Delta UC-ET010-15B

Delta UC-ET010-15B 1-Metre MDR50 I/O Cable

Delta UC-ET010-15B is a 1-metre I/O cable connecting a motion control module to an external terminal board. It has a female MDR50, 50-contact connector at each end and belongs to the Delta AH I/O cables group.

Module and terminal combinations

The manufacturer's combinations are AH10PM-5A ↔ UB-10-IO24C and AH15PM-5A ↔ UB-10-IO34C. The cable connects the module's CN1 external I/O port to the appropriate terminal board.

When selecting for AH motion controllers, check the complete module code and terminal board model together. Two modules sharing a cable does not establish interchangeability between their terminal boards.

MDR50 orientation and signal assignments

For example, the manufacturer's diagram assigns AH10PM-5A pin 1 to C3 and AH15PM-5A pin 1 to Y0.11. Select the pin table for the actual module.

50 contacts do not represent 50 independent I/O channels. Follow the module diagram for commons, signal pairs and unused pins. Distinguish the connector's contact-face view from its cable-side view.

During repair or continuity checks, identify conductors by pin assignment rather than colour alone. Match the drawing's viewing direction and record each connection. Do not force a mismatched connector into a socket.

Differences from other AH I/O cables

UC-ET010-13B uses MDR36 and appears with AH04HC-5A and AH20MC-5A connecting to UB-10-IO16C. Preserve the MDR50 arrangement when selecting UC-ET010-15B.

UC-ET010-33B belongs to the DB37 group, while UC-ET010-24B uses IDC40. When comparing DVP / AH I/O cables, check connector family, pin assignment and terminal board together.

Installation and commissioning

Disconnect the PLC and external field supplies before connecting or removing the cable. Align the plug, verify that its locks engage and keep tension away from cable entries.

Route the cable separately from motor and drive power wiring. Secure machine movements before commissioning and verify inputs and outputs against the relevant channel table.

Editor's Note

Select the cable and terminal board together. AH10PM and AH15PM can use the same cable while requiring different terminal combinations. Specify equipment codes at both ends rather than relying on a cable photograph.

Inspect the MDR connectors carefully on a used cable. Bent contacts, cracked bodies and damaged locks can cause intermittent faults. Hold the connector body instead of pulling on the cable when unplugging.

Disconnect both ends before continuity testing. Check the required conductors and shorts between neighbouring contacts. Gently flex the connector entries during measurement to detect intermittent breaks.

Trace a failed channel before replacing the entire module. Check its terminal connection, common and cable conductor. If several channels disappear together, also inspect connector seating and shared connections.

Verify pulse and direction wiring against the diagram. Do not rearrange signal pairs or commons by guesswork. Secure the load and mechanical limits before testing axis movement.

Measure the actual cable route. The manufacturer's guide lists this model as 1 metre. Check the label and physical length of a used cable and allow maintenance slack around wiring ducts.

PDF wiring drawings

Use our Delta PLC accessories PDF and software files page for documentation. In the Delta PLC/HMI Cable Selection Guide, consult the module combinations in Section 2.4, the cable drawing in Section 2.5, Figure 15, and the appropriate module pin table together.