Delta DVP24EC00T3
Delta DVP24EC00T3 – EC3 PLC with 12 inputs and 12 transistor outputs
The Delta DVP24EC00T3 is a compact Delta DVP-EC3 PLC main unit with a 100–240 V AC supply, 12 digital inputs and 12 transistor outputs. It reads sensors, counts parts and switches loads in small conveyors, packaging machines and assembly stations.
Inputs, outputs and terminal groups
The built-in digital inputs use X0–X7 and X10–X13. The outputs use Y0–Y7 and Y10–Y13. Check the 24 V DC field circuit and S/S common when wiring inductive sensors or limit switches. Match the S/S connection to the PNP or NPN field circuit.
The transistor outputs use a 24 V DC auxiliary supply. UP0/ZP0 serves Y0–Y7 and UP1/ZP1 serves Y10–Y13. The sheet identifies ZP as the NPN common and UP as the PNP common. Delta’s instruction sheet specifies 0.5 A per point and 2 A per common group for resistive loads. Check inrush current and protect the output supply with suitable fusing.
High-speed counting and Y0/Y1 pulse outputs
The hardware table lists 20 kHz for X0/X1 and 10 kHz for the other built-in X terminals. For high-speed counting with an incremental encoder, check the input address, single-phase or A/B counting mode and frequency limit together. Delta’s catalogue specifies two independent pulse outputs up to 10 kHz on Y0 and Y1 for applicable hardware version V8.00 and later. Verify the input circuit and required pulse rate on the servo drive or stepper motor drive.
Programming software and 4K/8K versions
Use WPLSoft to edit, upload and monitor a ladder program. Earlier EC3 units are in the 4K class. Delta’s programming manual specifies the EC3-8K target for firmware V8.60 and later. Read the CPU version before programming the PLC. For an 8K unit in ISPSoft, select the EC3-8K target and configure the serial connection in COMMGR. Save a copy of the original project before conversion.
The programming port is COM1 RS-232, 8-pin mini-DIN. Delta lists UC-PRG020-12A for a USB-equipped PC and UC-MS020-01A for a PC with a physical serial port. Connect the appropriate Delta PLC cable. When using USB, install the cable driver and select the COM port assigned by Windows.
COM2 RS-485 is the built-in port for field communications. On a Modbus RS-485 link, match the station address, serial settings and ASCII or RTU mode with the connected device.
Expansion and related Delta models
EC3 has fixed local I/O. For more local points or analog signals, consider an expandable CPU such as the DVP-ES2 with suitable modules. In the EC3 family, the DVP24EC00R3 has 12 inputs and 12 relay outputs, and the DVP20EC00T3 has 12 inputs and 8 transistor outputs. The DVP30EC00T3 has 18 inputs and 12 transistor outputs, while the DVP32EC00T3 has 16 inputs and 16 transistor outputs.
Editor’s Note
Ask for the full code and version. When buying used, ask for pictures of the label and output terminals. If the project targets 8K, connect to the CPU and read its version.
Test the two output groups separately. If Y0–Y7 work and Y10–Y13 stay off, check the UP1/ZP1 supply and connection.
Measure the pulses. If the machine uses Y0/Y1 for pulse control, check both frequency and waveform on a suitable test circuit.
Back up the program and data. Save the project, required retained values and COM2 settings before replacement.
If inputs change when the motor starts, check grounding, the field supply and cable routing. Measure at the PLC terminal when checking for electromagnetic interference.
Internal references and PDFs
Delta DVP PLC files · DVP-EC3 installation and wiring sheet, 2010 (English/Chinese). It includes the DVP24EC00T3 terminal drawing.
Related topics · Delta DVP PLC series · Delta PLC · Used Delta equipment
External references
Delta DVP-PLC programming manual and EC3-8K version note · Delta DVP product catalogue · Delta PLC/HMI cable selection guide, EC3