Delta DVP remote I/O modules
Delta DVP remote I/O modules
Delta DVP remote I/O modules collect signals where they originate on a machine or production line. Input and output cards in the remote cabinet attach to the RTU station, which exchanges data with the PLC over the field network. Sensors and valves at the far end of a conveyor can therefore be wired to a nearby cabinet. See how remote I/O works and industrial communications for an overview.
Which Delta RTU fits your network?
Start with the protocol supported by the host controller. When replacing an existing station, use the model pages below to check wiring, software and I/O mapping.
| Model | Field network | Selection and setup |
|---|---|---|
| RTU-485 | Modbus over RS-485 | Serial station for Modbus RTU or Modbus ASCII. Check the DIP switches for the station address and serial settings. Delta's manual lists up to 128 digital inputs, 128 digital outputs and eight special modules. |
| RTU-EN01 | Ethernet / Modbus TCP | IP-based remote station. Use DCISoft to configure the network and attached modules. Delta's manual specifies up to 16 digital modules, 256 digital points in total and eight analog modules. |
| RTU-DNET | DeviceNet | Remote station for an installed DeviceNet network. Delta’s example uses DVPDNET-SL as the scanner. In DeviceNet Builder, check the EDS file, node address, scan list and I/O size. |
| RTU-PD01 | PROFIBUS DP | Remote station for an installed DP network. Import the GSD file into the DP master project. Delta’s Siemens example uses STEP 7 HW Config. In TIA Portal projects with DP master support, add the GSD to the hardware catalogue. |
Lifecycle status for installed systems. Delta discontinued the RTU-PD01 in February 2023 and the RTU-DNET in June 2024. When sourcing a spare, record the existing network type, device description file and PLC I/O mapping.
The Delta DVP catalogue also lists RTU-CN01 for CANopen and RTU-ECAT for EtherCAT. When reviewing Ethernet infrastructure, see how switches and hubs differ. Select the RTU by the controller’s network protocol, its role on that network and the supported module list.
Which input and output cards fit the station?
Choose right-side cards from the RTU’s own compatibility table. For DVP Slim digital modules, check the input count, PNP/NPN wiring and relay or transistor output type. For DVP Slim analog modules, check 0–10 V or 4–20 mA ranges. For temperature modules, check the Pt100 or thermocouple input type. See digital and analog inputs and analog signal types when selecting modules.
Conveyor example. At the end of a line, a photoelectric sensor detects the product, an inductive sensor detects metal and a limit switch confirms the end of travel. See PNP/NPN sensors for sensor type, sink/source wiring for the common terminal and NO/NC contacts for contact logic. The PLC reads the mapped remote inputs and commands a diverter valve through the output card. For coils, check the card’s rating and whether an interposing relay is needed.
Commissioning and I/O mapping
Configure the station first. Record the RTU model, address, power terminals and the left-to-right card order. Check speed and framing on serial links, IP address and subnet mask on Ethernet, and the node address and project definition on DeviceNet or PROFIBUS.
Trace one signal end to end. Change a sensor state and watch the card LED, the RTU data and its PLC tag. Test the outputs one at a time after safely isolating the machine loads. Record the physical channel, network bit or register and PLC tag together.
Open the PLC project in the tool supported by its CPU. WPLSoft and ISPSoft are host PLC programming tools. DCISoft configures the RTU-EN01 network and station. In supported DVP-SE applications, RTU Mapping can map remote data to the PLC’s M bits and D registers.
Editor’s Note
Ask for a photo of the right side when buying used. Look at the expansion connector, terminal blocks and address switches. A bent pin can cause intermittent station faults.
Record the card order and settings before removal. Photograph the address and network settings. Back up the host PLC project and the station configuration if available.
Start at the LED and finish at the PLC tag. If the card input changes but the PLC tag stays fixed, check the matching bit or register on the network. Measurement and testing guide
Check cable routing if faults start with the drive. Look for fieldbus and motor cables running side by side. Inspect shielding and cabinet grounding.
Test what the machine does when communication drops. Use the manual to confirm the station’s supported output behaviour. Verify the machine’s expected safe state during a controlled loss and restoration of communication.
Frequently asked questions
Can adding a card change the PLC address? The card type and physical order can affect the data layout. After adding a card, compare the station map with the bit or register read by the PLC.
Are the RTU-EN01 and RTU-485 interchangeable? The RTU-EN01 uses Modbus TCP on its primary network. The RTU-485 uses serial Modbus. For a migration, check controller protocol support, cabling and mapping.
Related Delta pages
DVP expansion modules · DVP Slim communication modules · Delta PLC accessories · Delta TP panels and remote I/O
Delta PLC · Delta DVP PLC series · Used Delta Automation
OtomasyonAVM PDFs and device files
Delta DVP PLC PDF files · RTU-EN01 operation manual (EN PDF) · RTU-DNET application manual (EN PDF) · Delta device description files
External references
Delta DVP and TP catalogue (EN PDF) · RTU-485 operation manual (EN PDF) · RTU-PD01 operation manual (EN PDF) · Delta fieldbus products and lifecycle status