Delta DVP20EC00T3
Delta DVP20EC00T3 PLC | 12 Inputs, 8 NPN Transistor Outputs
The Delta DVP20EC00T3 is a compact PLC CPU in the DVP-EC3 series. It uses a 100–240 V AC supply and has 12 digital inputs at 24 V DC and 8 NPN transistor outputs. In small conveyors, filling and packaging machines, it can read inductive sensors and photoelectric sensors and switch DC loads in sequence.
Input addresses and transistor wiring
The onboard PLC inputs and outputs use octal addresses. Inputs are X0–X7 and X10–X13. Outputs run from Y0–Y7. Wire the S/S common for the PNP or NPN sensors in use, following Delta’s sink/source diagram. The Y outputs require the external 24 V DC auxiliary supply shown in the wiring diagram at UP0 and ZP0.
Delta’s instruction sheet specifies 0.5 A per output and 2 A per common group for resistive loads. Check the load current, suppression device and fuse against the wiring diagram. The CPU has 20 fixed digital I/O points. For analog signals or more local I/O, select a PLC family that supports the required modules.
Y0 and Y1 pulse outputs
Delta’s standard transistor output table lists 1 kHz. Its catalogue specifies independent high-speed pulse output of up to 10 kHz on Y0 and Y1 for hardware version V8.00 and later. Check the drive input type and the voltage and current requirements of the open-collector output together. For an incremental encoder, check the PLC input’s A/B counting mode and frequency limit separately.
WPLSoft, ISPSoft and 4K/8K program capacity
Use WPLSoft to read the Ladder program from the PLC to the PC and save a backup. Delta’s programming manual lists 4K (3,792 steps) for earlier EC units and 8K (7,920 steps) for EC3-8K units at V8.60 or later. For the updated unit, select EC3-8K in ISPSoft and set up the serial connection in COMMGR.
Programming cable and serial communications
The PC connects to COM1 RS-232. Delta lists UC-PRG020-12A for a USB-equipped PC and UC-MS030-01A for a PC with a serial port. For USB access, install the driver and select the COM port assigned by Windows. See Delta PLC cables for other options.
COM2 RS-485 is the industrial communications port. For Modbus RTU, match the station address, baud rate, parity and stop bits to the other device. Record the serial settings before replacing the CPU.
Related Delta models
DVP20EC00R3 has the same I/O count and relay outputs. DVP24EC00T3 provides 12 inputs and 12 transistor outputs, while DVP32EC00T3 provides 16 inputs and 16 transistor outputs. DVP16EC00R3 has 8 inputs and 8 relay outputs. Before replacing the CPU, compare output types, commons and program capacity.
Editor’s Note
When buying used, ask for clear photos of the side label and UP0/ZP0 terminals.
When sourcing a spare CPU, record the existing unit’s firmware version and the number of steps used by the program.
If the Y LED lights but the load stays off, check the external output supply and commons first. Disable machine motion for the test.
For pulse applications, test Y0 and Y1 separately with a suitable test load and measuring instrument.
If communications drop when a variable-frequency drive starts, inspect the serial cable route, sources of electromagnetic interference and cabinet grounding.
Related topics and PDF files
Delta DVP PLC files · Delta DVP-EC3 series · Delta PLC cables
External references
Delta EC3 instruction sheet (EN PDF) · Delta programming manual, EC3-8K (EN PDF) · Programming manual online reading copy (EN) · Delta PLC/HMI Cable Selection Guide, section 1.3 (EN PDF) · Delta DVP catalogue, EC3 model table (EN PDF)