Delta DVP08XM11N

Delta DVP08XM11N – 8 Digital Input ES/EX Expansion Module

Delta DVP08XM11N is an expansion module in the DVP ES/EX family, providing eight 24 V DC digital inputs and no outputs. It passes pushbutton, limit-switch and sensor states to a suitable host PLC rather than running an independent user program.

Within the DVP expansion range, XM identifies an input unit and N indicates no output. Do not assign analog measurement, load switching or the host CPU’s high-speed input features to this module.

Technical specifications

I/O: 8 inputs, 0 outputs. Supply: nominal 24 V DC. Inputs: sink/source wiring through S/S, nominally 5 mA/channel. The ES/EX DIDO sheet specifies an ON level above 16.5 V DC and an OFF level below 8 V DC.

Input response: approximately 20 ms. Indication/isolation: input LEDs and optocouplers. Dimensions: approximately 42 × 100 × 82 mm (width × height × depth). Installation uses 35 mm DIN rail or suitable screw mounting.

PNP, NPN and dry-contact wiring

For a PNP sensor, connect S/S to 0 V; the sensor applies +24 V to its X input. For an NPN sensor, connect S/S to +24 V; the sensor pulls its X input towards 0 V. Use a consistent arrangement within the common group. Establish sensor power, module power and the signal reference according to the terminal diagram.

For a dry-contact test, switch the appropriate voltage to the X input according to the chosen S/S arrangement. Do not apply 230 V AC to X inputs. There are no Y outputs for directly operating a valve or relay coil.

Host PLC and addressing

The product is listed in the original DVP-ES and DVP-EX documents. Check the exact CPU code, expansion connection and power budget. DVP08XM211N belongs to the DVP-ES2/DVP-EX2 generation and is a different ordering code. Do not assume universal compatibility across all DVP series.

Local terminals are labelled X0–X7. As the first digital expansion after a suitable DVP32ES00R2, an example system allocation is X20–X27. Preceding modules or another CPU can change the starting address. X/Y addresses use octal notation: X27 is followed by X30.

Programming software and cable

No separate program is downloaded to DVP08XM11N. Its inputs are used in the host CPU program. The legacy ES/EX manufacturer guide identifies WPLSoft. If using ISPSoft, verify host CPU and project-version support. Select the appropriate Delta PLC software for the main unit.

The guide lists DVPACAB215 (1.5 m) and DVPACAB230 (3 m) for PC connections to the host CPU’s RS-232 port. A PC without a serial port requires a suitable USB-to-RS-232 adapter and driver; verify pinout and communication settings. Programming cables serve a different purpose from the DVPACAB403 expansion cable. Do not connect a PC cable to the expansion socket.

Differences from related models

DVP16XM11N provides 16 inputs. DVP08XP11R provides 4 inputs/4 relay outputs, while DVP08XP11T provides 4 inputs/4 transistor outputs. DVP08XN11R and DVP08XN11T add eight outputs instead of inputs. These are not direct equivalents.

Editor’s Note – Input tests and used equipment

Check the complete XM11N label first. A similar XN or XP enclosure does not identify the same input module.

Test all eight channels with a suitable CPU. Check both the input LED and the correct X bit; evidence that the module powers up is insufficient.

If every input is unresponsive, check the 24 V supply, S/S wiring, expansion connection and actual addresses before rejecting the module.

If an input remains active with its sensor OFF, investigate leakage current, moisture, common wiring and the cable. Disconnect the sensor and perform a controlled test with a suitable dry contact.

If short pulses are missed, measure their duration first. Trying to use this module as a fast encoder interface can make working inputs appear faulty.

For used equipment, request an eight-channel test record and clear terminal photographs. Mark the wiring before replacement and disconnect power before fitting or removing the module.

PDF documents and related topics

Shared documents are tracked on our Delta DVP PLC PDF files page. The original ES/EX manufacturer guide on our site includes this model. The 2013 ES/EX DIDO sheet and 2006 ES/EX guide are associated with DVP08XM11N, with document language and edition recorded separately.

For combined inputs and outputs, compare DVP24XP11R, DVP24XP11T and DVP32XP11R. DVP16XN11R serves the separate task of adding outputs. Check supply and terminal differences.

Navigation: Delta main page · Delta PLC · ES/EX modules · DVP PDF archive

External references

Delta ES/EX DIDO sheet – 5011671702-ED02, 15 August 2013; archived manufacturer document in English/Chinese. Compare older specifications with the equipment label and revision.