Delta AHCPU510-RS2
Delta AHCPU510-RS2 – 64K-Step AH500 PLC CPU
The Delta AHCPU510-RS2 is a standard rack-mounted PLC CPU in the Delta AH500 family. It has a program capacity of 64K steps and 32,768 D data registers. The CPU has two DB9 serial ports, a Mini USB programming port and an SD card slot.
It suits machine and process control panels with serial HMIs, drives and field devices. One main backplane and one extension backplane can accommodate up to 20 modules and up to 1,280 physical I/O points, depending on module selection. Use AH digital modules for discrete signals and AH analog modules for voltage and current signals.
Serial connections and programming
COM1 and COM2 are DB9 serial ports. Delta’s manual gives separate pin assignments for RS-232, RS-422 and RS-485. When connecting a Modbus RTU device, check the port mode, station address, baud rate and parity at both ends. See AH communication modules for additional network options.
Mini USB, ISPSoft and COMMGR Connect the computer to the CPU with a Mini USB data cable. Select the COMMGR connection, then use ISPSoft for program transfer or online monitoring. Connection drawings are in section 1.14.4 of the Delta PLC/HMI Cable Selection Guide.
Backplane and backup Check the physical module order and I/O addresses in ISPSoft HWCONFIG. Select the backplane together with the AH expansion modules, extension cable and AH rack power supply. Delta specifies a standard SD card of up to 2 GB for this basic CPU group.
PDF manual Delta AH500 Hardware and Operation Manual (English). See 2.2.1 for CPU capacity, 4.6.1 for DB9 wiring and 7.1.2 for SD card specifications. See Delta AH PLC PDF Files for related documentation.
Editor’s Note
On a used CPU, confirm the full AHCPU510-RS2 order code and inspect both DB9 sockets and the rear backplane connector.
Before replacing a CPU, back up the hardware configuration, serial settings and retained process values along with the program.
On the bench, connect through Mini USB. Test COM1 and COM2 individually in the communication modes required by the machine.
If the extension rack is missing, check rack power, the extension cable and the HWCONFIG module order before replacing a module.
Before restoring from an SD card, verify the date of the backup and the CPU’s DIP-switch settings.
Related Topics
Related CPUs The AHCPU500-RS2 offers 32K steps, the AHCPU511-RS2 offers 96K, and the AHCPU520-RS2 offers 128K. For 64K steps with built-in Ethernet, see the AHCPU510-EN. For small stand-alone panel control tasks, see the Derell DLC-R1210-2I-R-A smart relay.