Delta AH16AM10N-5A
Delta AH16AM10N-5A – 16-Point 24 V DC Digital Input Module
The Delta AH16AM10N-5A adds 16 digital inputs rated at 24 V DC to a Delta AH500 PLC rack. This Delta AH digital module has a removable terminal block with inputs 0–15 and S/S common terminals. It reads field devices such as inductive sensors, limit switches and auxiliary contacts.
Input Ratings and Response Time
The nominal input current is 5 mA per channel at 24 V DC, and the input impedance is 4.7 kΩ. The manual specifies an ON threshold above 15 V DC and an OFF threshold below 5 V DC. Response time is 10 ms from OFF to ON and 15 ms from ON to OFF (±10%). The specified maximum input frequency is 50 Hz.
NPN and PNP Sensor Wiring
The module accepts NPN and PNP open-collector signals. Delta’s diagram shows S/S connected to +24 V for NPN sensors and to 0 V for PNP sensors. Match the sensor type to the wiring of the S/S common shared by its channels. Check the field-side 24 V DC sensor supply as well as the rack power supply.
ISPSoft, Addressing and Model Selection
Check the module slot and starting X address in HWCONFIG in ISPSoft. The module occupies 16 bits in the PLC input address space, from Xn.0 to Xn.15. For example, if the starting address is X2.0, terminal 0 maps to X2.0 and terminal 15 maps to X2.15.
For 32 inputs, the AH32AM10N-5A uses a removable terminal block, the AH32AM10N-5B uses DB37, and the AH32AM10N-5C uses a latching MIL connector. For 16 AC field inputs, check the AH16AM30N-5A input ratings.
Editor’s Note
When buying a used card, read the full model code and inspect the removable terminal block and its latch.
If several inputs stop reading at once, measure the field supply and S/S common before replacing the card.
On the bench, test all 16 channels individually with a known-good 24 V DC sensor. Watch both the channel LED and the X bit in ISPSoft.
If the input is missed intermittently, especially with short pulses, compare the signal duration with the input response time.
Record the slot and starting X address before replacement. On the first test, confirm that each field label matches the correct input.
User Manual and PDF Files
AH16AM10N-5A wiring diagram – English PDF. AH500 Hardware and Operation Manual, section 4.7.1, printed page 4-32. Section 4.8.1.3 shows the NPN and PNP examples. For other documents in the series, see the Delta AH PLC PDF files.
Related Topics
64-input AH64AM10N-5C · NPN output AH16AN01T-5A · PNP output AH16AN01P-5A · Delta PLC software
Delta Automation · Delta PLC · Delta AH PLC series · Delta AH expansion modules
External reference · Delta AH Series Catalogue