Delta ASDA-B

Delta ASDA-B – 100 W to 2 kW AC Servo Drives

Delta ASDA-B is an AC servo drive series for indexing, feed and positioning axes. The 100 W to 2 kW drives pair with the ECMA motors listed in Delta’s combination table. When selecting a service replacement, check the servo system’s command type, complete motor code and supply together.

ASDA-B Models and Power Supply

The ASD-B0121-A is rated at 100 W, the ASD-B0221-A at 200 W, the ASD-B0421-A at 400 W and the ASD-B0721-A at 750 W. The ASD-B1021-A is rated at 1 kW, the ASD-B1521-A at 1.5 kW and the ASD-B2023-A at 2 kW.

The manual specifies single- or three-phase 220 V AC for the 100 W to 1.5 kW models and three-phase 220 V AC for the ASD-B2023-A. Example motor pairings include the ASD-B0421-A with ECMA-C30604□S and the ASD-B0721-A with ECMA-C30807□S. The □ marks an option position. Check the complete nameplate against the manual, including the shaft and brake options, before ordering.

CN1 Commands, CN2 Encoder and CN3 Communications

CN1 carries the control inputs and outputs. Position control uses an external pulse train. Selectable formats include pulse and direction, A/B phase and CW/CCW pulses. The maximum pulse input frequency is 500 kpps for a differential line driver and 200 kpps for open collector. The electronic gear ratio determines how far the axis moves for a given PLC command.

Speed and torque modes accept an external ±10 V analog command or a reference from internal parameters. CN2 connects the motor encoder, and CN3 handles RS-232/RS-485 serial communications. Check the CN3 diagram and the Modbus RTU or ASCII setting before connecting.

The manual specifies a 2,500 PPR incremental encoder with fourfold decoding for 10,000 counts per revolution. Check the encoder pulse count, motor feedback and closed-loop operation together during service. See the Delta 2,500 PPR ECMA motors and Delta servo cables when sourcing parts.

Braking Hardware

The manual lists a built-in regenerative resistor on the 750 W to 2 kW models. For 100 W to 400 W models, assess the need for an external braking resistor based on the application. Frequent starts and stops make regenerative energy and DC bus voltage important. If the motor has a holding brake, also check its supply and release timing.

Editor’s Note

Ask for both nameplates when buying a used 400 W set. Confirm that the full motor code, power cable and CN2 feedback cable match the parts used to test the ASD-B0421-A. On a braked motor, check that the power cable includes the brake conductors.

Save the settings before replacement. If the old drive can still be read, capture its parameters, command mode, electronic gear ratio and CN1 input assignments. After fitting the replacement, verify direction and the home position under safe conditions on the first cycle.

Test JOG and the automatic cycle separately. Have qualified personnel follow the manual’s unloaded trial-run procedure first. If JOG works and the PLC commands produce no motion, check Servo ON status, the CN1 pulse format and the controller output type. If the axis vibrates, inspect the mechanical coupling and feedback before changing the loop gain.

Include the cable when investigating ALE 11. After safe isolation and the manual’s discharge interval, inspect the CN2 latch, cable shield and grounding. If the fault occurs only during acceleration, inspect the routing of the power and encoder cables for electromagnetic interference.

Record when the drive trips on a stop. The axis may run normally on the bench. During a controlled machine test, note whether the alarm appears during acceleration or deceleration. If ALE 5 appears while slowing down, compare the braking hardware and stop time with the manual for that drive model.

ASDA-B User Manual and PDF Files

Delta ASDA-B Series User Manual – English PDF (June 2009, 321 pages). See section 1.3 for motor pairings, chapter 3 for CN1/CN2/CN3 wiring, chapter 6 for control modes, chapter 10 for troubleshooting and chapter 11 for specifications.

Existing OtomasyonAVM PDF copy · Delta Servo Manuals

Related Topics and Delta Equipment

Servo system components · Servo motor selection criteria · Servo motor maintenance

Delta PLC · Delta DVP-SV2 · Delta DOP-100 HMI · Delta ASDA-B2 · Delta ASDA-B3

External reference · Delta ASDA-B Series User Manual