Delta DVP60EC00T3

Delta DVP60EC00T3 – EC3 PLC with 36 inputs and 24 NPN outputs

The Delta DVP60EC00T3 is a Delta DVP-EC3 PLC CPU with a 100–240 V AC supply, 36 digital inputs at 24 V DC (X0–X43) and 24 NPN transistor outputs (Y0–Y27). X and Y addresses use octal numbering. The controller suits sequence control on conveyors, packaging equipment and assembly machines with multiple field signals.

Inputs, output supply and pulse limits

Check the AC supply and 24 V DC field inputs separately. Match the S/S common to the PNP or NPN sensor circuit and follow Delta’s diagram for the required sink/source arrangement. An inductive sensor can detect metal, a photoelectric sensor can detect passing products and a limit switch can report end-of-travel. Match the NO/NC contact action to the condition in the program.

The output groups require an external 24 V DC auxiliary supply at UP/ZP. Delta’s sheets list 0.5 A per point for resistive loads. Check the group current limit in the hardware sheet for the unit. Account for coil inrush, suppression and fusing. Use a suitable interposing relay where needed and check panel grounding.

The earlier EC3 sheet specifies 1 kHz for transistor outputs. The 2014 edition lists 10 kHz for the designated outputs. For a stepper motor drive, verify the pulse channel, frequency and drive input compatibility against the CPU hardware revision. Check input frequency and counter mode separately for encoder feedback.

4K/8K, programming software and cable

Use Delta WPLSoft to read and back up the ladder diagram project. Earlier EC3 documentation lists 4K steps. Delta’s application manual specifies 8K steps for firmware V8.60 or later. When programming the PLC with ISPSoft on this version, select EC3-8K and configure the serial connection in COMMGR.

Connect a USB-equipped PC to the COM1 RS-232 mini-DIN port with the UC-PRG020-12A converter cable. Install the driver and select the COM number assigned by Windows. A PC with a physical serial port can use the UC-MS020-01A. See Delta PLC programming cables for connection options.

RS-485 and related Delta models

COM2 is the RS-485 field port. On a Modbus RS-485 link, match the station address, baud rate and serial framing. Check whether the existing project uses Modbus RTU or ASCII. See the RS-232, RS-422 and RS-485 comparison and industrial communication guide for interface selection.

The DVP60EC00R3 has the same 36 inputs and 24 outputs, with relays. The DVP48EC00T3 has 28 inputs and 20 transistor outputs. The DVP32EC00T3 has 16 inputs and 16 transistor outputs. Compare the I/O addresses, UP/ZP groups and project target before replacing the CPU.

Editor’s Note

Ask for the full nameplate when buying used. Check the DVP60EC00T3 code, the terminals and the firmware version reported by the software.

Back up the program before removing the CPU. Save the retained data and COM2 settings as well. Check the replacement CPU’s project capacity before downloading.

Check the output under load. With machine loads disconnected, use a suitable DC test load to check the output, UP/ZP supply and common connection. See the electrical measurement and test guide.

Measure the waveform in pulse applications. Safely prevent machine movement and verify the waveform and operating frequency at the drive input.

Test both serial ports separately. Read the program through COM1 and verify data exchange with a field device through COM2.

Internal references and PDF files

Delta DVP PLC PDF files · OtomasyonAVM EC3 wiring sheet (earlier edition) · Delta DVP-EC3 · Delta DVP PLC series

External references

Delta DVP-EC3 instruction sheet (2014) · Delta DVP catalogue (2024) · Delta DVP Application Manual and EC3-8K version note · Delta PLC/HMI Cable Selection Guide (§1.3)