Delta DVP ES / EX modules
Delta DVP ES / EX modules
Delta DVP ES / EX expansion modules add digital inputs and outputs to first-generation DVP-ES and DVP-EX PLC installations. XM denotes input modules, XN output modules and XP mixed I/O. When planning points for a door contact, product sensor or valve, see the guide to digital and analog inputs. The EX CPU’s built-in analog channels serve a separate function.
I/O and power supply for 17 models
DI means digital inputs and DO means digital outputs. The supply column refers to the module’s own power supply. A dash marks a combination with no model page in this category.
| I/O | Supply | Input module | Relay output | Transistor output |
|---|---|---|---|---|
| 8 DI / 0 DO | 24 V DC | DVP08XM11N | — | — |
| 16 DI / 0 DO | 24 V DC | DVP16XM11N | — | — |
| 0 DI / 8 DO | 24 V DC | — | DVP08XN11R | DVP08XN11T |
| 0 DI / 16 DO | 24 V DC | — | DVP16XN11R | DVP16XN11T |
| 0 DI / 24 DO | 24 V DC | — | DVP24XN11R | DVP24XN11T |
| 4 DI / 4 DO | 24 V DC | — | DVP08XP11R | DVP08XP11T |
| 16 DI / 8 DO | 24 V DC | — | DVP24XP11R | DVP24XP11T |
| 16 DI / 16 DO | 24 V DC | — | DVP32XP11R | DVP32XP11T |
| 16 DI / 8 DO | 100–240 V AC | — | DVP24XP00R | — |
| 16 DI / 16 DO | 100–240 V AC | — | DVP32XP00R | DVP32XP00T |
The 24XP00R and 24XP11R have the same I/O count. Both have 16 inputs and eight relay outputs. The DVP24XP00R uses 100–240 V AC, while the DVP24XP11R uses 24 V DC. Digital input signals remain 24 V DC on the AC-powered module.
How to select a module for the panel
Start with the input signal types. Count field devices such as inductive sensors, photoelectric sensors and limit switches. Match PNP/NPN sensor wiring to the module’s S/S common and the sink/source diagram. Check the NO/NC arrangement of mechanical contacts against the signal state expected by the PLC program.
Match outputs to the load. In this table, R models have relay contacts and T models have DC transistor outputs. For a valve or contactor coil, check the channel current, total current per common and suitable coil suppression. Choose the fuse and any interposing device for the load circuit. An analog speed reference needs a suitable analog signal output.
Check the full model code before moving to a newer generation. The DVP24XP00R, DVP24XP11R and DVP24XP200R each have 16 inputs and eight relay outputs. Compare the CPU expansion connection, supply, terminals and addressing with the DVP ES2 / EX2 module documentation. Delta discontinued the original DVP-ES CPU series in July 2018 and lists ES2 as its successor.
Programming, cables and X/Y addresses
Access the program through the host CPU. WPLSoft is used on original ES/EX machines. Before using ISPSoft, check the CPU target and project compatibility. The X and Y points of these digital modules are used in the host PLC program. Use the ladder monitor to observe input and output states.
For the ES/EX CPUs listed by Delta, COM1 RS-232 supports the UC-PRG020-12A for USB computers and the UC-MS020-01A for a physical serial port. Check the exact CPU in the Delta PLC cable guide. Delta’s DVPACAB403 is an expansion cable for compatible units. See the RS-232, RS-422 and RS-485 comparison when identifying a computer port.
Addressing example. With a four-input, four-output DVP08XP11R as the first expansion on a DVP24ES00R2, its physical channels appear at X20–X23 / Y20–Y23. Octal addressing reserves an eight-address block in each direction. The next suitable input/output module starts at X30 / Y30. Use the CPU’s address table for the first expansion addresses on DVP40ES and DVP60ES.
Editor’s Note
Check the label and the terminals before buying. Ask for photos that show the 00 or 11 suffix clearly. Compare the L/N or DC supply terminals with the existing panel drawing.
Photograph the module order before removal. Back up the PLC program and mark the plugs. A change in module order can move a sensor to a different PLC address.
Test one input, then one output. Compare the module LED with its PLC X address. After safely isolating the machine loads, check one Y channel with a suitable test load. Measurement and testing guide
Check the common if an entire output group fails. Measure the group supply. Isolate power before checking continuity. If a relay clicks, also verify that its contact conducts under load.
If inputs flicker when a drive starts, inspect cable routing. Check the separation between sensor and power cables, shield connections and cabinet grounding. See the electromagnetic interference guide for troubleshooting.
Related Delta pages
Delta DVP expansion modules · DVP E2 modules · Delta DVP remote I/O modules · Delta PLC accessories
For signals collected over a network at the far end of a machine, see remote I/O and industrial communications.
Delta DVP PLC series · Delta PLC · Used Delta Automation
OtomasyonAVM PDF files
Delta DVP PLC PDF files · DVP-ES wiring guide (PDF) · Original DVP-ES/EX guide and module tables (PDF)
External references
Delta ES/EX digital expansion instruction sheet (PDF) · Delta DVP application manual, X/Y addressing (EN PDF) · Delta PLC/HMI cable guide (EN PDF) · Delta DVP-ES product and lifecycle status