Delta AH expansion modules

Delta AH Expansion Modules

Delta AH expansion modules add digital and analog I/O, temperature measurement, motion control and field communications to a Delta AH500 system. Choose a subcategory by signal type or application. The individual model pages cover channel counts, connection types and technical manuals.

Digital input and output modules

For push buttons, sensors and auxiliary contacts, start with the input voltage. For outputs, check the load type and current per channel. The AH16AM10N-5A accepts 24 V DC inputs and the AH16AM30N-5A accepts AC inputs. Output examples include the AH16AN01R-5A relay module and the AH32AN02T-5C NPN transistor module. When reusing existing field wiring, check whether the model uses a removable terminal block, DB37 or MIL connector.

Analog input and output modules

Use an analog input module such as the AH04AD-5A to read pressure, level or flow transmitters. An analog output module such as the AH04DA-5A supplies a reference to a drive or proportional valve. The AH06XA-5A combines four inputs and two outputs. Match the 4–20 mA or 0–10 V range to the field device and verify channel scaling in the project.

Temperature and motion modules

The AH04PT-5A is an RTD input module and the AH08TC-5A accepts thermocouples. For encoder pulse counting, see the AH02HC-5A high-speed counter. For positioning, the AH05PM-5A uses differential pulse outputs and the AH20MC-5A uses DMCNET. Choose the module to suit the sensor or drive interface.

Communication modules

See the AH10EN-5A for Ethernet, the AH10SCM-5A for serial communications and the AH10COPM-5A for CANopen. On a PROFIBUS DP network, the AH10PFBM-5A is a master module and the AH10PFBS-5A is a slave module. Verify the protocol, station role and CPU support together before selecting a module.

Editor's Note

Before replacing a module, record its full part number, terminal block and slot position.

Use Delta’s compatibility table to check the CPU model, firmware and slot. For AH Motion backplanes, check the supported-module list for the specific Motion CPU.

Include the added modules’ rack consumption and field supply requirements in the AH power supply budget.

In ISPSoft, compare the physical module order and start addresses with the project’s HWCONFIG settings.

During commissioning, verify the signal on one channel or station before checking the remaining points.

PDF manuals and related topics

The Delta AH Series Catalogue contains model and connector tables. See the Delta AH PLC PDF library for hardware, wiring and module manuals. For field wiring, see AH I/O cables and AH external terminals.

More from OtomasyonAVM
Delta AH PLC series · AH Motion CPUs · Delta PLC software · Delta PLC · Used Delta equipment

External reference
Delta AH500 Hardware and Operation Manual — distributor copy


Refine Search