Delta DVP08XN11T
Delta DVP08XN11T – 8-output NPN transistor ES/EX expansion module
Delta DVP08XN11T is a digital expansion module providing eight NPN open-collector transistor outputs for the original DVP-ES/EX family. It has no digital inputs. It extends the output capacity of the connected PLC CPU and does not execute a separate user program.
Typical machine automation duties include controlling suitably rated DC relays, valve coils and indicator lamps. Sensor signals are read through the CPU or a suitable input module; DVP08XN11T applies the resulting output commands to field loads.
Model identification and host family
The code identifies 08 points, X expansion, N digital outputs only, 11 DC-powered H-type construction and T transistor outputs. It belongs to the ES/EX expansion module family and should be assessed with DVP-ES and DVP-EX documentation. Confirm the exact CPU and interface when moving to ES2/EX2 or another host. DVP08XN211T is a different ordering code.
Power supply and enclosure
The 2008 ES/EX digital expansion sheet specifies 24 VDC, −15%/+20%, equivalent to 20.4–28.8 VDC. Maximum module consumption listed for the DVP08XN11 group is 5 W. External coils and lamps are additional loads; size the power supply for the complete system.
Connect power to +24V and 0V with correct polarity, and complete the load supply and output common circuit. Compare the rated voltage with a real measurement. An illuminated power LED does not establish that every load circuit is correctly wired.
The enclosure measures approximately 42 mm wide × 100 mm high × 82 mm deep. Mount it on 35 mm DIN rail or use the specified screw mounting. The operating temperature range is 0–55°C, with output-current derating at higher temperatures.
Y0–Y7 outputs and C0 common
The local outputs are Y0–Y7 with a common terminal C0. Basic NPN wiring is +V → DC load → Y output, with C0 connected to the load supply's 0 V. The enabled transistor sinks current. In NPN/PNP terminology this is an NPN output; it does not generate +24 V and is not a dry contact.
The digital expansion sheet specifies transistor loads up to 30 VDC. Maximum channel current is 0.3 A at 40°C, 0.2 A at 45°C, 0.15 A at 50°C and 0.1 A at 55°C. The C0 common limit is 2 A. Both the individual channel limits and the common limit must be respected.
Example: eight simultaneous 0.3 A loads at 40°C total 2.4 A, exceeding the common rating. Keep the combined current at or below 2 A when all eight channels operate. At 55°C, the 0.1 A channel limit reduces the maximum eight-channel total to 0.8 A.
Check inrush as well as continuous current when driving DC relay or contactor coils. Use a suitable suppression diode or the coil manufacturer's recommended suppression circuit for inductive loads. Provide appropriate fuse protection and do not assume the transistor survives a load short circuit.
The expansion sheet lists approximately 15 µs turn-on and 25 µs turn-off. CPU scan time and I/O refresh also affect actual response. These switching figures do not provide high-speed encoder counting or an independent servo pulse-generation function.
I/O addressing
The module uses eight CPU Y addresses and adds no physical X inputs. Local Y0–Y7 markings do not mean that the CPU addresses must also be Y0–Y7. The CPU and preceding digital expansions determine the start address; numbering is octal.
Example: under the ES/EX sheet's rules, an initial digital output expansion on a 14ES or 32ES CPU can occupy Y20–Y27. A 60ES CPU starts its first expansion outputs at Y30–Y37. Preceding modules change the allocation; verify the actual project online.
Programming software and cables
No separate program is downloaded to DVP08XN11T. Perform PLC programming through the host CPU. Original ES/EX documents identify WPLSoft; its Y outputs are controlled in the CPU's ladder program. If using ISPSoft, verify exact CPU support in the selected version and configure communication through COMMGR.
CPU programming connection: the legacy ES/EX manual lists DVPACAB2A30, 3 m. The 2019 cable guide lists UC-MS020-01A, 2 m and UC-MS030-01A, 3 m for ES/EX CPU COM1. The connection uses an 8-pin mini-DIN PLC connector and DB9 RS-232 PC interface. A USB-only computer needs a suitable USB-to-RS-232 adapter and driver.
The ES/EX CPU diagram also lists UC-PRG020-12A, a 2 m USB programming cable, requiring a compatible driver and correct COM selection. Connect these cables to the CPU. DVP08XN11T has no independent programming port or RS-485 station address.
Expansion connection: legacy ES/EX documents identify DVPACAB403, 30 cm as a CPU-to-expansion or expansion-to-expansion I/O cable. It serves a different purpose from the computer programming cable. Isolate power before inspecting the connector, orientation and pins.
Field checks
Check power and the expansion connection first, followed by C0 and the load supply. If an output LED is on but its load remains off, check the actual Y address, field circuit and output device. Provide proper grounding, ventilation and separation between power and signal cables.
Editor's Note
Read the complete DVP08XN11T label. Confusing XN with XM changes an output module into an input module; changing T to R changes the output technology. A clear label photograph and a separate test of each channel are valuable when buying used equipment.
If all outputs fail, inspect C0, 0 V, load power and the expansion cable before assuming that eight transistors have failed. Missing common wiring can leave LEDs illuminated while every field load remains off.
Start with a small, known DC test load. For a resistor load, calculate I=V/R and P=V²/R and allow adequate resistor power margin. An unloaded voltage reading alone does not prove that the output works under load.
For one damaged channel, inspect its coil, wiring and suppression device as well. Replacing the transistor alone will not resolve a continuing field short. Check the total current of all eight channels together with the operating temperature.
Back up the CPU program and photograph the module order and wiring. Establish a safe test arrangement that prevents unexpected machine movement. Remove temporary forces afterward and test each output with its intended load.
Related modules and topics
DVP08XN11R: eight relay outputs. DVP16XN11T: 16 transistor outputs. DVP24XN11T: 24 transistor outputs. DVP08XP11T: four inputs/four transistor outputs. DVP08XM11N is a different, eight-input module. These are functional comparisons, not guaranteed drop-in replacements; check the CPU, supply, commons and addresses.
PDF files and manuals
Use our Delta DVP PLC PDF files page for documents. The ES/EX general sheet hosted on our site – English, 2006 also lists this model. Use the dedicated digital expansion sheet for detailed module ratings.
Navigation: DVP08XN11T main page · ES/EX modules · DVP PLC series · Delta PLC models · Used Delta products · DVP PDF files
External references
Delta ES/EX DIDO digital expansion sheet – 2008, English/Chinese · Delta legacy ES/EX technical manual – English · Delta PLC/HMI Cable Selection Guide – 2019, English