Delta DVP14EC00R3
Delta DVP14EC00R3 – EC3 PLC with 8 Inputs and 6 Relay Outputs
The Delta DVP14EC00R3 is a Delta DVP-EC3 PLC powered by 100–240 V AC. It has 8 digital inputs rated at 24 V DC, 6 relay outputs and COM1 (RS-232). It suits machine automation applications such as small conveyors, part detection and station sequencing.
Inputs, relay groups and power supply
Inputs are addressed X0–X7 and outputs Y0–Y5. When wiring an inductive sensor, photoelectric sensor or limit switch, check the S/S input common and the PNP or NPN sensor type. For continuous measurements, account for the difference between analog and digital inputs.
C0 is the common for Y0–Y3, and C1 is the common for Y4–Y5. For resistive loads, Delta specifies relay contact limits of 2 A per output and 5 A per common. Allow for inrush current and use suitable transient suppression when switching a contactor or valve coil. Check the panel schematic for fuse protection and protective grounding. Verify the emergency-stop function in the machine’s safety circuit.
High-speed counting
The Delta installation sheet specifies up to 20 kHz input bandwidth on X0–X3 for EC3 units at V8.00 or later. With an incremental encoder, check the frequency limit of the selected counter and A/B counting mode. For a differential line-driver encoder, use the input drawing to determine the appropriate interface. If counts become erratic when a motor starts, check cable routing and possible sources of electromagnetic interference.
WPLSoft, ISPSoft and COM1 connection
Use WPLSoft for PLC programming. Earlier EC3 units have 4K program capacity. Delta identifies CPUs at V8.60 or later as 8K and specifies the EC3-8K target in ISPSoft. Configure the ISPSoft serial connection in COMMGR. Back up the existing ladder program before replacing the CPU.
For COM1 (RS-232, 8-pin mini-DIN), use UC-PRG020-12A with a USB-equipped PC or UC-MS030-01A with a PC that has a physical RS-232 port. Install the USB cable driver and select the COM port assigned by Windows. See Delta PLC cables for details.
This 14-point model provides its built-in serial connection through COM1. For industrial communication, match the baud rate, parity and station address on the connected HMI or SCADA device. Verify the Modbus ASCII or Modbus RTU setting at both ends.
Editor’s Note
Check the label first. When buying used, ask for the complete DVP14EC00R3 code and a close-up of the terminals. Check the CPU version online to identify program capacity.
Back up the program and port settings. With the machine in a safe state, save the project, required retained data and COM1 settings.
Test both relay groups separately. Use a suitable test load on the outputs you need from the C0 and C1 groups. Check the Y LED alongside the load response.
Check S/S against the diagram. If several inputs fail to respond together, check the input common and field supply first.
Test the operator panel link. After service, confirm that the HMI on COM1 can read a known value.
Related Delta models
The DVP14EC00T3 has the same 8 inputs and 6 outputs with NPN transistor outputs. The relay-output DVP10EC00R3 has 6 inputs and 4 outputs, the DVP16EC00R3 has 8 inputs and 8 outputs, and the DVP20EC00R3 has 12 inputs and 8 outputs. The DVP16EC00R3 and DVP20EC00R3 also provide COM2 (RS-485).
Internal references and PDF files
Delta DVP PLC PDF files · Delta DVP-EC3 installation and wiring sheet (PDF) · Delta DVP PLC series · Used Delta products
External references
Delta DVP-EC3 electrical specifications and 14EC terminal diagram (PDF) · Delta DVP PLC programming manual, EC3-8K section (PDF) · Delta PLC/HMI cable selection guide, section 1.3 (PDF)