Delta UC-ET010-24B
Delta UC-ET010-24B — 1 m Shielded IDC40–IDC40 I/O Cable
Delta UC-ET010-24B is a 1-metre shielded I/O cable connecting a PLC I/O module to an external terminal module. It has a 40-pin IDC/MIL connection at each end. It belongs to the Delta DVP / AH I/O cables range and routes existing input/output signals to a suitable terminal board.
Main characteristics
| Item | Description |
|---|---|
| Model | UC-ET010-24B |
| Nominal length | 1 m |
| Connection | IDC40 ↔ IDC40 |
| Cable construction | Shielded |
| Application | I/O module to external terminal module |
| Connector contacts | 40 at each end; channel functions depend on the connected module |
Documented DVP connections
| I/O module | External terminal module | Application |
|---|---|---|
| DVP32SM11N | UB-10-ID32A / DVPAETB-ID32A | Digital input connection |
| DVP32SN11TN | UB-10-OT32A / DVPAETB-OT32A | Transistor output connection |
Select the cable and terminal board together for these arrangements. Input commons and output supply references serve different functions. In a Delta DVP PLC system, read the complete I/O module code before checking the wiring diagram.
AS and AH applications
The AS hardware manual lists the 24B family for AS32AM10N-A, AS64AM10N-A, AS32AN02T-A and AS64AN02T-A. For Delta AS PLC applications, match the input or output terminal board to the exact module’s pin table.
For Delta AH PLC connections, also use the complete module and connector designation. Where a module has multiple I/O connectors, identify the channel group assigned to each port. Connector count and 40-contact construction do not directly define the total I/O count.
Differences between 24A, 24B and 24D
| Model | Length | Construction |
|---|---|---|
| UC-ET010-24B | 1 m | Shielded IDC40 ↔ IDC40 |
| UC-ET020-24B | 2 m | Shielded IDC40 ↔ IDC40 |
| UC-ET030-24B | 3 m | Shielded IDC40 ↔ IDC40 |
| UC-ET010-24D | 1 m | Shielded IDC40 ↔ 2 × IDC20 |
UC-ET010-24A also has a 1 m IDC40–IDC40 arrangement; the catalogue specifically identifies 24B as shielded. UC-ET010-24C has a 1 m IDC40–2 × IDC20 arrangement. UC-ET020-24D and UC-ET030-24D are the 2 m and 3 m versions of the shielded two-branch construction.
For 20-pin relay terminal modules such as UB-10-OR16A / DVPAETB-OR16A, review the applicable 24C/24D arrangement. The single IDC40 end of 24B differs from the two IDC20 branches of 24D. The suffix represents more than a length difference.
Pin order, addresses and shield connection
Compare the connector’s pin-1 mark and locking orientation with the equipment diagram. X/Y addresses, S/S, common terminals and supply connections depend on the module. Follow the PLC and terminal-module instructions for shield connection as well.
The AS module manual states that the address markings printed on UB-10-ID32A follow the DVP arrangement. For AS use, apply the corresponding AS mapping table or label. A healthy cable cannot correct channel mapping based on an incorrect terminal label.
Allow sufficient bend clearance and prevent pulling force at the IDC connectors. Avoid crowded routing shared with power cables. Assess allowable load current together with the connected module and terminal-board common-group limits; shielding alone does not define a current rating.
Editor’s Note
Start by recording the devices at both ends: the I/O module and terminal board. A one-metre, forty-pin description alone is insufficient. Verify the module code, board type and 24B suffix together.
Photograph the connector orientation and port before removal. Forcing an incorrectly oriented connector can damage contacts or its housing. If it does not seat properly, inspect it instead of applying more pressure.
With power off and the cable disconnected at both ends, check continuity and adjacent-pin shorts against the model diagram. Gently move each cable entry while measuring. A connection that fails only when moved can cause intermittent field faults.
If several inputs disappear together, inspect the common terminal and field supply as well as individual conductors. If an output LED operates but the load does not, check the terminal board and load circuit separately. Change one variable per test.
For a used cable, inspect IDC housings, latches, the jacket and shield entry points. Follow continuity checks with channel-by-channel testing using suitable hardware and a safe test arrangement. Record which module and board were used.
When moving parts between AS and DVP installations, check terminal address labels separately. Switch off power and record the existing arrangement before changing wiring on a working machine. Verify physical connections before changing programs or parameters.
PDF and related topics
Use the Delta PLC accessories PDF and software files page for cable selection and wiring documents. Further documentation is available under Delta PLC and HMI manuals and Delta user manuals.
Navigation: UC-ET010-24B main page · Delta PLC accessories · Delta PLC models · Used Delta products
External references
Delta PLC/HMI Cable Selection Guide — Chapter 2, Figure 1B · Delta DVP / TP Catalogue — I/O Cable Accessories · Delta AS Series Hardware and Operation Manual — I/O Cables · Delta AS Series Module Manual — UB-10-ID32A Wiring