifies 8K for firmware V8.60 and later. For that 8K version, select EC3-8K in ISPSoft and configure the serial channel in COMMGR. Read the CPU version and save a backup before making any program changes.

The PC connects through COM1 RS-232. Delta’s cable guide lists the UC-PRG020-12A (2 m) for a USB-equipped PC and the UC-MS030-01A (3 m) for a PC with a serial port. With the USB cable, select the COM number assigned by its driver.

COM2 and field communications

COM2 is the RS-485 port, with D+, D− and SG terminals. The differences between RS-232 and RS-485 affect cable selection for the PC and for field communications. When connecting a Delta DOP-100 HMI or a variable frequency drive over Modbus on RS-485, match the RTU or ASCII mode, station address, baud rate and parity. Keep any SCADA register map with the project backup.

Related Delta models

The DVP30EC00T3 has the same 18-input, 12-output count with transistor outputs. The DVP24EC00R3 has 12 inputs and 12 relay outputs, and the DVP32EC00R3 has 16 inputs and 16 relay outputs. Before moving to the 32-point model, check whether the existing machine uses X20 and X21.

Editor’s Note

Ask for a clear label photo when buying used. Check for the full DVP30EC00R3 code and the R3 suffix. Ask for a photo of the right-side terminal block too.

Read the firmware and program first. A replacement with the same ordering code may have a different program capacity. Back up the recipes and any retained register values the machine needs.

Test X20 and X21 at the bench. Confirm that each address changes in the WPLSoft monitor when you apply its test signal.

Test all three relay groups under load. With machine loads disconnected, use a suitable low-voltage test load to check switching through C0, C1 and C2.

Inspect the terminals before power-up. Check for looseness and discolouration and verify protective grounding. Test program access on COM1 and field communications on COM2 separately.

Internal references and PDF files

Delta DVP PLC PDF files · Hardware, programming and cable guides.

DVP-EC3 series · Delta PLC models · Used Delta equipment

External references

Delta DVP-EC3 instruction sheet · Exact model wiring on PDF page 8 and relay load ratings on page 4.

Delta DVP-PLC programming manual · V8.60 and the EC3-8K target on PDF page 5.

Delta PLC/HMI cable selection guide · COM1 and COM2 connections for DVP30EC00R3 on PDF page 16.