Delta DVP48EC00R3
Delta DVP48EC00R3 – DVP-EC3 PLC with 28 Inputs and 20 Relay Outputs
The Delta DVP48EC00R3 is a PLC main unit from the DVP-EC3 series. It operates from 100–240 V AC, 50/60 Hz. Its CPU has 28 digital inputs rated at 24 V DC and 20 relay outputs. In machine automation applications such as conveyors, sorting and packaging, it reads sensors, runs the sequence and switches field loads. The I/O terminal blocks are removable.
Digital inputs and addressing
The built-in inputs are addressed X0–X33 and the outputs Y0–Y23. Addresses use octal numbering, so X10 follows X7 and Y20 follows Y17. A photoelectric sensor can detect a passing product, an inductive sensor can detect a metal part and a limit switch can indicate end of travel.
Check whether the sensor has an NPN or PNP output and whether it is normally open or normally closed. Wire the S/S common according to Delta’s sink/source diagram. Connect the CPU’s AC supply to L and N. +24V and 24G are the auxiliary DC supply output terminals. When tracing PLC I/O, compare the terminal indicator with the address in the software.
For an encoder, match the signal level, input terminal and high-speed counter mode. During maintenance, check the count at low speed first and then verify it at the machine’s operating speed.
Relay outputs and common terminals
The 20 mechanical relay outputs are arranged in groups of four on commons C0–C4. For example, C4 is the common for Y20–Y23. The 2014 installation sheet lists resistive load limits of 2 A per point and 5 A per common, with voltage limits of 240 V AC / 30 V DC. For coils, check inrush, contact life and suitable surge suppression.
Check output circuit fuse protection and cabinet grounding against the machine schematic. If a drive requires a high-speed pulse command, check the terminal and firmware support of the appropriate transistor-output version.
Programming software and cable
Use WPLSoft to read, back up or monitor an existing ladder program. Early EC3 catalogues list a 4K-step capacity. Delta documents an 8K-step capacity for firmware V8.60 or later. For a CPU running that firmware, select EC3-8K in ISPSoft. Configure the ISPSoft serial connection in COMMGR.
Use COM1 RS-232 for programming. The UC-PRG020-12A serial programming cable is 2 m long, with a female DB9 connector at the PC and a male 8-pin mini-DIN connector at the PLC. If the PC has no serial communication port, use a separate USB-to-RS-232 adapter with its driver installed and select the COM port assigned by Windows.
COM2 RS-485 is available for Modbus/RS-485 communication with an HMI or other field device. Compare the station address, baud rate, parity and ASCII/RTU settings with the existing program. Back up the PLC program and required retained data before online troubleshooting.
Expansion and related Delta models
The DVP48EC00R3 has a fixed onboard I/O count. Local I/O expansion modules are unsupported. For more points in the same series, the DVP60EC00R3 offers 36 inputs and 24 relay outputs. The DVP40EC00R3 has 24 inputs and 16 relay outputs, and the DVP32EC00R3 has 16 inputs and 16 relay outputs. The DVP48EC00T3 provides the same 28/20 split with transistor outputs. For local expansion, see the CPU and module options in the DVP-ES2 range.
Editor’s Note
For a used unit, ask for photos of the DVP48EC00R3 nameplate and both removable terminal blocks. Check the latches and look for discoloured terminals.
Read the current program through COM1 before writing to the CPU. Keep the firmware version and retained machine values with the backup.
If Y20–Y23 all stop switching, check the supply at C4 first. If only one channel fails, test that relay contact with a suitable bench load.
If a load stays on after the Y command turns off, safely isolate the power. Disconnect the field wiring and check the relay contact for sticking.
If a relay fails repeatedly, check the coil’s inrush, surge suppression and the other loads sharing its common.
Keep terminal photos and COM2 settings before replacing the CPU. On the replacement, verify the output groups and HMI addresses in sequence.
OtomasyonAVM PDF files and internal references
Delta DVP PLC PDF Files · Early DVP-EC3 series installation sheet (2010, English and Chinese PDF)
Delta DVP PLC series · Delta PLC overview · Used Delta equipment
External references
DVP-EC3 installation sheet – DVP48EC00R3 terminal layout (2014) · Delta DVP catalogue – EC3 model table · Delta DVP-PLC Application Manual – Programming · Delta PLC/HMI Cable Selection Guide – EC3 section