Delta AH500 Modular PLC and CPU Models
Delta AH500 is a modular PLC family that combines a CPU, power supply and I/O modules on a backplane. The 16 RS2 and EN CPUs in this category offer 32K–384K program steps and support 768–4,352 physical I/O points. Select a CPU based on program capacity, communication ports and backplane count. Other branches are listed in the Delta AH PLC series category.
AH500 CPU selection table
| RS2 CPU | EN CPU | Program capacity | Max. physical I/O |
|---|---|---|---|
| AHCPU500-RS2 | AHCPU500-EN | 32K steps | 768 |
| AHCPU501-RS2 | AHCPU501-EN | 48K steps | 768 |
| AHCPU510-RS2 | AHCPU510-EN | 64K steps | 1,280 |
| AHCPU511-RS2 | AHCPU511-EN | 96K steps | 1,280 |
| AHCPU520-RS2 | AHCPU520-EN | 128K steps | 2,304 |
| AHCPU521-RS2 | AHCPU521-EN | 192K steps | 2,304 |
| AHCPU530-RS2 | AHCPU530-EN | 256K steps | 4,352 |
| AHCPU531-RS2 | AHCPU531-EN | 384K steps | 4,352 |
RS2 models have two DB9 serial ports. EN models have one DB9 serial port and built-in Ethernet. Select RS-232, RS-422 or RS-485 to match the field device. The 500/501 models use one main backplane. The 510/511 support up to one extension backplane, the 520/521 up to three, and the 530/531 up to seven.
Backplane configuration and programming
Pair the CPU with a suitable AH power supply and the expansion modules required by the application. Use digital I/O for discrete sensors and actuators, analog I/O for measurements and reference signals, and communication modules for field networks.
Program the CPU in ISPSoft. Connect the computer with a Mini USB data cable and set up USB (Virtual COM) in COMMGR. EN models can also connect over Ethernet. In HWCONFIG, match the backplanes, module order and I/O addresses to the physical panel.
Redundant PLCs and motion control
For CPU redundancy, see the AH500 redundant PLC category and the AHCPU560-EN2. For EtherCAT-based multi-axis applications, see AH motion controllers.
Manuals and PDF documentation
AH500 CPU specifications and hardware manual · English. Basic and advanced CPU tables are on PDF pages 40–44, the DB9 pinout is on page 199, and USB setup is on pages 333–335. Browse the other manuals under Delta AH PLC PDF files.
Editor’s Note
When buying a used CPU, check the full ordering code and the RS2 or EN suffix on the nameplate.
Inspect the rear backplane connector, Mini USB socket and the port used in your panel.
On the bench, read the CPU model and firmware version in ISPSoft.
Before replacement, back up the accessible project, backplane configuration and communication settings.
Before commissioning, compare the installed modules and I/O addresses with the project.
Related topics
AH temperature and motion modules · Delta PLC software · Delta PLC and HMI manuals
More from Delta · Delta PLC · Delta PLC accessories · Second-hand Delta products
External reference · Delta AH Series Standard CPU