Delta DVPABT01
Delta DVPABT01 — 3.6 V Lithium PLC Backup Battery
Delta DVPABT01 is a 3.6 V, non-rechargeable lithium battery for battery-backed data and clock circuits in suitable Delta control devices. It belongs to the Delta DVP other accessories range. It does not supply normal machine power or operate PLC output loads.
Voltage alone is insufficient for selection. Compare the complete device code, hardware revision, connector, polarity and battery label. Confirm capacity and manufacturing date for the actual battery supplied; similar dimensions or a matching-looking plug do not establish interchangeability.
Basic specifications
| Property | Description |
|---|---|
| Part number | DVPABT01 |
| Nominal voltage | 3.6 V |
| Battery type | Lithium, non-rechargeable |
| Selection checks | Complete device code, connector, polarity and battery label |
Documented applications
Delta’s 2023 DVP/TP catalogue lists DVPABT01 for DVP-EH and DVP-SX. An older DVP catalogue also includes DVP-SA in the accessory description. The 2024 DVP catalogue identifies it as a 3.6 V non-rechargeable battery for RTU-EN01. These are records from the respective document generations; confirm the battery specified for the actual device.
DVP-EH2, DVP-EH3, DVP-SA2 and DVP-SX2 are separate generations. Do not extend an EH, SA or SX reference automatically to them. Use the complete model and revision within the Delta DVP PLC range.
What can a weak battery affect?
Retained information depends on the CPU memory design. The older DVP-SX instruction sheet warns about the program area, RTC and latched register data during battery replacement. Flash backup mechanisms and hardware revisions mean that data-loss behaviour is not identical across devices. Installing a new battery does not automatically restore information already lost.
For the RTU-EN01 BAT.LOW indicator, Delta identifies flashing red as low battery voltage. If the warning remains after fitting the correct battery and restarting as instructed, check the connection and device. Do not apply this indicator description as a universal alarm threshold for other CPUs.
Back up before replacement
Record the existing project, retentive register values, recipes and date/time settings first. Use the appropriate backup method with WPLSoft or ISPSoft where the PLC model is supported. COMMGR manages communication connections, while DCISoft serves relevant communication-device settings. The battery itself receives no software.
The cited older DVP-SX instructions require replacement within 3 minutes. This is not a universal replacement time for all Delta devices. Follow the target CPU manual for power state, waiting periods and retention conditions. Do not remove the existing battery before securing a backup and confirming the procedure.
Battery, memory card and power supply roles
Cards such as DVP-512FM and DVPPCC01 in the DVP memory accessories range provide backup or transfer functions for compatible equipment. A battery’s retention role differs from a memory card’s backup function. DVP power supplies provide normal operating power.
For maintenance access, select a cable from DVP programming cables that matches the device port. A backup battery requirement does not determine whether the device uses USB or serial programming.
Editor’s Note
A machine running normally with power on does not prove that its backup battery is healthy. The battery’s condition often becomes apparent after power is removed. Address BAT.LOW during planned maintenance instead of waiting for lost data.
A voltage reading near nominal does not establish remaining capacity. Avoid shorting the terminals and never connect a meter in current mode directly across the battery. Use an appropriate battery test method when its condition is uncertain.
Compare positive and negative positions even when the plug looks identical. Wire colour alone is insufficient; check the battery label, connector pins and device diagram together.
A newly purchased battery is not necessarily newly manufactured. Inspect its production date, storage condition and packaging. Do not fit a pack with damaged wrapping, leakage or corrosion.
If the warning remains after replacement, inspect for oxidised contacts, a loose connector, broken leads or a fault in the battery monitoring circuit. Verify the project and clock settings before returning the machine to production.
This battery is non-rechargeable. Do not apply an external charging voltage, solder directly on the cell or use heat as a test. Use a suitable ready-connected battery pack and follow the device’s replacement instructions.