Delta AHCPU511-RS2

Delta AHCPU511-RS2 AH500 PLC CPU Module

The Delta AHCPU511-RS2 is an advanced AH500 CPU in the Delta AH PLC family. It provides 96K program steps and 2 MB of function block memory. A system with one main backplane and one extension backplane supports up to 1,280 physical I/O points.

The AHCPU510-RS2 is a basic CPU with 64K program steps. For built-in Ethernet with the same 96K capacity, see the AHCPU511-EN. For higher program capacity and more expansion, see the AHCPU521-RS2.

Serial ports, Mini USB and SD card

COM1 and COM2 are DB9 serial ports. Delta documents RS-232, RS-422 and RS-485 wiring for these ports. Check the project’s port mode and the manual’s pinout before preparing the cable. The CPU also has a Mini USB programming port and an SD card slot for backup. See AH communication modules for additional network interfaces.

ISPSoft, COMMGR and programming cable

Use ISPSoft and COMMGR for programming. Connect the computer to the CPU with a Mini USB data cable. Once the Delta USB driver is installed, select the COM port assigned by the operating system under USB (Virtual COM) in COMMGR. Select that driver in ISPSoft’s communication settings. See Delta PLC software for the engineering tools.

Backplane, power supply and I/O configuration

Use HWCONFIG in ISPSoft to match the CPU, backplane and module order to the physical panel. See AH expansion modules, AH power supplies, AH digital modules and AH analog modules for system selection.

Manual and PDF documentation

AHCPU511-RS2 specifications and connection manual · In the English AH500 manual, specifications are on PDF pages 42–43, the DB9 pinout is on page 199, and USB setup is on pages 333–335. Browse the series documentation under Delta AH PLC PDF files.

Editor’s Note

When buying used, verify the AHCPU511-RS2 nameplate and inspect the rear backplane connector.
Check the Mini USB socket, both DB9 ports and the SD card slot individually.
On the bench, read the CPU model and firmware version in ISPSoft.
Before replacement, back up the accessible program, backplane configuration and serial port settings.
If USB connects but a field device fails to respond, first check the COM1/COM2 selection, serial mode and DB9 cable pinout.

Related topics

Other serial-port AH500 CPUs include the AHCPU501-RS2, AHCPU520-RS2, AHCPU530-RS2 and AHCPU531-RS2.

More from Delta · Delta PLC · Delta PLC accessories · Delta PLC and HMI manuals · Second-hand Delta products

External reference · Delta AH500 Hardware and Operation Manual