Delta DVPACAB403
Delta DVPACAB403
Delta DVPACAB403 is a 0.3-metre (30 cm / 300 mm) I/O extension cable for the DVP-ES/EX series. It connects a PLC main unit to an extension unit, or one extension unit to another. It does not add input/output channels by itself; it supports the physical arrangement of the existing extension connection.
Function in an ES/EX extension system
The manufacturer's DVP-ES/EX instruction sheet identifies DVPACAB403 for main-unit-to-extension-unit and extension-unit-to-extension-unit connections. Identify the controller under Delta DVP-ES or Delta DVP-EX, and the additional hardware under Delta DVP expansion modules. Check the complete CPU and module ordering codes together before selection.
The ES/EX description does not establish automatic ES2/EX2 compatibility. For cabinets using Delta DVP-ES2 or Delta DVP-EX2, check the hardware manual for that generation separately. Brand, similar housings or a connector that physically fits are insufficient to identify the correct cable.
Cabinet layout with a 30 cm cable
When assessing the 30 cm length, include connector orientation, cable turns and maintenance access as well as the straight distance between connection points. A tight installation or sharp fold at the connector places mechanical strain on the connection.
Permitted module count, module order, I/O addresses and power requirements depend on the CPU and extension hardware. Evaluate Delta DVP power supplies accordingly. Splicing the cable or joining cables in series to obtain a longer connection must not be assumed to form a manufacturer-approved arrangement.
Differences from DVPACAB4A07 and field cables
The manufacturer separately lists Delta DVPACAB4A07 as a 0.7-metre cable between a DVP-EH PLC and an extension module. This description for Delta DVP-EH and Delta DVP EH modules must be distinguished from DVPACAB403's ES/EX / 0.3-metre description. Do not select the two codes as interchangeable products differing only in length.
Module-to-field-terminal connections under Delta DVP / AH I/O cables and Delta external terminals serve a different purpose. DVPACAB403 is neither a computer programming cable nor a terminal module for direct sensor connections.
Software and technical documents
This passive cable requires no separate driver, firmware or download software. Select Delta WPLSoft or Delta ISPSoft according to the engineering environment supported by the CPU. Review the options under Delta PLC software and identify the main family under Delta DVP PLC series.
Start document selection at Delta PLC accessories files. Printed page 49 of the 2023-01-03 DVP/TP catalogue (PDF page 50) identifies DVPACAB403 as a 0.3-metre I/O extension cable for ES/EX. Refer to the DVP-ES/EX instruction sheet for connection arrangements, and the actual CPU and module documentation for system limits.
Editor's Note
Photograph both ends and the module order first. Record the CPU label, extension-unit code and old cable marking. Trying to decide from the connector alone after removal makes the job harder.
Disconnect power before removing or fitting the cable. Identify any separate field-side module supplies as well. Disconnect using the connector housing and any retaining mechanism, rather than pulling on the cable.
If 30 cm is insufficient, do not stretch the cable into position. Review device placement and connector orientation first. Check that the cabinet cover cannot crush the cable and that maintenance access does not strain the connection.
If consecutive modules disappear, inspect their shared connection path. Check module supplies and the connection where the fault begins. Compare with a compatible known-good cable before condemning several modules.
Appearance alone does not establish the condition of a used cable. Inspect for bent contacts, cracked housings and damage near connectors. Test continuity with both ends disconnected and follow a verified pin drawing; do not bridge pins by guesswork.
Related topics
Review supporting products under Delta DVP other accessories and Delta PLC accessories, and device documentation under Delta PLC and HMI manuals.
External references: Delta DVP/TP manufacturer catalogue — 2023-01-03 · Delta DVP-ES/EX instruction sheet — 2006-07-04, document copy.