Delta ADPCAB03B

Delta ADPCAB03B

Delta ADPCAB03B is a 30 cm connection cable between the ADP485-01 RS-485 network adapter and an ASDA-B servo drive. The manufacturer's instruction sheet lists it as ADP485-01 ↔ ASD-B connecting cable / 30 cm. Its wiring diagram shows RS-485 signals and reference connections between DB9 and Mini DIN ends. The “03” in this product code does not mean 3 metres.

ADPCAB03B carries the servo drive's serial communication connection; it is not a motor power or encoder feedback cable. The cable alone does not convert USB, RS-232 or Ethernet signals to RS-485. It appears under Delta DVP other accessories and should be assessed alongside DVP communication cables and Delta PLC accessories.

Technical arrangement and intended use

Model: ADPCAB03B. Length: 30 cm / 0.3 m. Connection: DB9 ↔ the 8-pin Mini DIN CN3 port on ASDA-B. Communication standard: RS-485. Documented pairing: ADP485-01 ↔ ASDA-B servo drive. Check the actual socket, connector orientation and complete drive code against the installed hardware.

This pairing must not be extended to every Delta servo generation. ASDA-B2 and ASDA-B3 are separate product families; the letter B alone does not establish ADPCAB03B compatibility. Likewise, ADPCAB03A is the different cable specified for ASDA-A, with a 1394-type device connector shown in the manufacturer's instructions.

Manufacturer's pin assignments

The ADPCAB03B Cable Connection section of the ADP485-01 instruction sheet shows DB9 pin 5 ↔ Mini DIN pin 8, DB9 pin 6 ↔ Mini DIN pin 1, DB9 pin 8 ↔ Mini DIN pin 3 and DB9 pin 9 ↔ Mini DIN pin 6.

In that cable drawing, DB9 line 5 is marked GND, line 6 is RS485− and line 8 is RS485+. These assignments belong to the ADPCAB03B diagram and must not be interpreted as a standard computer RS-232 DB9 pinout. Check connector numbering against the manufacturer's drawing, taking care not to confuse mating-face and solder-side views.

ASDA-B CN3 pin 6 is the SEL232/485 selection input. The ASDA-B manual specifies its connection to pin 8 GND for RS-485 operation. The cable therefore involves more than two data conductors; reference and communication-selection connections matter as well. This assignment applies to ASDA-B and must not be transferred unchanged to B2/B3 or other generations.

Separate roles of ADP485-01 and the cable

ADP485-01 is the adapter used to connect different Delta devices to an RS-485 network. The instruction sheet's protection components and selectable 120 Ω termination are adapter features; they must not be attributed to components inside ADPCAB03B. The COM1 and COM2 ports on ADP485-01 also have different pin assignments.

Network devices need compatible baud rates and data formats, with unique device addresses. Check RS-485 polarity, reference connections, shielding and termination at the two physical ends of the network. Do not add a terminator at every servo connection; set the adapter switch according to its network position.

Computer interfaces and other cable types

ADPCAB03B itself does not create a new computer COM port or have its own USB driver. For computer access to an RS-485 network, assess suitable USB-to-RS-485 interfaces such as IFD6500, or RS-232-to-RS-485/RS-422 converters such as IFD8500-A, separately. These devices do not directly replace the short servo connection cable.

PC connection products such as UC-PRG030-10A and UC-PRG020-12A have different duties and pin assignments. Select from DVP programming cables using more than DB9 housing appearance. The cable provides the physical connection; suitable software and supported communication operations are determined by the servo and controller documentation.

Editor's Note

Ask for photographs of both ends when buying. Check ADPCAB03B, 30 cm length and the Mini DIN end together. Confusing it with ADPCAB03A changes the servo-end connector, despite the similar code.

For used cables, inspect bent contacts, Mini DIN keying and DB9 fastening. Watch for damage near the plugs or previous splices. Stretching a short cable to make it reach also strains the drive socket.

Safely isolate power and disconnect both cable ends before continuity testing. Check the four connections in the manufacturer's diagram and unwanted shorts. Do not apply an insulation tester with servo or communication electronics connected.

A DB9 housing does not automatically mean RS-232; it can also carry RS-485. Compare signal definitions instead of assuming another manufacturer's A/B labels correspond directly to Delta's +/− markings.

If communication fails, check drive address, baud rate and data format first. Then inspect the adapter port, polarity and termination. A failed connection alone is insufficient reason to condemn a healthy servo drive.

Where possible, begin communication checks by reading parameters. Back up the existing servo parameters and establish the effect of any changes before writing settings on a working machine. Prevent unintended motor movement during testing.

PDF manuals and connection documents

Use our Delta PLC accessories PDF and software files page for supporting documents. ADPCAB03B appears in the Optional Connecting Cable and Cable Connection sections of the ADP485-01 Instruction Sheet. General documents are available under Delta PLC and HMI manuals. Read the servo drive's own communication manual alongside these instructions.

Related subjects

ADP485-01 · ADPCAB03A · Delta ASDA-B · Delta ASDA-A · Delta ASDA-B2 · Delta ASDA-B3 · IFD6500 · IFD8500-A

DVP communication cables · DVP programming cables · UC-PRG030-10A · UC-PRG020-12A

Navigation: Delta DVP other accessories · Delta PLC accessories · Delta DVP PLC series · Delta AS PLC series · Delta AH PLC series · Delta PLC models · Used Delta products · PDF and software files

External references

Delta ADP485-01 instructions – ADPCAB03B pin assignments and 30 cm cable · Delta DVP/TP catalogue – ADPCAB03A and ADPCAB03B pairings · Delta ASDA-B manual – CN3 pins and RS-485 selection · Delta IFD6500/IFD6530 USB-to-RS-485 instructions · Delta IFD8500-A interface and wiring instructions