Delta DVP24EC00R3
Delta DVP24EC00R3 – 24-point relay-output PLC
The Delta DVP24EC00R3 is a Delta EC3 series PLC with a 100–240 V AC supply, 12 digital inputs and 12 relay outputs. It reads sensors, runs machine sequences and switches on/off loads such as contactors and valves in packaging equipment, conveyors and small control panels.
Inputs, relay outputs and common terminals
The 24 V DC inputs X0–X13 use octal addressing. Wire PNP and NPN sensors to suit the input group’s S/S common and the sink/source wiring diagram. An inductive sensor can detect a metal part, a photoelectric sensor can detect a product on a conveyor and a limit switch can confirm the end of travel. Check NO and NC contact selection against the program’s input logic.
The relay outputs are Y0–Y13. Common C0 serves Y0–Y3, C1 serves Y4–Y7 and C2 serves Y10–Y13. The resistive-load rating is 2 A per point and 5 A total per common. For coils, check inrush current, the relay contact load rating and suitable protection. Check fuse sizing and the panel’s grounding against the wiring diagram.
The built-in inputs sense switching states. 0–10 V or 4–20 mA measurement requires suitable external measurement hardware and a data interface. See digital and analog inputs and analog signal types when choosing sensors.
Programming software, cable and communications
Use WPLSoft for standard 4K EC3 projects. Delta’s programming manual lists 8K program capacity and the EC3-8K target in ISPSoft for updated DVP24EC00R3 units running firmware V8.60 or later. Set up ISPSoft communications through COMMGR. The PLC programming and ladder diagram guides cover the basics.
Use COM1, an 8-pin mini-DIN RS-232 port, to transfer or back up the program from a PC. Use the Delta UC-PRG020-12A with a USB PC or the Delta UC-MS020-01A with a PC that has an RS-232 port. See the Delta programming cable guide for cable selection.
For field devices, check the D+, D− and SG terminals on COM2 RS-485. For Modbus over RS-485, match the serial settings and check the device address. The guides to Modbus RTU, RS-232, RS-422 and RS-485 and industrial communications are useful when connecting a drive or operator panel.
Editor’s Note
Read the label. If you are buying used, ask for a photo showing the full DVP24EC00R3 code. The transistor-output T3 version looks similar.
Back up first. If replacing a machine’s PLC, read the firmware version and back up the program if you have access. Check the replacement unit’s capacity against the project size.
Start with the common. If four outputs stop working together, start by checking the feed to their C0, C1 or C2 common.
Test the contact under load. Disconnect the machine loads and use a suitable test load. A click alone tells you little about the condition of the contacts. Measurement and testing guide
Check both ports. Confirm the PC can reach the PLC through COM1 and that the field device can exchange data through COM2.
Related Delta models and topics
DVP24EC00T3 · 12 inputs and 12 NPN transistor outputs | DVP30EC00R3 · 18 inputs and 12 relay outputs | DVP32EC00R3 · 16 inputs and 16 relay outputs
Delta DVP PLC series · Delta EC3 used models