Delta AH temperature / motion modules
Delta AH Temperature and Motion Modules
This Delta AH500 category includes four temperature measurement modules, two high-speed counters and four motion control modules. Choose the module according to the task: reading an RTD or thermocouple, counting encoder pulses, or sending motion commands to servo axes. Start with the field signal, then determine the required channel or axis count.
RTD and thermocouple modules
AH04PT-5A — Four-channel RTD input module for Pt100, Pt1000, Ni100 and Ni1000 sensors. Select the wiring diagram for the sensor’s two-, three- or four-wire configuration. See Pt100 sensor basics.
AH08PTG-5A — Eight-channel RTD input module with channel-to-channel isolation. Supports two-, three- and four-wire measurement connections.
AH04TC-5A — Four-channel thermocouple input module.
AH08TC-5A — Eight-channel thermocouple input module. Both TC models support types J, K, R, S, T, E and N. Check the manual for the exact model’s terminal layout and channel settings.
Encoder inputs and high-speed counting
AH02HC-5A — Two-channel high-speed counter. Delta specifies pulse input up to 200 kHz under the applicable input conditions.
AH04HC-5A — Four-channel high-speed counter with pulse input up to 200 kHz under the applicable input conditions. For A/B phase encoders, match the counting mode and electrical signal type to the module’s wiring table.
Pulse-train motion modules
AH05PM-5A — Two-axis pulse-train positioning module. Supports pulse output up to 1 MHz and two-axis linear or circular interpolation.
AH10PM-5A — Six-axis pulse-train motion module. Four axes support up to 1 MHz and the other two up to 200 kHz. Check the electrical output type of the axis when matching it to a drive.
AH15PM-5A — Four-axis motion module with pulse output up to 1 MHz. LSP/LSN inputs accept positive and negative limit switch signals.
DMCNET motion control
AH20MC-5A — Controls 12 physical axes over DMCNET. Delta’s manual specifies the DMCNET-capable ASDA-A2-F drive variant. For EtherCAT systems, see Delta AH motion controllers.
Software, cables and terminal blocks
Use HWCONFIG in ISPSoft for the host PLC project and rack configuration, and COMMGR for the PC-to-PLC connection. Select a compatible PMSoft version for the PM or MC module’s motion program and parameters.
Delta specifies the UC-ET010-13B cable and UB-10-IO16C terminal block for field I/O on the AH04HC-5A and AH20MC-5A. The AH10PM-5A and AH15PM-5A use the UC-ET010-15B cable. Their external terminal blocks are the UB-10-IO24C and UB-10-IO34C, respectively.
Manuals and PDF files
Delta AH500 Module Manual (PDF, English) — Chapter 5 covers RTDs, Chapter 6 covers thermocouples, and Chapter 7 covers high-speed counter wiring and settings.
Delta AH500 Motion Control Module Manual (PDF, English) — Axis specifications, wiring and programming for the AH05PM, AH10PM, AH15PM and AH20MC. See the Delta AH PLC PDF files archive for other documents in the range.
Editor’s Note
Start with the sensor label. Record the wire count for a Pt100 and the letter code for a thermocouple.
When choosing a counter module, record the channel count, encoder output type, A/B phases and expected pulse frequency.
Check the servo drive’s full part number and command interface. For pulse-train control, check the axis’s electrical output type as well.
When buying a used module, ask whether the field cable and external terminal block are included.
Record the rack layout and channel parameters before replacement. For a motion module, back up the PMSoft project and axis settings as well.
Related topics
AH analog modules · AH digital modules · AH I/O cables · AH external terminals · Used analog modules
More in this range · AH expansion modules · Delta AH PLC series · Delta PLC models · Used Delta equipment
External references
Delta AH Series manufacturer catalogue · AH500 Module Manual (distributor archive) · AH500 Motion Control Module Manual (distributor archive)