Delta DVP-SX
Delta DVP-SX Series PLC
Delta DVP-SX is a 24 V DC slim PLC main unit combining digital control and analog I/O. Its ten built-in points comprise 4 digital inputs, 2 digital outputs, 2 analog inputs and 2 analog outputs. The DVP10SX11R and DVP10SX11T models are relevant to maintenance of existing machines and applications requiring a small number of analog channels.
Main features and model differences
DVP10SX11R has relay outputs; DVP10SX11T has NPN transistor outputs. The R/T suffix identifies the digital output stage and does not change the analog channel count. Check load wiring before replacing one output type with the other. Mechanical relay outputs are unsuitable for high-speed pulse applications.
The specified supply range is 20.4–28.8 V DC. The manufacturer instruction sheet specifies 7,920 program steps and battery-backed SRAM. A real-time clock and a two-digit seven-segment display are built in. Register D1196 can be used to set the displayed application value.
Built-in analog inputs and outputs
The two analog inputs and two analog outputs provide 12-bit conversion. The manufacturer lists −10 to +10 V voltage and −20 to +20 mA current ranges. For 0–10 V or 4–20 mA signals, check terminal wiring, channel setup and program scaling together. A signal being within the electrical range does not establish correct conversion into engineering units.
The SX instruction sheet maps D1056/D1057 to instantaneous analog input values, D1110/D1111 to averaged input values and D1116/D1117 to analog output values. These special registers for built-in channels must be distinguished from the access methods used by external analog modules.
Which software programs the DVP-SX?
WPLSoft and ISPSoft can be used. WPLSoft provides ladder program upload, download and online monitoring. In ISPSoft, select DVP-SX as the target CPU and configure the appropriate RS-232 driver in COMMGR. The installed software version must include SX in its CPU selection list.
Use ladder-based development for this older CPU; the presence of a language or feature in the ISPSoft interface does not mean that SX supports it. Keep the original WPLSoft project when moving to another environment, then compile and compare it for the intended CPU. DOPSoft edits HMI screen projects and does not load the DVP-SX PLC program. See Delta PLC software for related tools.
Programming cable and PC connection
COM1 is the RS-232 programming port with an 8-pin mini-DIN connection. The manufacturer lists DVPACAB215 (1.5 m), DVPACAB230 (3 m) and DVPACAB2A30 (3 m, DB9 at the PC end) for PC connections. Compare connector and pin assignments with the model information in Delta PLC cables.
A computer without a serial port can use a suitable USB-to-RS-232 adapter together with the DVP programming cable. Install the adapter driver, select its Windows COM number and match baud rate, data bits, parity and stop bits to the PLC settings. DVP-SX has no built-in USB or Ethernet port. The direct USB connection described for SX2 does not apply to SX.
COM2 RS-485 provides serial communication with an HMI or other devices. RS-232 and RS-485 use different electrical interfaces and cannot be substituted using the same cable. Relevant auxiliary equipment is listed under Delta DVP interfaces.
Expansion modules and system selection
Select suitable DVP expansion modules when additional channels are needed. Right-side digital modules to examine for an existing SX system include DVP08SM11N, DVP08SN11R and DVP08SP11R. Analog options include DVP04AD-S, DVP02DA-S and DVP06XA-S. Determine module limits, power budget and addressing from the applicable CPU instructions. A newer module or left-side module is not compatible solely because it carries the DVP name.
DVP-SX2 is a different generation, with different I/O capacity, memory, ports and program features. Compare terminals, analog scaling, special registers and the machine program before migration. A similar housing does not establish direct interchangeability.
Manuals and technical files
Use Delta DVP PLC files for series manuals and programming documents. Preserve the distinction between SX and SX2 and match documentation to the complete model code.
Editor's Note
Start by backing up the program on this series. Take a BAT.LOW indication seriously. When access is available, record the CPU code, communication settings and required retained data. Do not rush into battery replacement without a backup.
A plausible number on the screen does not prove that an analog channel is healthy. Use a suitable calibrator at the lower, middle and upper points of the selected range, and monitor raw and scaled values separately. Check the signal common, shielding and connections before adjusting a drifting reading.
An output LED does not establish that a relay contact works under load. Use a controlled test load to check contact operation. Sticking or intermittent contacts are important maintenance findings.
For a shorted transistor output, inspect the external coil, suppression component and field wiring as well as the output stage. Inspect the board with power removed and prevent unintended machine movement during testing.
Before condemning a CPU for a communication failure, check the cable, COM number and serial settings. A repeat test with a known-good cable can prevent unnecessary board work.
Related topics
DVP-SS · DVP-SA · DVP-SS2 · DVP-SA2 · DVP-SE · DVP-EX2 · DVP power supplies
Navigation: Delta DVP PLC series · Delta PLC · DVP PLC files
External references
Delta DVP-SX manufacturer instruction sheet, 2004, English (manufacturer document hosted in a distributor archive) · Delta WPLSoft / ISPSoft explanation · ISPSoft user manual, English