Delta DVP other accessories include RS-485 connection adapters, short servo connection leads, local I/O extension cables, CAN distribution boxes, termination plugs and a backup battery. Selection depends on the connection or maintenance task within Delta DVP PLC series installations and associated field equipment. The broader range is available under Delta PLC accessories.

RS-485 adapter and servo connection leads

Delta ADP485-01 connects different connector formats to an RS-485 line. Its instruction sheet specifies surge protection, current limiting and a selectable 120 Ω terminating resistor. A DB9 connector does not establish that a port uses RS-232; read the wiring diagram for the actual electrical interface.

Delta ADPCAB03A is the 30 cm lead between ADP485-01 and an ASDA-A servo drive. Delta ADPCAB03B is the 30 cm version specified for ASDA-B. Preserve the A/B suffix when ordering and check pin assignments before considering another servo generation.

DVP local extension cables

Delta DVPACAB403 is a 0.3 m I/O extension cable specified for DVP-ES/EX. Record both the CPU and extension module codes when selecting parts for a Delta DVP-ES installation.

Delta DVPACAB4A07 is a 0.7 m cable for connecting a DVP-EH PLC and an extension module. The catalogue's EH designation does not establish compatibility with every revision. For Delta DVP-EH2 and Delta DVP-EH3 projects, follow the connection table in the applicable hardware manual.

An extension cable connects the CPU to local modules. Programming, serial communication and remote I/O networking require a separate selection based on the intended port and protocol.

DeviceNet/CANopen distribution and termination

Delta TAP-CN01, Delta TAP-CN02 and Delta TAP-CN03 organise trunk and drop connections on DeviceNet/CANopen networks. CN01 and CN02 use terminal connections; CN03 provides RJ45 drop connections. These boxes incorporate a switchable 121 Ω terminating resistor; its setting depends on the box's position along the trunk.

Delta TAP-TR01 is an RJ45, 121 Ω termination plug for applicable CANopen connections. Arrange termination at both ends of the trunk and account for existing built-in resistors. Adding a resistor at every node is not a correct installation method.

The RJ45 connectors on TAP-CN03 do not make it an Ethernet switch. Verify CAN pin assignments, network power and permitted drop lengths against the wiring instructions. See Delta CANopen cables for cable selection and Delta network connectors for related connection hardware.

DVPABT01 backup battery

Delta DVPABT01 is a 3.6 V non-rechargeable lithium backup battery. DVP catalogues list it for DVP-EH, 10SX, PM and RTU-EN01 equipment. Verify the complete device model, battery connector and polarity. Related backup hardware is covered under Delta DVP memory accessories.

Editor's Note

A small accessory can make a healthy PLC appear faulty when the wrong part is installed. Before ordering, record its label, both connected device codes and clear photographs of the connectors. Treat splices and hand-soldered repairs on an old cable as modifications requiring verification.

For intermittent communication, start with loose terminals, damaged conductors and shield connections. Disconnect both cable ends before checking continuity and shorts with power removed. Avoid spreading connector contacts with oversized meter probes. Any insulation testing must be performed without connected electronic equipment.

If an extension module repeatedly disappears, moving the cable until it works is not a repair. Remove power and inspect latches, contacts and crushed cable sections, then compare with a known-good cable of the same code. Check module supply voltage as well; see Delta DVP power supplies for the relevant hardware.

Before changing CAN termination, photograph the current switch settings. Sketch the trunk, its two ends and all drop connections. Change one item at a time and record the result after each step; this makes the cause of an intermittent fault much easier to establish.

Before replacing a battery, back up every accessible program, parameter set and retained data area. Follow the CPU manual to determine whether replacement requires power to remain on or be removed. Never recharge a non-rechargeable cell. Afterwards, check the clock, retained values and battery warning status.

PDF manuals, wiring diagrams and software

Use Delta PLC accessories files for model manuals, cable diagrams and software resources. Consult Delta PLC and HMI manuals for CPU-specific battery replacement and extension instructions. Choose Delta WPLSoft or Delta ISPSoft for program backup according to the CPU's supported tools and the existing project format.

Related topics

Delta DVP programming cables · Delta DVP communication cables · Delta DVP interfaces · Delta industrial network cables

Return to Delta PLC accessories. Browse controllers in the Delta PLC category and available equipment under second-hand Delta products.

External references: Search the Delta Download Center using the complete model code for manufacturer documentation.


Refine Search