Delta AH05PM-5A

Delta AH05PM-5A | Two-Axis Pulse Train Motion Control Module

The Delta AH05PM-5A is a motion control module for positioning two physical axes in a Delta AH500 PLC system. It sends differential pulse commands to compatible servo drives. It supports pulse output up to 1 MHz, 64K steps of program memory and two-axis linear and circular interpolation. Typical applications include X-Y positioning tables, cutting and drilling machines, and two-axis handling equipment.

Pulse outputs and field wiring

Output modes: Pulse/Direction, FP(CW)/RP(CCW) and A/B phase. Axis 1 uses differential pairs Y0.0± and Y0.1±, and axis 2 uses Y0.2± and Y0.3±. The selected mode determines the function of each pair. Match the drive’s differential input, accepted pulse rate and command format to the application. The guides to line-driver signals and stepper motor systems cover related pulse interfaces.

Homing inputs: In motion mode, X0.0 and X0.1 are the PG inputs for axes 1 and 2, respectively. X0.12 and X0.13 are their home sensor (DOG) inputs. X0.8 and X0.9 can serve a manual pulse generator (MPG). Check the terminal assignments for the operating mode used in the project. For a coordinated path, verify axis scaling together with the interpolation settings.

PMSoft, Mini USB and ISPSoft

Use Delta PMSoft to edit and transfer the module’s motion program. For a direct connection, use the module’s Mini USB port and a USB data cable. Use HWCONFIG in ISPSoft to configure the module and its parameters in the PLC rack. For an indirect connection through the CPU, match the slot and CPU-to-module data exchange settings to the project. The Delta PLC software page covers the engineering tools.

Manuals and PDF downloads

Delta AH500 Motion Control Module Manual — PDF · English · 2016-08-15 · 551 pages. See Section 1.1 for AH05PM-5A specifications, Chapter 2 for terminals and wiring, and Section 2.3 for Mini USB communication.

Delta PMSoft User Manual — PDF · English · 2014-04-21 · 327 pages. See PDF pages 61–65 for direct connections and connections through the CPU.

See also the Delta AH PLC PDF library for other documents in the series.

Editor's Note

On a used card, check the full AH05PM-5A part number and inspect the removable terminal block and backplane connector.

Before replacement, back up the PMSoft project and ISPSoft/HWCONFIG settings. Record the original slot and axis parameters.

If the drive shows ready and the axis stays still, start with the pulse mode, differential pairs and the drive’s selected command source.

If homing is inconsistent, watch the DOG sensor and PG signal separately and compare which input each axis uses.

In a safe test setup, check each axis individually at low speed. Verify direction, homing and distance scaling before testing coordinated movement.

Related topics

The AH15PM-5A is a four-axis pulse module and the AH10PM-5A is a six-axis pulse module. The AH20MC-5A uses DMCNET for motion control. For pulse counting, see the AH02HC-5A and AH04HC-5A high-speed counters.

AH temperature and motion modules · AH expansion modules · AH power supplies · AH Motion backplanes · Delta PLC accessories

More from OtomasyonAVM
Delta AH PLC series · Delta PLC · Used Delta equipment

External references
Delta Electronics manual — distributor copy · Delta ISPSoft manual — motion module integration