Delta DVP08XP11T
Delta DVP08XP11T – 4 Digital Inputs and 4 NPN Transistor Outputs
Delta DVP08XP11T is a digital extension module for legacy DVP-ES and DVP-EX systems, providing 4 digital inputs plus 4 transistor outputs. Its eight points are combined I/O. The PLC program runs in the main CPU; this module increases the system’s input/output capacity.
Typical uses include pushbuttons, limit switches, inductive sensors, photoelectric sensors and suitable DC control loads. Keep the exact legacy code DVP08XP11T separate from later codes such as DVP08XP211T. Confirm any proposed ES2/EX2, ES3 or EH connection from the applicable compatibility documents.
Supply, dimensions and inputs
Supply: nominal 24 V DC. The 2013 digital-extension sheet gives this model group a 20.4–28.8 V DC range and 5 W maximum consumption. Approximate dimensions are 42 mm wide × 100 mm high × 82 mm deep; operating temperature is 0–55 °C. Check DIN rail retention and grounding during installation.
Inputs: four 24 V DC sink/source inputs, approximately 5 mA input current and 20 ms response, with optocoupler isolation and status LEDs. These are digital inputs for ordinary on/off signals. The 10 ms input figure in an older general CPU sheet should not be transferred to this extension module.
Terminals and PNP/NPN wiring
The manufacturer’s terminal drawing identifies +24V and 0V supply terminals, S/S input common, X0–X3 inputs and the C0 / Y0–Y3 output group. +24V is an operating-power input on this DC-powered module. S/S and C0 have separate signal and load-common functions.
For PNP/NPN input wiring, connect S/S to 0 V for PNP-output sensors, or to +24 V for NPN-output sensors. Input flexibility does not change the output technology. DVP08XP11T uses NPN sinking, open-collector outputs: connect C0 to the load supply’s 0 V, with each load between its positive supply and the relevant Y terminal. Use suitable DC loads.
Output current and switching limits
The output voltage ceiling is 30 V DC. Per-channel current ratings are 0.3 A at 40 °C, 0.2 A at 45 °C, 0.15 A at 50 °C and 0.1 A at 55 °C. The 2 A per common limit applies alongside every channel limit. Check inrush and cabinet temperature; use appropriate fuses and reverse-parallel diode suppression for suitable DC coils.
The sheet specifies approximately 15 µs turn-on / 25 µs turn-off transitions and a switching frequency of up to 1 kHz, affected by CPU scan time. These electrical figures alone do not establish high-speed pulse or positioning support on an extension channel. Check the CPU instruction and output restrictions for the proposed application.
Addressing and end-of-chain placement
X0–X3 and Y0–Y3 are local terminal labels. In an illustrative first digital extension after a 14ES CPU, the physical channels can occupy X20–X23 and Y20–Y23. Actual allocation depends on the CPU and preceding modules. DVP X/Y numbering is octal.
The manufacturer recommends placing DVP08XP11R/T at the end of the extension chain. Four physical channels can occupy an eight-address block, leaving the upper four addresses unused. Record the installed allocation before moving modules, and do not interpret reserved addresses as additional physical terminals.
Programming software and cables
DVP08XP11T has no separately downloaded program. The legacy ES/EX manufacturer sheet names WPLSoft. If using ISPSoft, verify that the exact host CPU appears in that release’s target list. PLC programming and language selection follow the main CPU and existing project.
For the CPU’s COM1 RS-232, 8-pin mini-DIN interface, UC-PRG020-12A is a 2 m active USB programming cable. Install the appropriate USB driver and select the resulting COM port. UC-MS020-01A is a serial-cable option for a real RS-232 computer port; a USB-only computer additionally needs a suitable USB-to-RS-232 converter.
DVPACAB403 is a 30 cm I/O extension cable, with a different purpose from the PC programming cable. Connect the computer to the main CPU. The extension module has no independent RS-485/Modbus station address or separate communication program.
Nearby model codes
DVP08XP11R has 4 inputs and 4 relay outputs. DVP08XM11N provides 8 inputs only; DVP08XN11T provides 8 transistor outputs only. DVP24XP11T provides 16 inputs and 8 transistor outputs. Compare these functions and their wiring before considering a replacement.
Editor’s Note
Read the full nameplate first. 08XP11T and 08XP11R use different output circuits; the extra digit in the later 08XP211T code also matters.
An illuminated output LED does not prove that its transistor switches a load correctly. Check each Y channel with a correctly wired, low-voltage, current-limited test load.
If all four outputs fail together, check C0, load power and the 0 V return first. A shared wiring fault can make every channel appear defective.
During fault finding, measure +24V/0V under load, then compare the sensor signal, S/S, input LED and monitored CPU bit in sequence.
After a transistor repair, inspect the driver stage, board damage and connected coil current. Find the cause of a short circuit before reconnecting the load.
Back up the program and record the address allocation before moving the module. Remove all forced states after testing, and provide the required emergency-stop functions within the machine safety design.
PDF files and manuals
Use our Delta DVP PLC PDF files page for the collected documents. Our existing Delta ES/EX general instruction sheet covers the legacy CPU and extension family. Use the applicable digital-extension sheet for module I/O ratings.
Related topics
Browse Delta ES/EX extension modules, Delta DVP extension modules and Delta DVP PLC series for related devices.
Delta home | Delta PLC models | DVP-ES | DVP-EX | DVP PDF files
External references
Delta DVP-ES/EX DIDO manufacturer sheet – 2013-08-15, ED02; Delta PLC/HMI Cable Selection Guide – ES/EX CPU connections. Documents are in English; the digital-extension sheet also contains Chinese sections.