Delta AHCPU521-RS2

Delta AHCPU521-RS2 PLC CPU – 192K Steps, Dual Serial Ports

The Delta AHCPU521-RS2 is an advanced CPU for the modular Delta AH500 series. It provides 192K program steps, two DB9 serial ports, a Mini USB programming port and an SD card slot. On machines with serial HMIs, drives and instruments, one port can serve the operator panel and the other the field network.

Model selection. The AHCPU520-RS2 offers 128K steps with the same rack and physical I/O limits. The AHCPU521-EN offers 192K steps with one Ethernet port and one serial port. See the AHCPU511-RS2 for systems that need one expansion rack, or the AHCPU531-RS2 for systems that need up to seven expansion racks.

User manual

AHCPU521-RS2 Hardware and Operation Manual (PDF) · English. PDF pages 42–44 cover CPU capacity and ports. Pages 45–46 show the front panel and the LED indicators. HWCONFIG CPU settings start on PDF page 382, and Appendix A covers the USB driver. All Delta AH PLC PDF files.

Program memory, racks and I/O

Memory. Program capacity is 192K steps, and function block memory is 4 MB. The CPU provides 98,304 data registers, from D0 to D98303, and an SD 1.0 card slot.

Rack capacity. The system supports one main rack and up to three expansion racks. Delta specifies up to 36 modules and 2,304 physical I/O points. The actual input and output count depends on the installed digital modules and analog modules. See AH expansion modules for rack configuration.

Power supply. The CPU mounts in the CPU slot on the main backplane. The AHPS05-5A takes 100–240 V AC and the AHPS15-5A takes 24 V DC. Base the power budget for each rack on the combined load of its installed modules. Delta AH power supplies.

COM1, COM2 and ISPSoft connection

Serial communication. COM1 and COM2 are DB9 ports configurable for RS-232, RS-485 or RS-422. Match the port mode, pinout, station address, bit rate and parity to the connected device. For PLC Link over RS-485, configure this advanced CPU in ISPSoft HWCONFIG. If the project requires additional serial ports, see the AH10SCM-5A and other AH communication modules.

Programming. Connect the PC to the CPU with a data-capable Mini USB cable. Delta’s AH500 cable guide shows the UC-PRG015-01A (1.5 m) and UC-PRG030-01A (3 m). After installing the CPU’s USB driver, set up the connection in COMMGR. Select AHCPU521-RS2 in the ISPSoft project and check the rack layout in HWCONFIG. Delta PLC software.

Editor’s Note

When buying a used CPU, check the 521-RS2 nameplate, both DB9 sockets and the backplane connector.

On the bench, use Mini USB to read the CPU model and firmware version. Then test the two serial ports separately.

Before replacement, back up the working PLC program, HWCONFIG settings and any retentive D registers the application needs.

If BUS FAULT lights up, read the ISPSoft system log first. Then compare the actual rack order, expansion cable and rack power supplies with the project.

If the CPU runs and the HMI or drive fails to respond, confirm the COM port first. Then match the port mode, station address, bit rate and parity to the connected device.

Related topics

Delta AH PLC series · Delta PLC accessories · Delta PLC models · Second-hand Delta.

External references

Delta AH500 advanced CPU specifications · Delta PLC/HMI Cable Selection Guide, section 1.14.4.