Select a Delta servo cable using the complete servo drive and servo motor codes. The brake option, encoder type, motor-side connector and cable length affect the part number. In machine applications such as packaging, cutting and transfer, also check whether the cable will be fixed or moving.

Motor power, encoder and brake cables

The motor power cable carries the drive output to the motor. The encoder cable returns motor feedback to the drive. The brake lead serves the motor holding brake. Delta shows integrated brake conductors in some power cable assemblies and a separate lead in others. The holding brake holds the load at standstill. For energy returned during deceleration, see the drive’s regenerative braking circuit.

For the encoder, use the table for incremental or absolute feedback as appropriate. On an absolute system with battery backup, check the cable, battery branch and connector together. See Delta absolute encoder peripheral units for those parts.

ASDA-A2 and ECMA cable part numbers

The ASDA-A2 catalogue lists ASD-ABPW0005 as the 5 m power cable without a brake and ASD-ABPW0105 as the braked version for the ASD-A2-0421-□ and 400 W ECMA-C□0604□S example. The same row shows ASD-ABEN0005 for incremental feedback and ASD-A2EB0005 for absolute feedback. Confirm the motor and drive combination before selecting the cable row.

A2 incremental encoder · 3 m / 5 m: ASD-ABEN0003 / ASD-ABEN0005 and ASD-CAEN1003 / ASD-CAEN1005.

A2 absolute encoder · 3 m / 5 m: ASD-A2EB0003 / ASD-A2EB0005 and ASD-A2EB1003 / ASD-A2EB1005.

A2 power without brake · 3 m / 5 m: ASD-ABPW0003 / ASD-ABPW0005, ASD-CAPW1003 / ASD-CAPW1005, ASD-CAPW2203 / ASD-CAPW2205 and ASD-CAPW3203 / ASD-CAPW3205.

A2 power with brake · 3 m / 5 m: ASD-ABPW0103 / ASD-ABPW0105, ASD-CAPW1103 / ASD-CAPW1105, ASD-CAPW2303 / ASD-CAPW2305 and ASD-CAPW3303 / ASD-CAPW3305.

ASDA-B2 and ECMA cable part numbers

For the ASD-B2-0421-B and ECMA-C□0604□S, the ASDA-B2 manual lists ASDBCAPW0205 as the 5 m power cable without a brake, ASDBCAPW0305 for the braked motor and ASDBCAEN0005 for the encoder. The same drive can be paired with other ECMA frames for which Delta lists the 120/130 power cable families and the 100 encoder cable family. Read the motor row as well as the drive code.

B2 encoder · 3 m / 5 m: ASDBCAEN0003 / ASDBCAEN0005 and ASDBCAEN1003 / ASDBCAEN1005.

B2 power without brake · 3 m / 5 m: ASDBCAPW0203 / ASDBCAPW0205 and ASDBCAPW1203 / ASDBCAPW1205.

B2 power with brake · 3 m / 5 m: ASDBCAPW0303 / ASDBCAPW0305 and ASDBCAPW1303 / ASDBCAPW1305.

ASDA-A3, ASDA-B3 and communication cables

The ASDA-A3 catalogue shows ACS3-CAPW1103 as a standard power cable and ACS3-CAPF1103 as a torsion-resistant power cable for compatible 220 V F40–F80 A3/B3 motors without a brake. Both are 3 m. On ASDA-B3, ECM-A3H or ECM-A3L systems, also check the motor-side cable exit and the specified bend limit for moving applications.

For links between a PLC, motion controller and drive, use the port drawing for EtherCAT, CANopen or Modbus RS-485. See Delta servo communication units for commissioning leads and servo I/O connections for command and status signals.

Editor’s Note

Put all three part numbers on the order. Record the drive, motor and removed cable codes. For a used cable, ask for photos of both plugs. If the housings look alike, compare the pin assignments and brake conductors against the drawing.

Check the cable carrier at both travel limits. Look for pull on the motor plug, twisting and bends tighter than the cable rating. If a feedback fault always appears at the same point, enter the flex point in the maintenance record.

Compare the alarm with axis motion and cabinet events. If it appears when a contactor or another drive switches, check the power and signal routes, shield continuity and the termination specified by the manufacturer. Start the signal interference check there.

Test feedback and direction after replacement. During a controlled low-speed trial, compare the position command with actual motion. Measure homing repeatability and positioning accuracy. If a discrepancy appears, verify the connection and motor code before changing drive settings.

Observe the braked axis under load. Verify the machine’s brake release sequence. If the motor struggles to start or heats up, record speed and torque, motor temperature and axis response in the same work cycle.

Delta Servo Cable PDF downloads

ASDA-A2 Catalogue and Cable Tables · English, 2023, 72 pages. Encoder cables on PDF page 58 and 220 V motor and accessory combinations on page 62.

ASDA-B2 User Manual, Appendix A · English, 2023, 351 pages. Power cables on PDF page 335, encoder cables on page 338 and example combinations on pages 341–342.

ASDA-A3 Catalogue and A3/B3 Cable Options · English, 2025, 102 pages. Standard and torsion-resistant power cables on PDF page 87 and communication accessories on pages 98–99.

Related topics and Delta equipment

Servo system FAQs · Delta Servo STO Connections · Delta Servo Operator Panel Cables · Delta Servo Manuals