Delta DVP16EC00T3

Delta DVP16EC00T3 – DVP-EC3 PLC with 8 Inputs and 8 NPN Outputs

The Delta DVP16EC00T3 is a compact PLC main unit from the DVP-EC3 series. It operates from 100–240 V AC, 50/60 Hz. The CPU has 8 digital inputs rated at 24 V DC and 8 NPN transistor outputs. Typical machine automation applications include part feeding, product counting and small conveyors.

Digital inputs and power terminals

The built-in inputs are X0–X7 and the outputs are Y0–Y7. An inductive sensor can detect a metal part, a photoelectric sensor can detect a passing product and a limit switch can indicate end of travel. Check the sensor’s NPN or PNP output and its normally open or normally closed behaviour. Wire the S/S input common according to Delta’s sink/source diagram.

The CPU’s AC supply connects to L and N. +24V and 24G are the auxiliary DC supply output terminals. When tracing PLC I/O, compare the terminal indicator with the corresponding X or Y address in the program.

UP/ZP wiring and transistor outputs

UP is the positive supply terminal for the transistor output circuit. ZP is the NPN output common. Delta specifies an external 24 V DC supply for UP/ZP. Both installation sheets list 0.5 A per point for a resistive load. The common-terminal limit is 2 A/COM in the 2010 sheet and 4 A/ZP in the 2014 sheet. Use the sheet for the unit’s hardware revision when calculating the total load.

When switching an interposing relay or solenoid coil, check inrush and surge suppression. Follow the machine diagram for output circuit fuse protection and cabinet grounding.

Y0/Y1 pulse outputs and encoder counting

Delta’s catalogue lists independent pulse outputs up to 10 kHz on Y0 and Y1 for hardware version V8.00 or later. When connecting a servo drive, match the NPN signal level, pulse/direction format and drive input circuit. For an encoder, check the input terminal and high-speed counter mode separately. Single-phase and A/B frequency limits depend on the selected counting mode.

Programming software and cable

Use WPLSoft to read, back up or monitor the ladder program. The early catalogue lists a 4K-step capacity. Delta documents 8K steps for firmware V8.60 or later. With that firmware, select EC3-8K in ISPSoft and configure the serial connection in COMMGR.

Use COM1 RS-232 for programming. The UC-PRG020-12A serial programming cable is 2 m long, with a female DB9 connector at the PC and a male 8-pin mini-DIN connector at the PLC. If the computer has no serial communication port, add a separate USB-to-RS-232 adapter with its driver installed and select the COM port assigned by Windows.

COM2 RS-485 can connect an HMI or field device over Modbus/RS-485. Compare the station address, baud rate, parity and ASCII/RTU format with the existing program.

Expansion and related Delta models

The EC3 has a fixed onboard I/O count. The DVP16EC00T3 does not support local side-mounted expansion modules. The DVP16EC00R3 offers the same 8 inputs and 8 outputs with relays. For more points, the DVP20EC00T3 has 12 inputs and 8 outputs, and the DVP24EC00T3 has 12 inputs and 12 outputs. The smaller DVP14EC00T3 uses COM1 RS-232 for its serial connection. For local expansion, see the DVP16ES200T and compatible ES2 modules.

Editor’s Note

For a used unit, ask for clear photos of the DVP16EC00T3 label and the UP/ZP terminals. If you can connect to the CPU, read its version in the software.

Read the program through COM1 first. Save the machine’s retained values and COM2 settings with the backup.

If several Y indicators light and their loads all stay off, start with the external 24 V DC supply and the ZP return. A common connection fault can affect several channels.

If only one channel fails, disconnect the machine load and test the output with a suitable DC bench load. Check the coil and its suppression component too.

Check the pulses on Y0 and Y1 individually on the bench. If pulses are present and the drive stays still, check the drive input type and common connection first.

When replacing a relay-output model, review the load voltages and common terminals in the cabinet diagram. The T3 requires the correct UP/ZP wiring and compatible DC loads.

OtomasyonAVM PDF files and internal references

Delta DVP PLC PDF Files · Early DVP-EC3 installation sheet (2010, English and Chinese PDF)

Delta DVP PLC series · Delta PLC overview · Used Delta equipment

External references

DVP-EC3 installation sheet – DVP16EC00T3 terminal layout (2014) · Delta DVP catalogue – EC3 model table and pulse support · Delta DVP-PLC Application Manual – Programming · Delta PLC/HMI Cable Selection Guide – EC3 section