Delta UC-ET030-24B
Delta UC-ET030-24B
Delta UC-ET030-24B is a 3-metre shielded I/O external-terminal cable with MIL IDC40 connections at both ends. It links a suitable input/output module to an external terminal board. The cable carries module signals to the field connection point; channel count and electrical characteristics depend on the connected hardware.
Verified DVP module-to-terminal combinations
The manufacturer's table shows Delta DVP32SM11N ↔ Delta UB-10-ID32A for inputs and Delta DVP32SN11TN ↔ Delta UB-10-OT32A for outputs using UC-ET030-24B. Both ends use IDC40 connections.
40 contacts do not mean 40 independent I/O channels. Follow common and auxiliary connections in the actual module's pin drawing. Verify terminal-board function, module type and field power together. Review options under Delta external terminals.
AH and AS applications
The cable guide connects the Delta AH32AM10N-5C input module to UB-10-ID32A through the same 24B cable family. Its Delta AS64AM10N-A example shows two separate terminal branches. Determine cable quantity from the module ports actually required.
Do not extend these examples to every AH or AS model. The complete module suffix, IDC40 port, channel group and terminal board must match the same manufacturer drawing. Physical connector fit alone does not establish electrical compatibility.
Differences between 24B, 24A, 24C and 24D
Delta UC-ET010-24B is 1 metre and Delta UC-ET020-24B is 2 metres; both are shielded IDC40-to-IDC40 options. UC-ET030-24B provides 3 metres in that family. Delta UC-ET010-24A is shown separately as a 1-metre ribbon cable.
Delta UC-ET030-24D provides a 3-metre shielded IDC40-to-two-IDC20 connection for the Delta UB-10-OR16A relay-terminal arrangement. Delta UC-ET010-24C is listed as a 1-metre option with the same branching format. Distinguish 24B's single IDC40 terminal end from the two-IDC20 arrangement.
Shielding and cabinet layout
Allow for ducts, turns and maintenance access when assessing the 3-metre route. Avoid pulling on connector housings and check pin-one orientation, keying and retainers. Do not fold the cable sharply at connector exits.
Connect shielding according to the machine's grounding and EMC design. Do not attach it to an arbitrary common terminal. Route the cable appropriately away from motor and drive power wiring. Obtain voltage, channel-current and common-connection limits from the module and terminal documentation.
Power, module and document selection
Review the connected hardware under Delta DVP expansion modules alongside field and system power under Delta DVP power supplies. Replacing the cable does not change I/O type or addressing capacity. Verify the module and terminal power requirements separately.
Start document selection at Delta PLC accessories files. In the PLC/HMI Cable Selection Guide, printed page 2-16 / PDF page 115 shows DVP combinations, and Figure 1B, printed page 2-28 / PDF page 127 shows cable construction. Printed page 49 / PDF page 50 of the 2023 DVP/TP catalogue confirms shielding and length.
Editor's Note
Photograph module and terminal labels together before removal. The cable code alone is insufficient. Keep both ends in the same record to avoid confusing an input module with an output terminal board.
Inspect connectors and pin orientation with power disconnected. Look for bent contacts, broken retainers and incompletely seated IDC housings. Disconnect using the housing and retainers rather than pulling on the cable.
If several channels disappear together, inspect common connections. Check terminal power, common wiring and connector seating together. Use measurements before condemning the cable or module.
Test continuity with both ends disconnected from equipment. Follow pin numbers from the correct viewing direction and avoid bridging adjacent contacts with a probe. Evaluate shield and signal conductors separately.
Begin the final application test with one channel. Observe a known input signal or use a controlled output test load, then complete the relevant channel group. Appearance or a continuity beep alone does not complete field testing.
Related topics
Browse parent groups under Delta DVP / AH I/O cables and Delta PLC accessories, and device documents under Delta PLC and HMI manuals.
External references: Delta PLC/HMI Cable Selection Guide — 2019, English · Delta DVP/TP manufacturer catalogue — 2023, English.